Basic Study
Copyright ©The Author(s) 2021.
World J Gastrointest Surg. Jun 27, 2021; 13(6): 563-573
Published online Jun 27, 2021. doi: 10.4240/wjgs.v13.i6.563
Table 1 Comparison of baseline characteristics of enrolled mock lesions and operators between two groups

Hybrid ESD (n = 32)
Conventional ESD (n = 32)
P value
Location, n (%)1
Upper or middle third15 (46.8)15 (46.9)
Lower third17 (53.1)17 (53.1)
Position, n (%)1
Lessor curvature16 (50)16 (50)
Others16 (50)16 (50)
Operator skills1
Trainee16 (50)16 (50)
Expert16 (50)16 (50)
Table 2 Comparison of treatment outcomes of endoscopic submucosal dissection between two groups

Hybrid ESD (n = 32)
Conventional ESD (n = 32)
P value
ESD procedure time, min
Median (IQR)8.3 (6.6-12.0)16.2 (9.5-20.1)< 0.001a
En bloc resection, n (%)32 (100)32 (100)
Complete resection, n (%)30 (93.8)28 (87.5)0.67
Perforation, n (%)0 (0)1 (3.1)1
Mucosal incision time, min
Median (IQR)3.5 (2.5-5.5)4.2 (2.7-5.3)0.82
Submucosal dissection time, min
Median (IQR)5.2 (3.7-6.6)10.4 (7.0-15.1)< 0.001a
Resected specimen size, mm2
Median (IQR)254.3 (201-282.6)247.3 (201.0-254.3)0.44
Circumferential length, mm
Median (IQR)56.5 (50.3-59.7)55.8 (50.3-56.5)0.49
Mucosal incision speed, mm/min
Median (IQR)15.3 (10.8-20.1)13.0 (10.0-20.3)0.67
Submucosal dissection speed, mm2/min
Median (IQR)43.7 (34.6-64.6)23.8 (17.0-30.1)< 0.001a
Total injection volume, mL
Median (IQR)8.3 (6.6-12.0)16.2 (9.5-20.1)< 0.001a
Injection volume during mucosal incision, mL
Median (IQR)5.0 (4.5-7.0)6.0 (4.8-7.6)0.40
Injection volume during submucosal dissection, mL
Median (IQR)1.5 (1.0-2.1)3.0 (2.4-5.6)< 0.001a
Table 3 Univariate and multivariate analysis for the factors associated with the difficulty of endoscopic submucosal dissection including long procedure time (≥ 20 min), incomplete resection and perforation
No. of patientsNo. of eventsUnivariate
Multivariate
OR
95%CI
P value
OR
95%CI
P value
Location
L3461Ref0.251Ref0.72
U or M3092.00.62-6.51.320.28-6.3
Position
G or A or P3231Ref0.01a1Ref0.004a
Lessor32125.81.4-23.29.92.0-71.4
Size
< 250 mm23161Ref0.451Ref0.33
≥ 250 mm23391.60.48-5.12.10.48-10.1
Operator skill
Expert3241Ref0.051Ref0.015a
Trainee32113.71.0-13.16.21.4-37.7
Method
Hybrid ESD3231Ref0.01a1Ref0.002a
Conventional ESD32125.81.4-23.210.12.2-67.5

  • Citation: Esaki M, Ihara E, Hashimoto N, Abe S, Aratono C, Shiga N, Sumida Y, Fujii H, Haraguchi K, Takahashi S, Iwasa T, Nakano K, Wada M, Somada S, Nishioka K, Minoda Y, Ogino H, Ogawa Y. Efficacy of hybrid endoscopic submucosal dissection with SOUTEN in gastric lesions: An ex vivo porcine model basic study. World J Gastrointest Surg 2021; 13(6): 563-573