Retrospective Study
Copyright ©The Author(s) 2016.
World J Gastrointest Endosc. Apr 10, 2016; 8(7): 338-343
Published online Apr 10, 2016. doi: 10.4253/wjge.v8.i7.338
Table 1 Currently available stents in the United States
StentManufacturerMaterialDiameter body/flare (mm)Length (cm)Covering
Alimaxx-EAlveolusNitinol18/227/10/12FC with antimigration struts
Esophageal Z-stentCookStainless steel18/258/10/12/14PC
EvolutionCookNitinol20/258/10/12.5/15PC
Flamingo WallstentBoston ScientificStainless steel20/3012/14PC
Gianturco-ZCookStainless steel18/258/10/12/14FC
Niti-STaewong MedicalNitinol16/208/10/12/14FC
18/23
20/25
Niti-S; double layeredTaewong MedicalNitinol18/269/12/15FC with additional uncovered outer nitinol wires
Niti-S; single layeredTaewong MedicalNitinol18/269/12/15FC
PolyflexBoston ScientificPolyester16/209/12/15FC
18/23
21/28
SX-ELLAElla-CSNitinol20/258.5/11/13.5/15FC with antimigration ring
UltraflexBoston ScientificNitinol18/2310/12/15PC
23/28
WallflexBoston ScientificNitinol18/2310/12/15PC/FC
23/28
Table 2 Overall demographics in patients having self-expanding esophageal metal stents/self-expanding esophageal plastic stents placed for malignant or benign esophageal conditions from January 2005 to April 2012
Overall (n = 43)nHw (n = 25)AA (n = 15)Other (n = 3)
Mean age (yr)60.257.760.4801
% male85.18080100
Table 3 Patient characteristics based on stent type placed
SEMS (n = 30)SEPS (n = 13)P value
Mean age (yr ± SD)59.6 ± 14.8761.7 ± 9.950.645
% male83.3%76.9%0.681
Race/ethnicity, n (%)AA: 9 (30%)AA: 6 (46%)0.704
nHw: 18 (60%)nHw: 7 (54%)
Other: 3 (10%)Other: 0
Malignant esophageal lesion, n (%)25 (83.3%)10 (76.9%)0.681
Esophageal lesion location, n (%)Upper third: 0Upper third: 1 (7.7%)0.15
Middle third: 9 (30%)Middle third: 6 (46.2%)
Lower third: 21 (70%)Lower third: 6 (46.2%)
Comorbid diseases, n (%)HTN: 16 (53.3%)HTN: 6 (46.2%)0.747
CAD: 7 (23.3%)CAD: 2 (15.4%)0.699
COPD: 5 (16.7%)COPD: 1 (7.7%)0.649
DM: 11 (36.7%)DM: 3 (23.1%)0.491
Table 4 Placement and outcome comparisons between self-expanding esophageal metal stents and self-expanding esophageal plastic stents
SEMS (n = 30)SEPS (n = 13)P value
Initial placement procedure time (min, mean ± SD)33.17 ± 16.8835.85 ± 27.390.696
Dilation required prior to stent placement023%0.023
Complications, n (%)7 (23%)3 (23%)1
Time to first complication (n)< 30 d: 6< 30 d: 21
> 30 d: 1> 30 d: 1
In-hospital mortality (%)7%8%1
Re-intervention required (%)20%23%1
30 d survival after procedure (%)95%80%0.251
Length of stay (d, mean ± SD)11.47 ± 12.7812.15 ± 16.210.883