Table 1 Studies revealing outcomes of pancreatic fluid collections with newly designed metal stents
| Study | n | Stent used | Size (cm) | Technical success, % | Clinical success, % | Necrosectomy, % |
| Walter et al[49], 2015 | 61 | AXIOS | 9.0 | 98.0 | PC-93 | 43.0 |
| PC-15 | WON-81 | |||||
| WON-46 | ||||||
| Shah et al[48], 2015 | 33 | AXIOS | 9 ± 3.3 | 91.0 | 93.0 | 33.0 |
| Chandran et al[46], 2015 | 47 | NAGI | 10.0 | 98.0 | 19.2 | |
| PC-38 | 76.6 | |||||
| WON-9 | ||||||
| Siddiqui et al[34], 2016 | 82 | AXIOS | 11.8 | 97.5 | PC-100 | All WON |
| PC-12 | WON-88 | |||||
| WON-68 | ||||||
| Sharaiha et al[54], 2016 | 124 | AXIOS | 9.5 | 100.0 | 86.3 | 62.9 |
| All WON | ||||||
| Rinninella et al[45], 2015 | 93 | Hot AXIOS | 10.0 | 98.9 | PC-100 | 59.6 |
| PC-18 | WON-90.4 | |||||
| WON-52 | ||||||
| Lakhtakia et al[65], 2016 | WON-205 | NAGI | 10.8 | 99.0 | 96.5 | 9.2 |
| Vazquez-Sequeiros et al[50], 2016 | 211 | FCMS-139 | 9.3 | 97.0 | 94.0 | 17.0 |
| PC-112 | AXIOS-72 | |||||
| WON-99 |