©The Author(s) 2016.
World J Radiol. Apr 28, 2016; 8(4): 378-389
Published online Apr 28, 2016. doi: 10.4329/wjr.v8.i4.378
Published online Apr 28, 2016. doi: 10.4329/wjr.v8.i4.378
Table 2 Intraoperative details of patients of study group and control group for entire study population
| Parameters | Study group, n = 26 | Control group, n = 28 | P value |
| Intraoperative blood loss (mL) | |||
| Minimum | 250 | 800 | |
| Maximum | 2900 | 6000 | < 0.0015 |
| Median | 1300 | 1800 | |
| Intraoperative blood transfusion (mL) | |||
| Minimum | 0 | 700 | |
| Maximum | 1400 | 8400 | < 0.0001 |
| Median | 700 | 1400 | |
| Surgical time (min) | |||
| Minimum | 115 | 145 | > 0.14 |
| Maximum | 450 | 450 | |
- Citation: Jha R, Sharma R, Rastogi S, Khan SA, Jayaswal A, Gamanagatti S. Preoperative embolization of primary bone tumors: A case control study. World J Radiol 2016; 8(4): 378-389
- URL: https://www.wjgnet.com/1949-8470/full/v8/i4/378.htm
- DOI: https://dx.doi.org/10.4329/wjr.v8.i4.378