Rapid Communication
Copyright ©2007 Baishideng Publishing Group Co., Limited. All rights reserved.
World J Gastroenterol. May 28, 2007; 13(20): 2841-2845
Published online May 28, 2007. doi: 10.3748/wjg.v13.i20.2841
Radiofrequency ablation in a porcine liver model: Effects of transcatheter arterial embolization with iodized oil on ablation time, maximum output, and coagulation diameter as well as angiographic characteristics
Motoki Nakai, Morio Sato, Shinya Sahara, Nobuyuki Kawai, Hirohiko Tanihata, Masashi Kimura, Masaki Terada
Motoki Nakai, Department of Radiology, Hidaka General Hospital, 116-2 Sono, Gobo Shi, Wakayama 644-8655, Japan
Morio Sato, Shinya Sahara, Nobuyuki Kawai, Hirohiko Tanihata, Masashi Kimura, Masaki Terada, Department of Radiology, Wakayama Medical University 811-1, Kimiidera, Wakayama Shi, Wakayama 641-8510, Japan
Author contributions: All authors contributed equally to the work.
Correspondence to: Motoki Nakai, Department of Radiology, Hidaka General Hospital, 116-2 Sono, Gobo Shi, Wakayama 644-8655, Japan. nakai@hidakagh.gobo.wakayama.jp
Telephone: +81-738-221111 Fax: +81-738-232253
Received: February 10, 2007
Revised: April 3, 2007
Accepted: April 13, 2007
Published online: May 28, 2007
Abstract

AIM: To evaluate the effects of combined radiofrequency ablation and transcatheter arterial embolization with iodized oil on ablation time, maximum output, coagulation diameter, and portal angiography in a porcine liver model.

METHODS: Radiofrequency ablation (RFA) was applied to in vivo livers of 10 normal pigs using a 17-gauge 3.0 cm expandable LeVeen RF needle electrode with or without transcatheter arterial embolization (TAE) with iodized oil (n = 5). In each animal, 2 areas in the liver were ablated. Direct portography was performed before and after RFA. Ablation was initiated at an output of 30 W, and continued with an increase of 10 W per minute until roll-off occurred. Ablation time and maximum output until roll-off, and coagulated tissue diameter were compared between the 2 groups. Angiographic changes on portography before and after ablation were also reviewed.

RESULTS: For groups with and without TAE with iodized oil, the ablation times until roll-off were 320.6 ± 30.9 seconds and 445.1 ± 35.9 seconds, respectively, maximum outputs were 69.0 ± 7.38 W and 87.0 ± 4.83 W and maximal diameters of coagulation were 41.7 ± 3.85 mm and 33.2 ± 2.28 mm. Significant reductions of ablation time and maximum output, and significantly larger coagulation diameter were obtained with RFA following TAE with iodized oil compared to RFA alone. Portography after RFA following TAE with iodized oil revealed more occlusion of the larger portal branches than with RFA alone.

CONCLUSION: RFA following TAE with iodized oil can increase the volume of coagulation necrosis with lower output and shorter ablation time than RFA alone in normal pig liver tissue.

Keywords: Liver, Radiofrequency ablation, Transcatheter arterial embolization, Iodized oil, Angiography, Hepatocellular carcinoma