Table 3 Clinical outcomes pericardial effusion vs no pericardial effusion in left ventricular assist device
Pericardial effusion | No pericardial effusion | P value | |
Length of stay (days) | 40.52 ± 6.06 | 34.08 ± 1.39 | 0.043 |
Hospitalization cost (USD) | 847525 ± 93380 | 792616 ± 37959 | 0.035 |
Mortality | 9.38 ± 2.26 | 9.34% ± 0.40 | 1 |
- Citation: Khan MZ, Brailovsky Y, Bhuiyan MAN, Marhefka G, Faisal ASM, Sircar A, O'Neill P, Rame JE, Franklin S, Waqas M, Shah H, Rajapreyar I, Alvarez RJ. Incidence, risk factors and clinical outcomes of pericardial effusion in left ventricular assist device patients. World J Cardiol 2025; 17(6): 105330