BPG is committed to discovery and dissemination of knowledge
Observational Study
Copyright: ©Author(s) 2026.
World J Crit Care Med. Sep 9, 2026; 15(3): 119057
Published online Sep 9, 2026. doi: 10.5492/wjccm.119057
Table 1 Ventilatory parameters, mechanical power, and lung ultrasound score over time, mean ± SD
Parameter (unit)
0 hours
24 hours
48 hours
72 hours
FiO2 (%)85.23 ± 16.5678.18 ± 20.2976.93 ± 21.8973.63 ± 26.46
Tidal volume (mL)355.34 ± 37.10354.00 ± 31.80350.68 ± 28.89354.43 ± 34.05
Respiratory rate (per minute)25.34 ± 4.3026.05 ± 3.6926.43 ± 4.6626.91 ± 6.54
Minute ventilation (L/minute)9.11 ± 1.949.22 ± 1.399.37 ± 1.539.99 ± 4.30
PEEP (cm H2O)10.27 ± 2.3011.08 ± 2.5611.38 ± 3.4411.89 ± 4.50
Peak inspiratory pressure (cm H2O)30.09 ± 6.0029.64 ± 6.9030.05 ± 8.6429.43 ± 10.86
Plateau pressure (cm H2O)26.77 ± 6.1926.34 ± 6.7226.68 ± 8.1626.39 ± 10.49
Respiratory system compliance (mL/cm H2O)23.93 ± 8.0826.53 ± 9.4726.45 ± 10.4128.93 ± 13.97
Driving pressure (cm H2O)16.63 ± 5.8315.15 ± 5.0615.28 ± 5.7215.13 ± 6.67
Mechanical power (J/minute)19.20 ± 4.8419.99 ± 6.0720.70 ± 7.9221.76 ± 10.95
Lung ultrasound score18.18 ± 4.4019.18 ± 5.9120.00 ± 7.9120.43 ± 9.57