Basic Research
Copyright ©The Author(s) 2005. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Gastroenterol. Aug 28, 2005; 11(32): 4974-4978
Published online Aug 28, 2005. doi: 10.3748/wjg.v11.i32.4974
Time-dependent viscoelastic properties along rat small intestine
James B Smith, Jing-Bo Zhao, Yan-Ling Dou, Hans Gregersen
James B Smith, Yan-Ling Dou, Hans Gregersen, Institute of Experimental Clinical Research, Aarhus University, Denmark
Jing-Bo Zhao, Hans Gregersen, Center of Excellence in Visceral Biomechanics and Pain, Aalborg Hospital and Center of SMI, Aalborg University, Aalborg, Denmark
Yan-Ling Dou, Department of Gastroenterology, China-Japan Friendship Hospital, Beijing 100029, China
Author contributions: All authors contributed equally to the work.
Supported by the Karen Elise Jensens Foundation and the Danish Technical Research Council
Correspondence to: Dr. Hans Gregersen, MD, MSc, Director and Professor, Center of Excellence in Visceral Biomechanics and Pain, Aalborg Hospital, Hobrovej 42 A, Aalborg DK-9100, Denmark. hag@smi.auc.dk
Telephone: +45-99322064 Fax: +45-98133060
Received: December 1, 2004
Revised: January 23, 2005
Accepted: January 26, 2005
Published online: August 28, 2005
Abstract

AIM: To measure the time-dependent (viscoelastic) behavior in the change of the small intestinal opening angle and to test how well the behavior could be described by the Kelvin model for a standard linear solid.

METHODS: Segments from the duodenum, jejunum, and ileum were harvested from 10 female Wistar rats and the luminal diameter, wall thickness, and opening angle over time (θ(t)) were measured from rings cut from these segments.

RESULTS: Morphometric variations were found along the small intestine with an increase in luminal area and a decrease in wall thickness from the duodenum to the ileum. The opening angle obtained after 60 min was highest in the duodenum (220.8±12.9°) and decreased along the length of the intestine to 143.9±8.9° in the jejunum and 151.4±9.4° in the ileum. The change of opening angle as a function of time, fitted well to the Kelvin model using the equation θ(t)/θo = [1-ηexp (-λt)] after the ring was cut. The computed creep rate λ did not differ between the segments. Compared to constant calculated from pig aorta and coronary artery, it showed that α agreed well (within 5%), η was three times larger than that for vascular tissue, and λ ranged ±40% from the value of the pig coronary artery and was a third of the value of pig aorta.

CONCLUSION: The change of opening angle over time for all the small intestine segments fits well to the standard linear spring-dashpot model. This viscoelastic constant of the rat small intestine is fairly homogenous along its length. The data obtained from this study add to a base set of biomechanical data on the small intestine and provide a reference state for comparison to other tissues, diseased intestinal tissue or intestinal tissue exposed to drugs or chemicals.

Keywords: Biomechanics, Standard linear solid, Creep, Opening angle