Table 1 An ASTRO clinical practice guideline for brain metastases radiotherapy
KQ
Population
Intervention
Comparator
Outcomes
1What are the indications for SRS alone for patients with intact BM?
Patients with intact BMObservation
WBRT
SRSIntracranial control; progression-free survival; overall survival; neurocognitive function; patient-reported outcomes
2What are the indications for observation, preoperative SRS or WBRT in patients with resected BM?
Patients with resected BMObservation
WBRT
SRSIntracranial control; progression-free survival; overall survival; neurocognitive function; patient-reported outcomes
3What are the indications for WBRT for patients with intact BM?
Patients with intact BMObservation
WBRT
Conventional WBRT; HA-WBRT; HA-WBRT plus memantineIntracranial control; progression-free survival; overall survival; neurocognitive function; patient-reported outcomes
4What are the risks of symptomatic radionecrosis with WBRT and/or SRS for patients with BM?
Patients with BMWBRTSRSSymptomatic radionecrosis; other adverse effects
Table 2 Comparison of different imaging modalities in brain metastases target delineation
Imaging modality
Advantages
Limitations
Clinical applications in BM radiotherapy
T1WI + CStandard reference; excellent for enhancing lesions; widely availableVascular enhancement can obscure cortical/CSF-adjacent lesions; signal interference from blood vesselsPrimary sequence for GTV delineation; standard for response assessment
T2-FLAIRSuppresses CSF signal; excellent for edema visualization; detects non-enhancing tumorNo contrast enhancement; may miss small lesionsAssessing peritumoral edema; visualizing non-enhancing tumor components
T2-FLAIR + CCSF suppression; superior detection of cortical/meningeal lesions; high sensitivity to low-dose contrast; reduces vascular interferenceVariable availability; technical standardization lacking; limited evidence base for target delineationDelineating lesions near CSF/cortex; detecting leptomeningeal disease; possible role in target delineation
CTFast; widely available; excellent for bone anatomy; essential for dose calculationPoor soft tissue contrast; low sensitivity for small metastasesSimulation and localization; electron density mapping for dose calculation
PET-CTMetabolic information; distinguishes active tumor from necrosis/edemaLimited spatial resolution; higher cost; radiation exposureProblem-solving in equivocal cases; detecting active disease
DCE-MRIAssesses vascular permeability; biological informationLonger acquisition; specialized processing; not standard in routine practiceResearch applications; understanding tumor biology
DSC-MRIAssesses perfusion and angiogenesis; helps differentiate RN from TPRequires specialized software; prone to artifactsDifferentiating radiation necrosis from tumor progression
Table 3 Summary of key clinical studies of contrast-enhanced T2-fluid-attenuated inversion recovery sequence in brain metastases
Ref.
Population
Sample size
Contrast agent/dose
Acquisition setting
Comparator
Primary outcome
Key limitations
Jin et al[33]Patients with suspected BM82Half-doseDiagnosticStandard-dose T1WI + CLesion detection rate; contrast-to-noise ratio comparisonSingle-center; no radiotherapy contouring endpoint
Ahn et al[31]Patients with small BM121Double-dose DiagnosticConventional 3D T1WI + CDetection sensitivity for small BMDiagnostic cohort only; no radiotherapy application
Sun et al[18]Lung cancer patients with BM156Standard-dose DiagnosticT1WI + C aloneOverall lesion detection rateDiagnostic study; no target delineation analysis
Heyn et al[123]BM patients post-radiotherapy98Standard-dose Diagnostic follow-upDSC-MRIDifferentiation of radiation necrosis vs tumor progressionRetrospective; single-center
Ohira et al[53]BM patients undergoing SRS41Standard-dose Radiotherapy simulationCT simulationGeometric distortion and dosimetric impactFocused on distortion, not contour accuracy