BPG is committed to discovery and dissemination of knowledge
Minireviews
Copyright: ©Author(s) 2026. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial (CC BY-NC 4.0) license. No commercial re-use. See permissions. Published by Baishideng Publishing Group Inc.
World J Diabetes. Dec 15, 2026; 17(12): 125608
Published online Dec 15, 2026. doi: 10.4239/wjd.125608
Once-weekly basal insulin analogs in type 2 diabetes: Pharmacological rationale, clinical evidence, and practical considerations for implementation
Melike Yakut
Melike Yakut, Department of Internal Medicine, Eskisehir Cifteler State Hospital, Eskisehir 26700, Türkiye
Author contributions: Yakut M contributed to the research design, the literature review, the data analysis, and the manuscript writing.
AI contribution statement: AI tools (Claude, Anthropic; ChatGPT, OpenAI) were used solely for language editing, reference formatting, and English language refinement during manuscript preparation. No AI tool was used to generate research data, perform statistical analysis, produce figures or tables, interpret results, or formulate conclusions. All scientific content, clinical interpretations, data analyses, and conclusions are the work of the author, who critically reviewed all AI-assisted text and takes full responsibility for the accuracy, originality, and integrity of the manuscript.
Conflict-of-interest statement: The author reports no relevant conflicts of interest for this article.
Corresponding author: Melike Yakut, Department of Internal Medicine, Eskisehir Cifteler State Hospital, No. 2 İbrahim Dede Caddesi, Eskisehir 26700, Türkiye. melikeyakut95@gmail.com
Received: July 14, 2026
Revised: August 25, 2026
Accepted: November 2, 2026
Published online: December 15, 2026
Processing time: 138 Days and 23.8 Hours
Abstract

Many patients with type 2 diabetes require insulin, but adherence to daily basal regimens is frequently suboptimal because of injection burden, needle anxiety, and lifestyle disruption. Two molecularly distinct once-weekly basal insulin analogs have completed phase 3 evaluation. Insulin icodec achieves prolonged action through fatty diacid-mediated albumin binding (half-life approximately 196 hours), whereas insulin efsitora alfa (half-life 10-14 days) uses immunoglobulin fragment crystallizable-domain (Fc-domain) fusion with neonatal Fc-receptor recycling. Across the six ONWARDS trials, icodec was non-inferior to daily comparators and additionally superior in insulin-naïve type 2 diabetes. Across the five QWINT trials, efsitora was non-inferior without demonstrating superiority; QWINT-1 showed that a simplified fixed-step regimen can match titrated daily glargine U100 while reducing the median number of dose adjustments from eight to two. Both agents increased hypoglycemia in type 1 diabetes. The IcoSema coformulation was non-inferior to basal-bolus therapy for glycated hemoglobin and superior for weight, insulin dose, and hypoglycemia, at the cost of more gastrointestinal adverse events. No head-to-head trial has compared icodec with efsitora, and long-term cardiovascular, real-world adherence, and cost-effectiveness data are unavailable. Implementation requires a modified titration cadence, awareness of loading-dose effects, and structured sick-day and perioperative planning.

Keywords: Insulin icodec; Insulin efsitora alfa; Type 2 diabetes; Once-weekly insulin; Basal insulin; Glycemic control; Hypoglycemia; Medication adherence; IcoSema; Clinical practice

Core Tip: Once-weekly basal insulin analogs reduce injection frequency from 365 to 52 per year. Insulin icodec, approved for type 2 diabetes in several jurisdictions including the European Union, Canada, and the United States, achieved superiority over daily comparators in insulin-naïve patients across the ONWARDS program. In QWINT-1, insulin efsitora alfa showed that a simplified fixed-step weekly regimen can match titrated daily insulin. Both agents increase hypoglycemia risk in type 1 diabetes. No head-to-head comparison exists. Implementation requires modified titration intervals, loading-dose awareness, and proactive sick-day planning.

Write to the Help Desk