BPG is committed to discovery and dissemination of knowledge
Retrospective Cohort Study
Copyright: ©Author(s) 2026. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial (CC BY-NC 4.0) license. No commercial re-use. See permissions. Published by Baishideng Publishing Group Inc.
World J Gastroenterol. Dec 7, 2026; 32(45): 121243
Published online Dec 7, 2026. doi: 10.3748/wjg.121243
Association of smaller-diameter underdilation of transjugular intrahepatic portosystemic shunt stents with improved long-term survival: A propensity score-matched study
Wen-Qing Zhang, Ke-Jia Li, Fan Yang, Guang-Jin Jiang, Lei Zhang, Hua Jiang, Hao Guo, Song-Wei Li
Wen-Qing Zhang, Fan Yang, Lei Zhang, Hua Jiang, Song-Wei Li, Department of Interventional Radiology, The Second Affiliated Hospital of Kunming Medical University, Kunming 650101, Yunnan Province, China
Ke-Jia Li, Department of Pharmacy, The Second Affiliated Hospital of Kunming Medical University, Kunming 650101, Yunnan Province, China
Guang-Jin Jiang, Department of Radiology, The Second People’s Hospital of Baoshan, Baoshan 678000, Yunnan Province, China
Hao Guo, Department of Radiology, The People’s Hospital of Simao District (Pu’er Central Hospital), Pu’er 665000, Yunnan Province, China
Co-first authors: Wen-Qing Zhang and Ke-Jia Li.
Author contributions: Zhang WQ performed the statistical analysis and wrote the original manuscript; Li KJ participated in the study design, provided postoperative medication guidance, revised the manuscript according to reviewers’ comments, and obtained the funding support; Yang F, Jiang GJ, Zhang L, and Guo H collected the data and conducted follow-up; Jiang H editing the figure; Li SW designed the study, supervised the research, performed the statistical analysis, reviewed the manuscript, and obtained the funding support. Zhang WQ and Li KJ contributed equally to the work as co-first authors. All authors have read and approve the final manuscript.
AI contribution statement: AI tools (specifically DeepSeek, Gemini, ChatGPT) were used solely for language polishing and code assistance. No AI tool was involved in the generation of research data, interpretation of results, or formulation of conclusions. All AI-generated outputs were critically reviewed and revised by the authors.
Supported by Scientific Research Fund of Yunnan Provincial Department of Education, No. 2024J0233; and Yunnan Fundamental Research Kunming Medical University Joint Projects, No. 202501AY070001-085.
Institutional review board statement: The study was reviewed and approved by the Ethics Committee of the Second Affiliated Hospital of Kunming Medical University (Approval No. PJ-KY-2026-12).
Informed consent statement: According to the Declaration of Helsinki, informed consent requirements were waived due to the retrospective nature of the study design.
Conflict-of-interest statement: All the authors report no relevant conflicts of interest for this article.
STROBE statement: The authors have read the STROBE Statement-checklist of items, and the manuscript was prepared and revised according to the STROBE Statement-checklist of items.
Data sharing statement: No additional data are available.
Corresponding author: Song-Wei Li, MD, Associate Professor, Department of Interventional Radiology, The Second Affiliated Hospital of Kunming Medical University, No. 374 Dianmian Avenue, Wuhua District, Kunming 650101, Yunnan Province, China. lisongwei@kmmu.edu.cn
Received: March 27, 2026
Revised: May 19, 2026
Accepted: June 29, 2026
Published online: December 7, 2026
Processing time: 202 Days and 14.7 Hours
Abstract
BACKGROUND

In clinical practice, the choices of stent diameter and dilation strategy during the transjugular intrahepatic portosystemic shunt (TIPS) procedure are critical factors that influence patient outcomes, necessitating a balance between adequate portal decompression and preventing complications. Therefore, optimizing stent implantation strategies is urgently needed to enhance patient outcomes.

AIM

To evaluate the impact of underdilating an 8-mm expanded polytetrafluoroethylene (ePTFE)-covered stent to ≤ 6 mm vs ≥ 7 mm during the TIPS procedure on postoperative overt hepatic encephalopathy (OHE), rebleeding, stent dysfunction, and survival.

METHODS

This retrospective cohort study included 192 patients who underwent TIPS with an 8-mm ePTFE-covered stent in a tertiary hospital between August 1, 2016, and December 31, 2020. Patients were divided into two groups based on underdilation diameter (≤ 6 mm vs ≥ 7 mm); subsequent 1:1 propensity score matching (PSM) yielded 78 patients per group. The primary endpoints were overall survival (OS) and OHE incidence, and the secondary endpoints included variceal rebleeding and shunt dysfunction. Kaplan-Meier survival analysis, the log-rank test, and multivariable Cox regression analysis were used to assess the effect of stent underdilation on post-TIPS survival.

RESULTS

Among the 192 patients, 49 developed OHE within 1 year after TIPS. During follow-up, 48 patients died, 24 experienced rebleeding, and 15 developed shunt dysfunction. Before PSM, the incidences of OHE in the ≤ 6 mm and ≥ 7 mm groups were 24.4% and 26.5%, respectively (P = 0.748); after PSM, these incidences were 21.8% and 28.2% (P = 0.355). Mortality rates were lower in the ≤ 6 mm group than in the ≥ 7 mm group both before (16.7% vs 32.4%, P = 0.012) and after matching (14.1% vs 34.6%, P = 0.003). No significant differences were observed between the groups regarding rebleeding rates (before PSM: 14.4% vs 10.8%, P = 0.444; after PSM: 14.1% vs 11.5%, P = 0.632) or shunt dysfunction rates (before PSM: 5.6% vs 9.8%, P = 0.274; after PSM: 5.1% vs 11.5%, P = 0.148). Ordinal logistic regression demonstrated no significant association between the underdilation strategy and OHE severity (odds ratio = 0.683, 95% confidence interval: 0.194-2.404, P = 0.552). Kaplan-Meier analysis after PSM showed improved OS in the ≤ 6 mm group (log-rank P = 0.015). Multivariable Cox regression identified underdilation to ≤ 6 mm as an independent protective factor for OS (hazard ratio = 0.422, 95% confidence interval: 0.203-0.877, P = 0.021).

CONCLUSION

Underdilating an 8-mm ePTFE-covered stent during the TIPS procedure does not affect postoperative rebleeding or shunt dysfunction. Compared with underdilation to ≥ 7 mm, underdilation to ≤ 6 mm does not decrease the incidence of postoperative OHE but reduces mortality risk, conferring a substantial survival benefit.

Keywords: Transjugular intrahepatic portosystemic shunt; Underdilation; Expanded polytetrafluoroethylene-covered stent; Overt hepatic encephalopathy; Overall survival; Rebleeding; Shunt dysfunction; Propensity score matching

Core Tip: In our study, underdilating an 8-mm expanded polytetrafluoroethylene-covered stent to ≤ 6 mm vs ≥ 7 mm during transjugular intrahepatic portosystemic shunt showed no significant differences regarding the incidences of postoperative rebleeding, shunt dysfunction, and overt hepatic encephalopathy; however, it substantially reduced the mortality risk in the ≤ 6 mm group. Underdilating the stent to ≤ 6 mm appears to recalibrate the risk-benefit balance during transjugular intrahepatic portosystemic shunt with 8-mm expanded polytetrafluoroethylene-covered stents, yielding superior mid-to-long-term survival benefits.