Observational Study
Copyright ©The Author(s) 2017.
World J Gastroenterol. Dec 21, 2017; 23(47): 8405-8414
Published online Dec 21, 2017. doi: 10.3748/wjg.v23.i47.8405
Table 3 Endoscopy and polypectomy technical details
Characteristicsn (%)
Sedation302 (98.1)
University Hospital251 (81.5)
Endoscopist Staff268 (87)
Number of polyps resected
1205 (66.6)
255 (17.9)
320 (6.5)
48 (2.6)
57 (2.3)
> 513 (4.2)
Cautery settings
Endocut236 (76.6)
Hemorrhage prophylaxis219 (71.1)
One technique149 (68)
Two or more70 (32)
Prophylactic technique
Injection alone119 (54.3)
Clips16 (7.3)
Clips + injection60 (27.4)
Endoloop9 (4.1)
Endoloop + injection5 (2.3)
APC5 (2.3)
APC + injection2 (0.9)
APC+ clips + injection3 (1.4)

  • Citation: Córdova H, Argüello L, Loras C, Naranjo Rodríguez A, Riu Pons F, Gornals JB, Nicolás-Pérez D, Andújar Murcia X, Hernández L, Santolaria S, Leal C, Pons C, Pérez-Cuadrado-Robles E, García-Bosch O, Papo Berger M, Ulla Rocha JL, Sánchez-Montes C, Fernández-Esparrach G. Rate of adverse events of gastroduodenal snare polypectomy for non-flat polyp is low: A prospective and multicenter study. World J Gastroenterol 2017; 23(47): 8405-8414