1
|
Dong Y, Wang WP, Ignee A, Zuo D, Qiu YJ, Zhang Q, Lu XY, Chen S, Dietrich CF. The diagnostic value of Doppler Resistive Index in the differential diagnosis of focal liver lesions. J Ultrason 2023; 23:e45-e52. [PMID: 37520747 PMCID: PMC10379844 DOI: 10.15557/jou.2023.0010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 01/03/2023] [Indexed: 08/01/2023] Open
Abstract
AIM To investigate the diagnostic value of resistance index (RI) in differentiating focal liver lesions. PATIENTS AND METHODS In this retrospective study, a total of 576 patients with histologically confirmed focal liver lesions were included. Each patient underwent B-mode ultrasound examination and color Doppler ultrasound examination. The RI values of different focal liver lesions were recorded and compared. RESULTS The mean RI value of benign lesions was significantly lower than that of malignant lesions (0.54 ± 0.10 vs. 0.71 ± 0.12) (p <0.05). In malignant lesions, the RI value of intrahepatic cholangiocarcinoma was significantly lower than that of hepatocellular carcinoma lesions. Furthermore, in hepatocellular carcinoma lesions, the RI of large lesions (group 4: >10 cm) was significantly lower than that of small lesions (group 1: ≤2 cm, group 2: 2-5 cm) (p <0.05). Taken RI of 0.615 as a cutoff value to differentiate malignant and benign lesions, the sensitivity, specificity, positive predictive value and negative predictive value were 82.80%, 81.00%, 81.34% and 82.48%, respectively. CONCLUSION Color Doppler ultrasound examination is a valuable imaging method in detecting blood flow signal within liver lesions. The RI parameter should be helpful in differentiating malignant and benign liver tumors.
Collapse
Affiliation(s)
- Yi Dong
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Wen-Ping Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Andre Ignee
- Department of Gastroenterology and Rheumatology, Julius-Spital Würzburg, Würzburg, Germany
| | - Dan Zuo
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yi-Jie Qiu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Qi Zhang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xiu-Yun Lu
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Sheng Chen
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Christoph Frank Dietrich
- Department General Internal Medicine, Hirslanden Clinics Beau-Site, Salem and Permancence, Bern, Switzerland
| |
Collapse
|
2
|
Cekuolis A, Schreiber-Dietrich D, Augustinienė R, Taut H, Squires J, Chaves EL, Dong Y, Dietrich CF. Incidental Findings in Pediatric Patients: How to Manage Liver Incidentaloma in Pediatric Patients. Cancers (Basel) 2023; 15:2360. [PMID: 37190288 PMCID: PMC10137002 DOI: 10.3390/cancers15082360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/11/2023] [Accepted: 04/12/2023] [Indexed: 05/17/2023] Open
Abstract
The World Federation for Ultrasound in Medicine and Biology (WFUMB) is addressing the issue of incidental findings (IFs) with a series of publications entitled "Incidental imaging findings-the role of ultrasound". IFs in the liver of newborns and children are rare and much less commonly encountered than in adults; as a result, they are relatively much more frequently malignant and life-threatening, even when they are of benign histology. Conventional B-mode ultrasound is the well-established first line imaging modality for the assessment of liver pathology in pediatric patients. US technological advances, resulting in image quality improvement, contrast-enhanced ultrasound (CEUS), liver elastography and quantification tools for steatosis have expanded the use of ultrasound technology in daily practice. The following overview is intended to illustrate incidentally detected liver pathology covering all pediatric ages. It aims to aid the examiner in establishing the final diagnosis. Management of incidentally detected focal liver lesions (FLL) needs to take into account the diagnostic accuracy of each imaging modality, the patient's safety issues (including ionizing radiation and nephrotoxic contrast agents), the delay in diagnosis, the psychological burden on the patient and the cost for the healthcare system. Moreover, this paper should help the pediatric clinician and ultrasound practitioner to decide which pathologies need no further investigation, which ones require interval imaging and which cases require further and immediate diagnostic procedures.
Collapse
Affiliation(s)
- Andrius Cekuolis
- Ultrasound Section, Department of Pediatric Radiology, Radiology and Nuclear Medicine Centre, Vilnius University Hospital Santaros Klinikos, 08661 Vilnius, Lithuania
| | | | - Rasa Augustinienė
- Ultrasound Section, Department of Pediatric Radiology, Radiology and Nuclear Medicine Centre, Vilnius University Hospital Santaros Klinikos, 08661 Vilnius, Lithuania
| | - Heike Taut
- Children’s Hospital, Universitätsklinikum Dresden, Technische Universität Dresden, 01062 Dresden, Germany
| | - Judy Squires
- Department of Radiology, UPMC Children’s Hospital of Pittsburgh, Pittsburgh, PA 15224, USA
| | - Edda L. Chaves
- Radiology Department, Hospital Regional Nicolas Solano, La Chorrera 1007, Panama
| | - Yi Dong
- Department of Ultrasound, Xinhua Hospital affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China
| | - Christoph F. Dietrich
- Department Allgemeine Innere Medizin (DAIM), Kliniken Hirslanden Beau Site, Salem und Permancence, 3013 Bern, Switzerland
| |
Collapse
|
3
|
Chang KP, Lin SH, Chu YW. Artificial intelligence in gastrointestinal radiology: A review with special focus on recent development of magnetic resonance and computed tomography. Artif Intell Gastroenterol 2021; 2:27-41. [DOI: 10.35712/aig.v2.i2.27] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 03/21/2021] [Accepted: 04/20/2021] [Indexed: 02/06/2023] Open
|
4
|
Sui P, Wang X, Sun L, Wang H. Diagnostic accuracy of ultrasound superb microvascular imaging for focal liver lesions: A protocol for systematic review and meta-analysis. Medicine (Baltimore) 2021; 100:e24411. [PMID: 33546085 PMCID: PMC7837924 DOI: 10.1097/md.0000000000024411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Accepted: 01/04/2021] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Superb microvascular imaging (SMI) is a new ultrasound vascular imaging technology, which uses a new Doppler algorithm, it has the characteristics of high sensitivity and high resolution to detect low velocity blood flow; it is easier to detect microvessels with low-velocity flow compared with color Doppler flow imaging in theory; and it can image the microvessels of the lesion without angiography.[1] Previous studies showed that SMI can detect tumor neovascularization to differentiate benign from malignant focal liver lessions (FLLs). However, the results of these studies have been contradictory with low sample sizes. This meta-analysis tested the hypothesis that SMI is accurate in distinguishing benign and malignant FLLs. METHODS We will search PubMed, Web of Science, Cochrane Library, and Chinese biomedical databases from their inceptions to the November 30, 2020, without language restrictions. Two authors will independently carry out searching literature records, scanning titles and abstracts, full texts, collecting data, and assessing risk of bias. Review Manager 5.2 and Stata14.0 software will be used for data analysis. RESULTS This systematic review will determine the accuracy of SMI in the differential diagnosis between benign and malignant FLLs. CONCLUSION Its findings will provide helpful evidence for the accuracy of SMI in the differential diagnosis between benign and malignant FLLs. SYSTEMATIC REVIEW REGISTRATION INPLASY2020120081.
Collapse
|
5
|
Dong Y, Teufel A, Wang WP, Dietrich CF. Current Opinion about Hepatocellular Carcinoma <10 mm. Digestion 2020; 102:335-341. [PMID: 32516767 DOI: 10.1159/000507923] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Accepted: 04/14/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND Early detection of hepatocellular carcinoma (HCC) is important. Advances in liver imaging techniques have facilitated the detection of HCC at an early stage. However, there is a controversial discussion on how to diagnose very small HCC by imaging. The aim of the current review is to present current published data on HCC ≤10 mm and discuss on how to best diagnose and treat such lesions. SUMMARY It is still challenging, however, to accurately characterize HCC <10 mm. The accuracy of contrast-enhanced ultrasound may be critical for early treatment decisions for cancer patients, particularly when CECT and/or CEMRI are inconclusive. Key Messages: The characterization of focal liver lesions <10 mm is frequently delayed until a follow-up imaging procedure demonstrates growth or stability. A repetition of ultrasound examination after 3 months for new nodules <1 cm should be recommended.
Collapse
Affiliation(s)
- Yi Dong
- Ultrasound Department, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Andreas Teufel
- Division of Hepatology, Department of Medicine II, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Wen-Ping Wang
- Ultrasound Department, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Christoph F Dietrich
- Department Allgemeine Innere Medizin (DAIM), Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland,
| |
Collapse
|
6
|
Guo Y, Qin X, Chen S, Liu X, Gu P. Diagnosis efficacy of CEUS for hepatic inflammatory lesions. J Clin Lab Anal 2020; 34:e23231. [PMID: 32017229 PMCID: PMC7307339 DOI: 10.1002/jcla.23231] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 01/09/2020] [Accepted: 01/09/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose In this study, the efficacy of US/CEUS and clinicopathologic parameters in differential diagnosis of hepatic inflammatory lesions were evaluated. Methods This was a retrospective study in which CEUS imaging was performed on 182 patients. Among these patients, 44 patients had hepatic inflammatory lesions and 138 patients had malignant lesions. The ultrasound (US), CEUS, and clinicopathologic parameters with respect to differential diagnosis of hepatic inflammatory lesions were analyzed. Results Irregular lesion shape and unclear margin were commonly seen in hepatic inflammatory lesions by US/CEUS examination. Hypoenhancement in arterial phase (AP) and portal venous phase (PVP), and isoenhancement in delayed phase (DP) were more commonly found in inflammatory lesions rather than malignant lesions [9% (4/44), 68% (30/44), and 16% (7/44) vs 2% (3/138), 11% (15/138), 1% (1/138), respectively; P < .05]. The enhancement coverage was also a significant indicator for the differentiation of inflammatory lesions and malignant lesions (P < .05). History of hepatitis or cirrhosis, and higher serum alpha‐fetoprotein (AFP) level were indicators for malignant lesions, while liver parasites and higher body temperature were indicators for inflammatory lesions. When the US/CEUS findings were combined with clinicopathologic parameters, the diagnostic accuracy of inflammatory lesions could reach 93.3%, with sensitivity, specificity, positive predictive value, and negative predictive value of 63.64%, 96.03%, 84.85%, and 88.32%, respectively. Conclusion The US/CEUS findings combined with clinical characteristics can accurately differentiate hepatic inflammatory lesions and malignant lesions. The results of study will improve the diagnostic confidence for hepatic inflammatory lesions.
Collapse
Affiliation(s)
- Yuanyuan Guo
- Department of Gynaecology and ObstetricsAffiliated Hospital of North Sichuan Medical CollegeNanchongChina
| | - Xiachuan Qin
- Department of UltrasoundNanchong Central HospitalSichuanChina
| | - Shaoxian Chen
- Radiology DepartmentGaoping District People Hospital of NanchongNanchongChina
| | - Xuebin Liu
- Department of UltrasoundNanchong Central HospitalSichuanChina
| | - Peng Gu
- Department of UltrasoundAffiliated Hospital of North Sichuan Medical CollegeNanchongChina
| |
Collapse
|
7
|
Dietrich CF, Potthoff A, Helmberger T, Ignee A, Willmann JK. [Contrast-enhanced ultrasound: Liver Imaging Reporting and Data System (CEUS LI-RADS)]. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2018; 56:499-506. [PMID: 29734449 DOI: 10.1055/s-0043-124874] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The American College of Radiology (ACR) endorsed the Liver Imaging Reporting and Data System (LI-RADS) for standardized reporting and data collection of computed tomography (CT) and magnetic resonance (MR) imaging for hepatocellular carcinoma (HCC) in high-risk patients (liver cirrhosis). The LI-RADS imaging criteria are used to classify 'observations' from 'definitely benign' (LR-1) to 'definitely HCC' (LR-5) based on imaging criteria.Coincidently, the recent approval in the United States of a microbubble contrast agent for liver imaging (Lumason®, known as SonoVue® in Europe and elsewhere), LI-RADS. is being expanded to include contrast-enhanced ultrasound (CEUS). An international working group was initiated in 2014. Herewith, the most current version of CEUS-LI-RADS is presented.
Collapse
Affiliation(s)
| | - Andrej Potthoff
- Department of Gastroenterology, Hepatology and Endocrinology, Medizinische Hochschule Hannover, Hannover, Germany
| | - Thomas Helmberger
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Klinikum Bogenhausen, Munich, Germany
| | - Andre Ignee
- Department of Internal Medicine 2, Caritas-Krankenhaus Bad Mergentheim, Germany
| | | |
Collapse
|
8
|
He MN, Lv K, Jiang YX, Jiang TA. Application of superb microvascular imaging in focal liver lesions. World J Gastroenterol 2017; 23:7765-7775. [PMID: 29209117 PMCID: PMC5703936 DOI: 10.3748/wjg.v23.i43.7765] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 09/14/2017] [Accepted: 09/19/2017] [Indexed: 02/06/2023] Open
Abstract
AIM To explore the ability of superb microvascular imaging (SMI) in differential diagnosis of focal liver lesions (FLLs) and to compare SMI morphology findings to those of color Doppler ultrasound and enhanced imaging.
METHODS Twenty-four patients with 31 FLLs were included in our study, with diagnoses of hemangioma (HE) (n = 17), hepatocellular carcinoma (HCC) (n = 5), metastatic lesions (n = 5), primary hepatic lymphoma (n = 1), focal nodular hyperplasia (FNH) (n = 2), and adenoma (n = 1). Nine lesions were pathologically diagnosed, and 22 lesions were radiologically confirmed, all of which were evaluated by at least two types of enhanced imaging techniques. All patients had undergone SMI. Patients were divided into subgroups based on pathological and radiological diagnoses to analyze SMI manifestations. We also compared the SMI manifestations of the most common malignant FLLs (HCCs and metastatic lesions) with those of the most common benign FLLs (HEs).
RESULTS HEs were classified into three SMI subgroups: diffuse dot-like type (n = 6), strip rim type (n = 8), and nodular rim type (n = 3). The sizes of the three types of HEs were significantly different (P = 0.00, < 0.05). HCCs were classified into two subgroups: diffuse honeycomb type (n = 2) and non-specific type (n = 3). Four of the metastatic lesions were the strip rim type, and the other metastatic lesion was the thick rim type, which is the same as that of lymphoma. FNH was described as a spoke-wheel type, and adenoma as a diffuse honeycomb type. The SMI types of HCCs and metastatic lesions were significantly different from those of HEs (P = 0.048, < 0.05).
CONCLUSION SMI technology enables microvascular evaluation of FLLs without using any contrast agent. For HEs, lesion size may affect SMI performance. SMI is able to provide useful information for differential diagnosis of HCCs and metastatic lesions from HEs.
Collapse
Affiliation(s)
- Meng-Na He
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Ke Lv
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Yu-Xin Jiang
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Tian-An Jiang
- Department of Ultrasound, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310000, Zhejiang Province, China
| |
Collapse
|
9
|
Mogensen MB, Hansen ML, Henriksen BM, Axelsen T, Vainer B, Osterlind K, Nielsen MB. Dynamic Contrast-Enhanced Ultrasound of Colorectal Liver Metastases as an Imaging Modality for Early Response Prediction to Chemotherapy. Diagnostics (Basel) 2017; 7:diagnostics7020035. [PMID: 28604623 PMCID: PMC5489955 DOI: 10.3390/diagnostics7020035] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2017] [Revised: 05/21/2017] [Accepted: 06/06/2017] [Indexed: 12/12/2022] Open
Abstract
Our aim was to investigate whether dynamic contrast-enhanced ultrasound (DCE-US) can detect early changes in perfusion of colorectal liver metastases after initiation of chemotherapy. Newly diagnosed patients with colorectal cancer with liver metastases were enrolled in this explorative prospective study. Patients were treated with capecitabine or 5-fluorouracil-based chemotherapy with or without bevacizumab. DCE-US was performed before therapy (baseline) and again 10 days after initiation of treatment. Change in contrast-enhancement in one liver metastasis (indicator lesion) was measured. Treatment response was evaluated with a computed tomography (CT) scan after three cycles of treatment and the initially observed DCE-US change of the indicator lesion was related to the observed CT response. Eighteen patients were included. Six did not complete three series of chemotherapy and the evaluation CT scan, leaving twelve patients for analysis. Early changes in perfusion parameters using DCE-US did not correlate well with subsequent CT changes. A subgroup analysis of eight patients receiving bevacizumab, however, demonstrated a statistically significant correlation (p = 0.045) between early changes in perfusion measures of peak enhancement at DCE-US and tumor shrinkage at CT scan. The study indicates that early changes in DCE-US perfusion measures may predict subsequent treatment response of colorectal liver metastases in patients receiving bevacizumab.
Collapse
Affiliation(s)
- Marie Benzon Mogensen
- Department of Oncology, Copenhagen University, Rigshospitalet, Copenhagen 2100, Denmark.
| | | | | | - Thomas Axelsen
- Department of Radiology, Copenhagen University, Rigshospitalet, Copenhagen 2100, Denmark.
| | - Ben Vainer
- Department of Pathology, Copenhagen University, Rigshospitalet, Copenhagen 2100, Denmark.
| | - Kell Osterlind
- Department of Oncology, Copenhagen University, Rigshospitalet, Copenhagen 2100, Denmark.
| | | |
Collapse
|
10
|
Dong Y, Mao F, Cao J, Fan P, Wang WP. Characterization of Focal Liver Lesions Indistinctive on B Mode Ultrasound: Benefits of Contrast-Enhanced Ultrasound. BIOMED RESEARCH INTERNATIONAL 2017; 2017:8970156. [PMID: 28497069 PMCID: PMC5405373 DOI: 10.1155/2017/8970156] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 03/30/2017] [Indexed: 12/12/2022]
Abstract
Aim. The aim of this prospective study was to evaluate the additional value of contrast-enhanced ultrasound (CEUS) in identifying and characterizing of focal liver lesions (FLLs) that are indistinctive on B mode ultrasound (BMUS). Methods. The study focused on 70 consecutive patients (male 46, female 24; mean age, 53.1 years ± 10). All lesions were detected by MRI but could not be clearly visualized by BMUS. CEUS was performed by injected SonoVue® (Bracco Imaging Spa, Milan, Italy) as a quick bolus into the antecubital vein. All lesions were proved by pathologic and MRI findings as primary or metastatic hepatic malignancies. Results. On CEUS, 45 (64.2%) FLLs displayed arterial hyperenhancement and 55 (78.5%) lesions showed hypoenhancement in portal venous and late phase (PVLP). Homogeneous and complete hyperenhancement pattern during the arterial phase is highly suspicious for HCC in liver cirrhosis (96.8%). Arterial isoenhancement and early washout during PVLP are characteristic for metastasis (73.3%). For recurrence lesions, arterial hyperenhancement and isoenhancement during PVLP are more common (60%). Conclusion. CEUS may provide added diagnostic values in FLLs appearing indistinctive on BMUS. Presence of early arterial enhancement and washout during PVLP may be helpful for detection of those lesions.
Collapse
Affiliation(s)
- Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Feng Mao
- Shanghai Institute of Imaging, 180 Fenglin Road, Shanghai 200032, China
| | - Jiaying Cao
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Peili Fan
- Shanghai Institute of Imaging, 180 Fenglin Road, Shanghai 200032, China
| | - Wen-Ping Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| |
Collapse
|
11
|
Dietrich CF, Dong Y, Froehlich E, Hocke M. Dynamic contrast-enhanced endoscopic ultrasound: A quantification method. Endosc Ultrasound 2017; 6:12-20. [PMID: 28218195 PMCID: PMC5331837 DOI: 10.4103/2303-9027.193595] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 06/05/2016] [Indexed: 12/12/2022] Open
Abstract
Dynamic contrast-enhanced ultrasound (DCE-US) has been recently standardized by guidelines and recommendations. The European Federation of Societies for US in Medicine and Biology position paper describes the use for DCE-US. Comparatively, little is known about the use of contrast-enhanced endoscopic US (CE-EUS). This current paper reviews and discusses the clinical use of CE-EUS and DCE-US. The most important clinical use of DCE-US is the prediction of tumor response to new drugs against vascular angioneogenesis.
Collapse
Affiliation(s)
- Christoph F. Dietrich
- Department of Internal Medicine 2, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Germany
| | - Yi Dong
- Department of Internal Medicine 2, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Germany
| | | | - Michael Hocke
- Department of Internal Medicine 2, Helios Hospital Meiningen GmbH, Academic Teaching Hospital of the University of Jena, Germany
| |
Collapse
|
12
|
Dong Y, Zhang XL, Mao F, Huang BJ, Si Q, Wang WP. Contrast-enhanced ultrasound features of histologically proven small (≤20 mm) liver metastases. Scand J Gastroenterol 2017; 52:23-28. [PMID: 27577113 DOI: 10.1080/00365521.2016.1224380] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Revised: 07/31/2016] [Accepted: 08/04/2016] [Indexed: 02/04/2023]
Abstract
OBJECTIVE We analyzed contrast-enhanced ultrasound (CEUS) features of histologically proved small (≤20 mm) liver metastases, in comparison to small (≤20 mm) hepatocellular carcinomas (HCC), to define the differentiate diagnoses value of CEUS in clinical practice. MATERIAL AND METHODS Eighty-two cases of small (≤20 mm) liver metastases and 84 cases of small (≤20 mm) HCC were retrospectively reviewed. All patients had CEUS images. Two radiologists assessed CEUS enhancement pattern and time of enhancement in consensus. Statistical analyses were performed using SPSS v.19.0 (SPSS Inc., Chicago, IL). The χ2 test and the independent sample t-test were used to compare the differences. RESULTS Comparing to small HCCs, rapid rim-like hyper-enhancement in arterial phase (56.1% in liver metastases vs. 2.3% in HCCs, p < .01), rapid wash-out and become hypo-enhancement in late arterial phase or early portal venous phase (96.4% in liver metastases vs. 22.6% in HCCs, p < .01) with central non-enhanced area in late phase were characteristic CEUS features of small metastases. CONCLUSIONS CEUS imaging enhancement findings reliably offer typical signs of small liver metastases, differentiate effectively with small HCCs. CEUS can help to improve the diagnostic confidence of small liver metastases.
Collapse
Affiliation(s)
- Yi Dong
- a Department of Ultrasound , Zhongshan Hospital, Fudan University , Shanghai , China
| | - Xiao-Long Zhang
- b Department of Ultrasound , Shanghai Institute of Imaging , Shanghai , China
| | - Feng Mao
- b Department of Ultrasound , Shanghai Institute of Imaging , Shanghai , China
| | - Bei-Jian Huang
- a Department of Ultrasound , Zhongshan Hospital, Fudan University , Shanghai , China
| | - Qin Si
- c Department of Ultrasound , 81st Hospital of Chinese PLA , Nanjing Jiangsu , China
| | - Wen-Ping Wang
- a Department of Ultrasound , Zhongshan Hospital, Fudan University , Shanghai , China
| |
Collapse
|
13
|
Ignee A, Atkinson NSS, Schuessler G, Dietrich CF. Ultrasound contrast agents. Endosc Ultrasound 2016; 5:355-362. [PMID: 27824024 PMCID: PMC5206822 DOI: 10.4103/2303-9027.193594] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Accepted: 05/15/2016] [Indexed: 02/07/2023] Open
Abstract
Endoscopic ultrasound (EUS) plays an important role in imaging of the mediastinum and abdominal organs. Since the introduction of US contrast agents (UCA) for transabdominal US, attempts have been made to apply contrast-enhanced US techniques also to EUS. Since 2003, specific contrast-enhanced imaging was possible using EUS. Important studies have been published regarding contrast-enhanced EUS and the characterization of focal pancreatic lesions, lymph nodes, and subepithelial tumors. In this manuscript, we describe the relevant UCA, their application, and specific image acquisition as well as the principles of image tissue characterization using contrast-enhanced EUS. Safety issues, potential future developments, and EUS-specific issues are reviewed.
Collapse
Affiliation(s)
- Andre Ignee
- Department of Medical, Caritas-Krankenhaus, Bad Mergentheim, Germany
| | | | - Gudrun Schuessler
- Department of Medical, Caritas-Krankenhaus, Bad Mergentheim, Germany
| | | |
Collapse
|
14
|
Dong Y, Zhu Z, Wang WP, Mao F, Ji ZB. Ultrasound features of hepatocellular adenoma and the additional value of contrast-enhanced ultrasound. Hepatobiliary Pancreat Dis Int 2016; 15:48-54. [PMID: 26818543 DOI: 10.1016/s1499-3872(15)60039-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Hepatocellular adenoma (HCA) is a rare benign tumor of the liver. It is of clinical importance to differentiate HCA from other liver tumors, especially hepatocellular carcinoma (HCC). This study aimed to evaluate the characteristic features of HCA by conventional ultrasound and contrast-enhanced ultrasound (CEUS) findings. METHODS Twenty-six patients (10 males and 16 females; mean age 36.2+/-5.0 years) with 26 histopathologically proven HCAs were retrospectively identified. According to the maximum diameter of HCAs, they were divided into three groups: <30 mm, 30-50 mm, and >50 mm. Ultrasound examinations were performed with C5-2 broadband curved transducer of Philips iU22 unit (Philips Bothell, WA, USA). For each lesion, a dose of 2.4 mL SonoVue® (Bracco Imaging Spa, Milan, Italy) was injected as a quick bolus into the cubital vein. Lesions' echogenicity, color-Doppler flow imaging and contrast enhancement patterns were recorded. RESULTS Grayscale ultrasound revealed that most of HCAs were hypoechoic (73.1%, 19/26). Spotty calcifications were detected in 26.9% (7/26) of the lesions. Color-Doppler flow imaging detected centripetal bulky color flow in 46.2% (12/26) of the HCAs. CEUS showed that 73.1% (19/26) of the HCAs displayed as rapid, complete and homogenous enhancement, and 53.8% (14/26) showed decreased contrast enhancement in the late phase. There was no significant difference in enhancement patterns among different sizes of HCAs (P>0.05). Centripetal enhancement with subcapsular tortuous arteries was common in larger HCAs. CONCLUSIONS CEUS combined with grayscale and color-Doppler flow imaging helped to improve preoperative diagnosis of HCAs. The characteristic imaging features of HCAs included: rapid homogeneous enhancement and slow wash-out pattern on CEUS; heterogeneous echogenicity on grayscale ultrasound; and centripetal enhancement with subcapsular tortuous arteries in large HCAs.
Collapse
Affiliation(s)
- Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
| | | | | | | | | |
Collapse
|
15
|
Chiorean L, Cui XW, Tannapfel A, Franke D, Stenzel M, Kosiak W, Schreiber-Dietrich D, Jüngert J, Chang JM, Dietrich CF. Benign liver tumors in pediatric patients - Review with emphasis on imaging features. World J Gastroenterol 2015; 21:8541-8561. [PMID: 26229397 PMCID: PMC4515836 DOI: 10.3748/wjg.v21.i28.8541] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2015] [Revised: 04/16/2015] [Accepted: 05/20/2015] [Indexed: 02/07/2023] Open
Abstract
Benign hepatic tumors are commonly observed in adults, but rarely reported in children. The reasons for this remain speculative and the exact data concerning the incidence of these lesions are lacking. Benign hepatic tumors represent a diverse group of epithelial and mesenchymal tumors. In pediatric patients, most benign focal liver lesions are inborn and may grow like the rest of the body. Knowledge of pediatric liver diseases and their imaging appearances is essential in order to make an appropriate differential diagnosis. Selection of the appropriate imaging test is challenging, since it depends on a number of age-related factors. This paper will discuss the most frequently encountered benign liver tumors in children (infantile hepatic hemangioendothelioma, mesenchymal hamartoma, focal nodular hyperplasia, nodular regenerative hyperplasia, and hepatocellular adenoma), as well as a comparison to the current knowledge regarding such tumors in adult patients. The current emphasis is on imaging features, which are helpful not only for the initial diagnosis, but also for pre- and post-treatment evaluation and follow-up. In addition, future perspectives of contrast-enhanced ultrasound (CEUS) in pediatric patients are highlighted, with descriptions of enhancement patterns for each lesion being discussed. The role of advanced imaging tests such as CEUS and magnetic resonance imaging, which allow for non-invasive assessment of liver tumors, is of utmost importance in pediatric patients, especially when repeated imaging tests are needed and radiation exposure should be avoided.
Collapse
|
16
|
Jung EM, Platz Batista da Silva N, Jung W, Farkas S, Stroszczynski C, Rennert J. Is Strain Elastography (IO-SE) Sufficient for Characterization of Liver Lesions before Surgical Resection--Or Is Contrast Enhanced Ultrasound (CEUS) Necessary? PLoS One 2015; 10:e0123737. [PMID: 26114286 PMCID: PMC4482620 DOI: 10.1371/journal.pone.0123737] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Accepted: 12/19/2014] [Indexed: 12/21/2022] Open
Abstract
Aim To evaluate the diagnostic accuracy of IO-SE in comparison to IO-CEUS for the differentiation between malignant and benign liver lesions. Material and Methods In a retrospective diagnostic study IO-CEUS and SE examinations of 49 liver lesions were evaluated and compared to histopathological examinations. Ultrasound was performed using a multifrequency linear probe (6–9 MHz). The loops of CEUS were evaluated up to 5 min. The qualitative characterization of IO-SE was based on a color coding system (blue = hard, red = soft). Stiffness of all lesions was quantified by a specific scaling of 0–6 (0 = low, 6 = high) using 7 ROIs (2 central, 5 peripheral). Results All malignant lesions displayed a characteristic portal venous washout and could be diagnosed correctly by IO-CEUS. 3/5 benign lesions could not be characterized properly either by IO-CEUS or IO-SE prior to resection. Thus for IO-CEUS sensitivity, specificity, positive and negative predictive value and accuracy were 100%, 40%, 94%, 100% and 94%. Lesion sizes were between 8 and 59 mm in diameter. Regarding the IO-SE, malignant lesions showed a marked variability. In qualitative analysis, 31 of the malignant lesions were blue colored denoting overall induration. Thirteen malignant lesions showed an inhomogenous color pattern with partial indurations. Two of the benign lesions also displayed overall induration. The other benign lesions showed an inhomogenous color mapping. Calculated sensitivity of the SE was 70.5%, specificity 60%, PPV 94%, NPV 18.75%, and accuracy 69%. Conclusion IO-CEUS is useful for localization and characterization of liver lesions prior to surgical resection whereas IO-SE provided correct characterization only for a limited number of lesions.
Collapse
Affiliation(s)
- Ernst Michael Jung
- University Hospital Regensburg, Department of Radiology, Regensburg, Germany
| | | | - Wolfgang Jung
- Saarland University, Department of Materials Research, Saarbrücken, Germany
| | - Stefan Farkas
- University Hospital Regensburg, Department of Surgery, Regensburg, Germany
| | | | - Janine Rennert
- University Hospital Regensburg, Department of Radiology, Regensburg, Germany
| |
Collapse
|
17
|
Continuous dynamic registration of microvascularization of liver tumors with contrast-enhanced ultrasound. Radiol Res Pract 2014; 2014:347416. [PMID: 24991432 PMCID: PMC4060158 DOI: 10.1155/2014/347416] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Revised: 04/09/2014] [Accepted: 04/23/2014] [Indexed: 12/16/2022] Open
Abstract
Aim. To evaluate the diagnostic value of quantification of liver tumor microvascularization using contrast-enhanced ultrasound (CEUS) measured continuously from the arterial phase to the late phase (3 minutes). Material and Methods. We present a retrospective analysis of 20 patients with malignant (n = 13) or benign (n = 7) liver tumors. The tumors had histopathologically been proven or clearly identified using contrast-enhanced reference imaging with either 1.5 T MRI (liver specific contrast medium) or triphase CT and follow-up. CEUS was performed using a multifrequency transducer (1–5 MHz) and a bolus injection of 2.4 mL sulphur hexafluoride microbubbles. A retrospective perfusion analysis was performed to determine TTP (time-to-peak), RBV (regional blood volume), RBF (regional blood flow), and Peak. Results. Statistics revealed a significant difference (P < 0.05) between benign and malignant tumors in the RBV, RBF, and Peak but not in TTP (P = 0.07). Receiver operating curves (ROC) were generated for RBV, RBF, Peak, and TTP with estimated ROC areas of 0.97, 0.96, 0.98, and 0.76, respectively. Conclusion. RBV, RBF, and Peak continuously measured over a determined time period of 3 minutes could be of valuable support in differentiating malignant from benign liver tumors.
Collapse
|
18
|
Dietrich C, Schreiber-Dietrich D, Nürnberg D. Abdominelle Sonographie. DER GASTROENTEROLOGE 2013; 8:341-356. [DOI: 10.1007/s11377-013-0766-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2023]
|
19
|
Dietrich CF, Sharma M, Gibson RN, Schreiber-Dietrich D, Jenssen C. Fortuitously discovered liver lesions. World J Gastroenterol 2013; 19:3173-3188. [PMID: 23745019 PMCID: PMC3671069 DOI: 10.3748/wjg.v19.i21.3173] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2012] [Revised: 03/22/2013] [Accepted: 04/27/2013] [Indexed: 02/06/2023] Open
Abstract
The fortuitously discovered liver lesion is a common problem. Consensus might be expected in terms of its work-up, and yet there is none. This stems in part from the fact that there is no preventive campaign involving the early detection of liver tumors other than for patients with known liver cirrhosis and oncological patients. The work-up (detection and differential diagnosis) of liver tumors comprises theoretical considerations, history, physical examination, laboratory tests, standard ultrasound, Doppler ultrasound techniques, contrast-enhanced ultrasound (CEUS), computed tomography and magnetic resonance imaging, as well as image-guided biopsy. CEUS techniques have proved to be the most pertinent method; these techniques became part of the clinical routine about 10 years ago in Europe and Asia and are used for a variety of indications in daily clinical practice. CEUS is in many cases the first and also decisive technical intervention for detecting and characterizing liver tumors. This development is reflected in many CEUS guidelines, e.g., in the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines 2004, 2008 and 2012 as well as the recently published World Federation for Ultrasound in Medicine and Biology-EFSUMB guidelines 2012. This article sets out considerations for making a structured work-up of incidental liver tumors feasible.
Collapse
|
20
|
Wang W, Chen LD, Lu MD, Liu GJ, Shen SL, Xu ZF, Xie XY, Wang Y, Zhou LY. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT. Eur Radiol 2013; 23:2546-54. [PMID: 23624595 DOI: 10.1007/s00330-013-2849-3] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2013] [Revised: 02/18/2013] [Accepted: 03/01/2013] [Indexed: 02/08/2023]
Abstract
OBJECTIVES To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). METHODS CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. RESULTS Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs ≤3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs ≥3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CONCLUSION CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. KEY POINTS • The confident diagnosis of focal nodular hyperplasia is important in liver imaging. • The centrifugal filling sign is useful for diagnosis of FNHs ≤3 cm. • Contrast-enhanced ultrasound and contrast-enhanced CT have similar diagnostic performance for FNH. • CEUS should be the first-line imaging technique for the diagnosis of FNH.
Collapse
Affiliation(s)
- Wei Wang
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-Sen University Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, NO.58 Zhongshan Road 2, Guangzhou, 510080, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|