1
|
Dondapati A, Carroll TJ, Hammert WC, Gonzalez R, Ketonis C. Clinical and Radiographic Outcomes of Distal Radius Fractures Following Dorsal Bridge Fixation to the Second Versus Third Metacarpal. J Hand Surg Am 2025:S0363-5023(24)00642-7. [PMID: 39891623 DOI: 10.1016/j.jhsa.2024.12.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 11/12/2024] [Accepted: 12/18/2024] [Indexed: 02/03/2025]
Abstract
PURPOSE Dorsal bridge plating (DBP) can effectively treat complex distal radius fractures (DRFs); however, techniques for metacarpal fixation vary. The purpose of our study was to compare range of motion (ROM), grip strength, patient-reported outcomes, radiographic parameters, and complication rates between patients undergoing DBP with fixation to the second versus third metacarpal for DRFs. METHODS We retrospectively analyzed 432 patients with DRFs. Wrist ROM and radiographic data were calculated at the 6-month follow-up. We calculated Patient-Reported Outcomes Measurement Information System (PROMIS) upper-extremity, physical function, and pain interference at each visit. Additional data collected included surgical complications and demographic data. Statistical analysis was conducted via multivariate analysis, t tests, and chi-square tests. RESULTS A total of 329 patients underwent DBP to the second metacarpal, whereas 103 patients underwent DBP to the third. Demographics and comorbidities were similar between the groups. Tendon rupture was more common in the third metacarpal group (3.9% vs 0.9%), with two extensor pollicis longus and one extensor indicis proprius ruptures in each group and an unspecified tendon in the third metacarpal cohort. All other complication rates were similar. The second metacarpal group demonstrated greater wrist flexion (57.8° vs 56.2°), ulnar deviation (23.9° vs 20.7°), and grip strength (62.3% vs 57.8%). All other ROM measurements were similar. There was no difference in PROMIS metrics at the 6-month follow-up. The second metacarpal group demonstrated greater radial inclination (21.3° vs 19.5°) and less volar tilt (6.8° vs 7.1°). CONCLUSIONS Dorsal bridge plating to the second metacarpal demonstrated greater ROM, grip strength, and radial inclination, similar PROMIS scores, and lower extensor tendon rupture rates than third metacarpal fixation. Although there were differences between techniques, their clinical relevance is unclear. Dorsal bridge plating to the second or third metacarpal both result in acceptable outcomes and can be considered based on the fracture pattern and surgeon preference. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.
Collapse
Affiliation(s)
- Akhil Dondapati
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, NY.
| | - Thomas J Carroll
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, NY
| | - Warren C Hammert
- Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, NC
| | - Ronald Gonzalez
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, NY
| | - Constantinos Ketonis
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, NY
| |
Collapse
|
2
|
Modest JM, Raducha JE, Schilkowsky RM, Molino J, Got CJ, Katarincic JA, Gil JA. Supplementary Fixation Improves Stability of Intra-Articular Distal Radius Fractures Managed With a Spanning Plate. J Hand Surg Am 2024; 49:1039.e1-1039.e9. [PMID: 36792395 DOI: 10.1016/j.jhsa.2023.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 12/11/2022] [Accepted: 01/04/2023] [Indexed: 02/17/2023]
Abstract
PURPOSE Previous studies evaluating weight bearing of distal radius fractures treated through dorsal spanning bridge plates used extra-articular fracture models, and have not evaluated the role of supplementary fixation. We hypothesized that supplementary fixation with a spanning dorsal bridge plate for an intra-articular wrist fracture would decrease the displacement of individual articular pieces with cyclic axial loading and allow for walker or crutch weight bearing. METHODS Thirty cadaveric forearms were matched into 3 cohorts, controlling for age, sex, and bone mineral density. An intra-articular fracture model was fixed with the following 3 techniques: (1) cohort A with a dorsal bridge plate, (2) cohort B with a dorsal bridge plate and two 1.6-mm k-wires, and (3) cohort C with a dorsal bridge plate and a radial pin plate. Specimens were axially loaded cyclically with escalating weights consistent with walker and crutch weight-bearing with failure defined as 2-mm displacement. RESULTS No specimens failed at 2- or 5-kg weights, but cohort A had significantly more displacement at these weights compared with cohort B. Cohort A had significantly more failure than cohort C. Both cohort A and cohort B had significantly more displacement at crutch weight bearing compared with cohort C. The supplementary fixation group had significantly lower displacement at crutch weight-bearing compared with cohort A in all gaps. Survival curves demonstrated the fixation cohort to survive higher loads than the nonfixation group. CONCLUSION There was significantly less displacement and less failure of intra-articular distal radius fractures treated with a spanning dorsal bridge plate and supplementary fixation. Our model showed that either type of fixation was superior to the nonfixation group. CLINICAL SIGNIFICANCE When considering early weight-bearing for intra-articular distal radius fractures treated with a spanning dorsal bridge plate, supplementary fixation may be considered as an augmentation to prevent fracture displacement.
Collapse
Affiliation(s)
- Jacob M Modest
- Department of Orthopedic Surgery, Alpert Medical School of Brown University, Providence, RI.
| | - Jeremy E Raducha
- Department of Orthopedic Surgery, Alpert Medical School of Brown University, Providence, RI
| | | | - Janine Molino
- Department of Orthopedic Surgery, Alpert Medical School of Brown University, Providence, RI
| | - Christopher J Got
- Department of Orthopedic Surgery, Alpert Medical School of Brown University, Providence, RI
| | - Julia A Katarincic
- Department of Orthopedic Surgery, Alpert Medical School of Brown University, Providence, RI
| | - Joseph A Gil
- Department of Orthopedic Surgery, Alpert Medical School of Brown University, Providence, RI
| |
Collapse
|
3
|
DeFazio MW, Godfrey N, Offord E, Budis E, Olson N, Jones M. Distal Radius Fracture Outcomes After Dorsal Spanning Plate Fixation. Hand (N Y) 2024; 19:1120-1124. [PMID: 37085975 PMCID: PMC11483764 DOI: 10.1177/15589447231163942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/23/2023]
Abstract
BACKGROUND Dorsal spanning plate fixation can be used to treat comminuted distal radius fractures not amenable to volar plating. However, there is a relative paucity of outcomes data; so, the aim of this retrospective study was to investigate outcomes and complications after dorsal spanning plate fixation for distal radius fractures. METHODS Distal radius fractures treated with dorsal spanning plate fixation at a level-1 trauma center were retrospectively identified via Current Procedural Terminology coding and chart review from 2014 to 2019. Patient demographics, fracture pattern characteristics, fixation techniques, and clinical outcomes were all obtained via chart review using the electronic medical record. RESULTS In all, 43 dorsal plates were identified out of 369 operatively treated distal radius fractures (12%). Of these, 84% were AO type C, 28% were open fractures, and 86% resulted from falls. At the time of dorsal plating, 28% had an additional procedure. One patient had a major complication after surgery, requiring unplanned surgery for a radius nonunion. Average final follow-up occurred 9 weeks after dorsal plate removal, with mean range of motion at the wrist measuring: 36° flexion, 48° extension, 75° pronation, and 63° supination. Finger flexion was also measured, using either tip of finger to palm distance or total active motion, depending on the available data. These were measured at an average of 1.2 cm and 194°, respectively. CONCLUSIONS Dorsal spanning plate fixation provides a safe and effective method for treating complex distal radius fractures. In our series, patients had good functional outcomes with few complications.
Collapse
Affiliation(s)
| | - Natalie Godfrey
- UMass Memorial Medical Center/UMass Chan Medical School, Worcester, USA
| | - Evan Offord
- UMass Memorial Medical Center/UMass Chan Medical School, Worcester, USA
| | - Emmanuel Budis
- UMass Memorial Medical Center/UMass Chan Medical School, Worcester, USA
| | - Nathanael Olson
- UMass Memorial Medical Center/UMass Chan Medical School, Worcester, USA
| | - Marci Jones
- UMass Memorial Medical Center/UMass Chan Medical School, Worcester, USA
| |
Collapse
|
4
|
Drummond I, Durand-Hill M, Jones N, O'Hagan PJ, Edwards D. Systematic review: dorsal bridge plating in distal radius fractures. Musculoskelet Surg 2024; 108:359-366. [PMID: 38967772 PMCID: PMC11371870 DOI: 10.1007/s12306-024-00822-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 05/03/2024] [Indexed: 07/06/2024]
Abstract
PURPOSE Distal radius fractures are the most common upper limb fractures in adults (up to 18% of all fractures in the Emergency Department). Conservative management is possible for the majority, the preferred surgical technique being volar plate fixation. Dorsal bridge plating (DBP) is an alternative method of treatment for complex fractures. DBP acts as an internal fixator and can be used in patients needing early rehabilitation. This systematic review assesses the demographics, functional and radiological outcomes and complications of using DBP in patients with distal radius fractures compared to volar plate fixation. METHODS A literature search of PubMed, Cochrane, EMBASE and Google Scholar was performed according to PRISMA guidelines. Seven hundred and sixty-one articles were found; 11 articles met the inclusion criteria. Cadaveric studies and case studies of less than five patients were excluded. Primary outcome measures were functional and radiological outcomes. Complications were recorded as secondary outcomes. RESULTS Three hundred and ninety-four patients were included in the study with an average age of 54.8 years (53.9% male and 46.1% female). Weighted mean follow-up was 55.2 weeks; the mean time to plate removal was 17.3 weeks with a mean DASH score of 25.7. The weighted range of movement was 46.9° flexion, 48.8° extension, 68.4° pronation and 67.5° supination. The radiological parameters show satisfactory outcomes with a mean radial height of 10mm, volar tilt of 3.1°, ulnar variance of 0.5mm and radial inclination of 18.8°. The complication rate was 11.4%. Digital stiffness was the most common complication but improved if tenolysis was performed at plate removal. CONCLUSIONS DBP is a good alternative to volar plating for complex distal radius fractures. The functional outcomes showed a slight loss of range of movement, whereas the radiological outcomes were within recommended limits. A significant disadvantage of the plate is the need for further surgical removal.
Collapse
Affiliation(s)
- I Drummond
- Royal London Hospital, Barts Health NHS Trust, London, UK.
| | - M Durand-Hill
- Royal London Hospital, Barts Health NHS Trust, London, UK
| | - N Jones
- Royal London Hospital, Barts Health NHS Trust, London, UK
| | - P J O'Hagan
- Royal London Hospital, Barts Health NHS Trust, London, UK
| | - D Edwards
- Royal London Hospital, Barts Health NHS Trust, London, UK
- Centre for Neuroscience, Surgery and Trauma within Blizard Institute, Queen Mary University of London, London, UK
| |
Collapse
|
5
|
Cady-McCrea C, Brodell JD, Carroll TJ, Patel U, Dondapati A, Soin S, Ketz J. Adjunctive dorsal spanning plate fixation for challenging distal radius injuries. J Orthop 2024; 54:5-9. [PMID: 38516390 PMCID: PMC10950736 DOI: 10.1016/j.jor.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/25/2024] [Accepted: 03/03/2024] [Indexed: 03/23/2024] Open
Abstract
Background Distal radius fractures with severely osteoporotic bone or articular comminution can provide challenges to fixation with traditional volar locked plating alone. The purpose of this study was to evaluate the clinical, radiographic, and patient reported outcomes of patients undergoing distal radius fixation with volar locked plating and adjunctive dorsal bridge plating. Methods We retrospectively identified 16 patients with distal radius fractures who underwent our preferred surgical technique for fixation. Patients underwent volar locked plate fixation as well as dorsal bridge fixation at time of surgery. Seven patients were indicated for severe articular comminution with volar rim fragmentation (44%), three patients were revised for nonunion after previous volar locked late fixation (19%), and six patients had severely osteoporotic bone with articular comminution (38%). Two patients (13%) sustained AO/OTA 23-A3 distal radius fracture, two patients (13%) had a 23-B3 fracture, two patients (13%) had a 23-C2 fracture and ten patients (63%) had a 23-C3 fracture. Results The average patient age was 51.8 years ± 20.6. Patients were followed for an average of 12.2±6.3 months. The dorsal bridge plate was removed at an average of 11.1±2.4 weeks. The average post-operative radial inclination was 18.9±2.4°, radial height 12.4 mm ± 2.6 mm, and volar tilt 7.1±1.9°. There were no cases of deep or superficial infection. After dorsal bridge plate removal, patients demonstrated an average wrist extension of 55.3±9.5°, flexion 54.4±12.8°, radial deviation 15.7±3.2°, 25.2±3.9 degrees of ulnar deviation. Conclusion Distal radius fractures in the setting of severely osteoporotic bone, salvage procedures, articular comminution, volar rim fractures, and revision surgery present uniquely difficult surgical challenges. Volar locked plating with adjunctive dorsal bridge plating can be used with good short- and long-term results.
Collapse
Affiliation(s)
- Clarke Cady-McCrea
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| | - James D. Brodell
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| | - Thomas J. Carroll
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| | - Urvi Patel
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| | - Akhil Dondapati
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| | - Sandeep Soin
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| | - John Ketz
- University of Rochester Department of Orthopaedic Surgery, University of Rochester School, Rochester, NY, USA
| |
Collapse
|
6
|
Emmert AS, Swenson AK, Matar RN, Ross PR, Stern PJ. Characterization of Major Complications of Bridge Plating of Distal Radius Fractures at a Level I Trauma Center. Hand (N Y) 2024:15589447241257964. [PMID: 38869067 PMCID: PMC11571364 DOI: 10.1177/15589447241257964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
BACKGROUND Comminuted, markedly displaced distal radius fractures can cause instability requiring advanced stabilization with dorsal bridge plating. However, published complication rates of bridge plating widely vary. We hypothesize that complications of bridge plating of distal radius fractures are more prevalent than published rates. METHODS A retrospective review was performed on all patients at an academic level I trauma center treated with a bridge plate for a distal radius fracture from 2014 to 2022. RESULTS Sixty-five wrists were included in the final analysis: average age 53 years, male 51%, average plate retention 4 months, and average follow-up 6 months. Carpal tunnel release (CTR) was performed at time of primary procedure in 7 (10%) cases. Radial height, radial inclination, dorsal tilt, and ulnar variance were all significantly improved (P < .001). Grip strength, flexion, extension, and supination were significantly limited (P < .03). Twenty-one patients (32%) developed 35 major complications requiring unplanned reoperation, including mechanical hardware-related complication (15%), deep infection (11%), nonunion/delayed union (9%), adhesions (6%), median neuropathy (6%), symptomatic arthritis (5%), and tendon rupture (2%). Plate breakage occurred in 3 patients (5%) and was always localized over the central drill holes of the bridge plate. CONCLUSIONS Major complications for bridge plating of distal radius fractures were higher at our institution than previously published. Plate breakage should prompt reconsideration of plate design to avoid drill holes over the wrist joint. Signs and symptoms of carpal tunnel syndrome should be carefully assessed at initial presentation, and consideration for concomitant CTR should be strongly considered.
Collapse
|
7
|
Esworthy GP, Shaji V, Duraku L, Wu F, Power DM. Bridge Plate Distraction for Complex Distal Radius Fractures: A Cohort Study and Systematic Review of the Literature. J Wrist Surg 2024; 13:282-292. [PMID: 38808186 PMCID: PMC11129887 DOI: 10.1055/s-0043-1770791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 05/22/2023] [Indexed: 05/30/2024]
Abstract
Background Dorsal bridge plating (DP) of the distal radius is used as a definitive method of stabilization in complex fracture configurations and polytrauma patients. Questions/Purposes This review aims to summarize the current understanding of DP and evaluate surgical outcomes. Methods Four databases were searched following the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines and registered with PROSPERO. Papers presenting outcome or complication data for DP were included. These were reviewed using the National Institutes of Health Quality Assessment and Methodological Index for Non-Randomised Studies tools. Results were collated and compared to a local cohort of DP patients. Results Literature review identified 416 patients with a pooled complication rate of 17% requiring additional intervention. The most prevalent complications were infection/wound healing issues, arthrosis, and hardware failure. Average range of motion was flexion 46.5 degrees, extension 50.7 degrees, ulnar deviation 21.4 degrees, radial deviation 17.3 degrees, pronation 75.8 degrees, and supination 72.9 degrees. On average, DP removal occurred at 3.8 months. Quality assessment showed varied results. There were 19 cases in our local cohort. Ten displayed similar results to the systematic review in terms of range of motion and radiographic parameters. Higher QuickDASH scores and complication rates were noted. Local DP showed earlier plate removal at 2.9 months compared to previous studies. Conclusion DP is a valid and useful technique for treating complex distal radius fractures. It displays a lower risk of infection and pain compared to external fixation which is commonly used to treat similar injuries. Patients can recover well following treatment both in function and range of motion. Further high-quality studies are required to fully evaluate the technique.
Collapse
Affiliation(s)
- George P. Esworthy
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
- Leicester Medical School, University of Leicester, Leicester, United Kingdom
| | - Vibha Shaji
- Leicester Medical School, University of Leicester, Leicester, United Kingdom
| | - Liron Duraku
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
- Department of Plastic, Reconstructive and Hand Surgery, Amsterdam UMC, Amsterdam, Netherlands
| | - Feiran Wu
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
| | - Dominic M. Power
- Birmingham Hand Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Untied Kingdom
| |
Collapse
|
8
|
Carroll TJ, Dondapati A, Malin M, Ketonis C, Hammert W, Gonzalez R. Clinical and Radiographic Outcomes Following Volar-Locked Plating Versus Dorsal Bridge Plating for Distal Radius Factures. JOURNAL OF HAND SURGERY GLOBAL ONLINE 2024; 6:227-232. [PMID: 38903832 PMCID: PMC11185889 DOI: 10.1016/j.jhsg.2023.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 11/23/2023] [Indexed: 06/22/2024] Open
Abstract
Purpose Distal radius fractures (DRFs) indicated for operative intervention are most commonly treated with volar-locked plating (VLP); however, dorsal bridge plating (DBP) has been used as an alternative fixation method. The purpose of this study was to use a propensity score to match and compare the radiographic and clinical outcomes of patients undergoing isolated VLP or DBP for DRFs. Methods We performed a retrospective, propensity score-matched analysis of patients undergoing isolated VLP or DBP treatment for isolated DRFs from 2015 to 2022 at a single level-1 trauma center. Patients were propensity score-matched by a total of eight demographic and comorbidity factors, AO Foundation/Orthopedic Trauma Association classification, and preoperative Patient-Reported Outcomes Measurement Information System (PROMIS) scores. Our primary outcomes included postoperative complications, wrist and forearm range of motion (ROM), grip strength, and radiographic measurements, including radial height, radial inclination, volar tilt, and articular step-off. Results Overall, 415 DBP and 2075 VLP were successfully propensity score-matched and included in this study. Grip strength and ROM measurements at the 6-month follow-up, including wrist flexion, wrist extension, forearm pronation, forearm supination, radial deviation, and ulnar deviation, were increased in the VLP compared with DBP (P < .05). Complication rates among both the groups were relatively low; however, the rates of malunion and nonunion were significantly higher among the DBP group (P < .05). Radial height, radial inclination, and articular step-off were improved in the VLP group compared with the DBP group (P < .05); however, volar tilt was similar between groups. PROMIS upper extremity and physical function were significantly higher among the VLP group (P < .05). No significant difference was noted in PROMIS pain interference between the groups. Conclusions When compared with DBP, patients undergoing VLP are more likely to have improved clinical and radiographic outcomes. Although improvement in wrist and forearm ROM and radiographic parameters is statistically significant, it may not be clinically relevant. Type of study/level of evidence Therapeutic III.
Collapse
Affiliation(s)
- Thomas John Carroll
- Department of Orthopaedic Surgery, University of Rochester School, University of Rochester, Rochester, NY
| | - Akhil Dondapati
- Department of Orthopaedic Surgery, University of Rochester School, University of Rochester, Rochester, NY
| | - Michaela Malin
- Department of Orthopaedic Surgery, University of Rochester School, University of Rochester, Rochester, NY
| | - Constantinos Ketonis
- Department of Orthopaedic Surgery, University of Rochester School, University of Rochester, Rochester, NY
| | - Warren Hammert
- Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, NC
| | - Ronald Gonzalez
- Department of Orthopaedic Surgery, University of Rochester School, University of Rochester, Rochester, NY
| |
Collapse
|
9
|
Komura S, Hirakawa A, Hirose H, Yamamoto K, Matsushita Y, Matsumoto K, Akiyama H. Reconstruction of a severe comminuted distal radius fracture with a large segmental bone defect by dorsal bridge plating combined with a vascularized fibular graft: A case report. J Orthop Sci 2023; 28:1508-1512. [PMID: 34507872 DOI: 10.1016/j.jos.2021.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/04/2021] [Accepted: 08/18/2021] [Indexed: 11/13/2022]
Affiliation(s)
- Shingo Komura
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan.
| | - Akihiro Hirakawa
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Hitoshi Hirose
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Kyosuke Yamamoto
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Yasuharu Matsushita
- Department of Rehabilitation Medicine, Gifu University Hospital, Gifu, Japan
| | - Kazu Matsumoto
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| | - Haruhiko Akiyama
- Department of Orthopaedic Surgery, Gifu University Graduate School of Medicine, Gifu, Japan
| |
Collapse
|
10
|
Bradley H, Rodriguez J, Ahn J, Sammer D, Golden A, Koehler D. Evaluation of Radiographic Parameters Following Dorsal Wrist-Spanning Plate Fixation of Distal Radius Fractures to the Second Versus Third Metacarpal. J Hand Surg Am 2023; 48:1061.e1-1061.e6. [PMID: 35534327 DOI: 10.1016/j.jhsa.2022.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 01/26/2022] [Accepted: 03/04/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE Dorsal wrist-spanning plate fixation for comminuted, intra-articular distal radius fractures involves the indirect reduction of intra-articular fractures via ligamentotaxis. The reduction is maintained by application of a bridge plate from the radial diaphysis to either the second or third metacarpal. The objective of this study was to retrospectively compare radiographic outcomes between distal radius fractures managed with bridge plate fixation to the second versus third metacarpal. METHODS A single-institution retrospective review identified 50 cases of distal radius fractures that underwent dorsal wrist-spanning plate fixation, with 9 and 41 fractures undergoing fixation to the second and third metacarpals, respectively. Radiographic parameters, such as radial height, radial inclination, volar tilt, and ulnar variance, were measured at 3 time points: immediately after surgery, immediately prior to elective plate removal, and at the final follow-up. Radiographic measurements of the 2 cohorts were compared at the 3 time points. RESULTS Final radiographs showed an average radial height of 8.9 mm versus 9.4 mm for the second versus third metacarpal cohorts, respectively; average radial inclination of 17.4° for both the second and third metacarpal cohorts; average volar tilt of 1.9° versus 1.7° for the second versus third metacarpal cohorts, respectively; and an average ulnar variance of +0.6 mm versus +0.1 mm for the second versus third metacarpal cohorts, respectively. Radiographic parameters of the second and third metacarpal cohorts were similar across all the time points. Additionally, evaluation of the radiographic parameters across the 3 time points (immediately after surgery, immediately prior to elective plate removal, and at the final follow-up) demonstrated little to no loss of radiographic alignment. CONCLUSIONS Radiographic outcomes for distal radius fractures managed with bridge plate fixation to the second versus third metacarpal appear similar. The distal plate fixation site can likely be determined on the basis of fracture anatomy and patient-specific features. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.
Collapse
Affiliation(s)
- Hallie Bradley
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Joel Rodriguez
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Junho Ahn
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Douglas Sammer
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Ann Golden
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX
| | - Daniel Koehler
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, TX.
| |
Collapse
|
11
|
Fleifel D, Pytiak AV, Jin X, Cizmic Z, Vaidya R. Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures. Cureus 2023; 15:e39142. [PMID: 37332475 PMCID: PMC10275508 DOI: 10.7759/cureus.39142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2023] [Indexed: 06/20/2023] Open
Abstract
Background External fixators that span the wrist have been the historical norm in treating distal radius fractures. We have modified a dorsal distraction approach by using a subcutaneously applied locked bridge plate through two small incisions superficial to the extensor tendons and outside the extensor compartment. The purpose of this study was to biomechanically evaluate this modified method of fixation for comminuted distal radius fractures in comparison with two established constructs. Methods Matched cadaver specimens were used to model an AO Type 23-C3 distal radius fracture. Biochemical testing for stiffness during axial compressive loading was done on three constructs: a conventional Burke distraction plate, the subcutaneous internal fixation plating technique, and an external fixator. All specimens were cyclically loaded for 3000 cycles and then retested. Results The modified construct was found to be stiffer than the external fixator (p=0.013). When compared to the Burke plate, the modified construct was significantly less stiff before axial cycling (p=0.025). However, the difference was not maintained after cycling, and the post-axial loading stiffness difference was non-significant (p=0.456). Conclusion Our data demonstrate the biomechanical integrity of the subcutaneous plating technique for the fixation of comminuted distal radius fractures. It is stiffer than an external fixator and has the theoretical advantage of avoiding pin-tract infections. In addition, it is subcutaneous and not a cumbersome external construct. Our construct is minimally invasive, and it does not violate the dorsal extensor compartments. This allows for finger movement even while the construct is in place.
Collapse
Affiliation(s)
- Dominik Fleifel
- Department of Orthopaedic Surgery, Wayne State University School of Medicine, Detroit, USA
- Department of Orthopaedic Surgery, Detroit Medical Center, Detroit, USA
| | - Andrew V Pytiak
- Department of Pediatric Orthopaedic Surgery, Rocky Mountain Hospital for Children, Denver, USA
| | - Xin Jin
- Department of Biomedical Engineering, Wayne State University School of Medicine, Detroit, USA
| | - Zlatan Cizmic
- Department of Orthopaedic Surgery, St. John Providence Hospital, Southfield, USA
| | - Rahul Vaidya
- Department of Orthopaedic Surgery, Wayne State University School of Medicine, Detroit, USA
- Department of Orthopaedic Surgery, Detroit Medical Center, Detroit, USA
| |
Collapse
|
12
|
Tabeayo E, Saucedo JM, Srinivasan RC, Shah AR, Karamanos E, Rockwood J, Rodriguez-Merchan EC. Bridge plating in the setting of radiocarpal instability: Does distal fixation to the second or third metacarpal matter? A cadaveric study. World J Orthop 2023; 14:207-217. [PMID: 37155513 PMCID: PMC10122777 DOI: 10.5312/wjo.v14.i4.207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 02/15/2023] [Accepted: 03/24/2023] [Indexed: 04/18/2023] Open
Abstract
BACKGROUND Radiocarpal dislocations are rare but potentially devastating injuries. Poorer outcomes are associated with inadequate or lost reduction, such as ulnar translocation, but no consensus exists on the ideal fixation technique. Dorsal bridge plate fixation has been described for various settings in the treatment of complex distal radius fractures and can be fixed distally to the second or third metacarpal, but its application for radiocarpal dislocations has not been established. AIM To determine whether distal fixation to the second or third metacarpal matters. METHODS Using a cadaveric radiocarpal dislocation model, the effect of distal fixation was studied in two stages: (1) A pilot study that investigated the effect of distal fixation alone; and (2) a more refined study that investigated the effect of described techniques for distal and proximal fixation. Radiographs were measured in various parameters to determine the quality of the reduction achieved. RESULTS The pilot study found that focusing on distal fixation alone without changing proximal fixation results in ulnar translocation and volar subluxation when fixing distally to the second metacarpal compared with the third. The second iteration demonstrated that anatomic alignment in coronal and sagittal planes could be achieved with each technique. CONCLUSION In a cadaveric radiocarpal dislocation model, anatomic alignment can be maintained with bridge plate fixation to the second metacarpal or the third metacarpal if the described technique is followed. When considering dorsal bridge plate fixation for radiocarpal dislocations, the surgeon is encouraged to understand the nuances of different fixation techniques and how implant design features may influence proximal placement.
Collapse
Affiliation(s)
- Eloy Tabeayo
- Department of Orthopedic Surgery, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY 10461, United States
| | - James M Saucedo
- Houston Methodist Institute for Academic Medicine, Houston Methodist Orthopedics and Sports Medicine, Houston, TX 77479, United States
| | - Ramesh C Srinivasan
- Hand Center of San Antonio and the Department of Orthopedic Surgery, University of Texas Health Science Center, The Hand Center of San Antonio, San Antonio, TX 78240, United States
| | - Amita R Shah
- University of Texas Health Science Center at San Antonio, University of North Carolina at Chapel Hill, San Antonio, TX 78229, United States
| | - Efstathios Karamanos
- Surgeon in the Division of Acute Care Surgery in the Department of Surgery at Henry Ford Hospital in Detroit, UT Health San Antonio, San Antonio, TX 78229, United States
| | | | | |
Collapse
|
13
|
Izawa Y, Murakami H, Shirakawa T, Sato K, Yoshino T, Tsuchida Y. Distraction plating for bilaterally severely comminuted distal radius fracture: a case report. Case Reports Plast Surg Hand Surg 2023; 10:2165497. [PMID: 36685805 PMCID: PMC9848338 DOI: 10.1080/23320885.2023.2165497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
We report a case in which distraction plating was performed for bilateral highly comminuted distal radius fractures. The upper extremities' range of motion and function was acceptable. Thus, distraction plating can be a good option for relatively young patients with severe comminution of the radius and soft tissue damage.
Collapse
Affiliation(s)
- Yuta Izawa
- Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan,CONTACT Yuta Izawa Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Kita 33 jou Higashi 14 chome 3-1, Higashiku, Sapporo, Hokkaido, Japan
| | - Hiroko Murakami
- Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Tetsuya Shirakawa
- Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Kazuo Sato
- Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Toshiki Yoshino
- Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Yoshihiko Tsuchida
- Department of Orthopedic Trauma Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| |
Collapse
|
14
|
Roberts T, Kocialcowski C, Cowey A. Dorsal bridging plates for the treatment of high and low energy distal radius fractures. J Clin Orthop Trauma 2022; 35:102048. [PMID: 36340961 PMCID: PMC9634010 DOI: 10.1016/j.jcot.2022.102048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 09/13/2022] [Accepted: 10/18/2022] [Indexed: 11/06/2022] Open
Abstract
Distal radius fractures are common and treatment of complex fracture pattens can be challenging. We assessed functional outcomes, radiographic analysis, and complications of 26 distal radius fractures treated with dorsal bridging plate (DBP) at a mean of 14 months post plate removal (6-34 months). Radiographic parameters were measured pre- and post-operatively and patient reported wrist evaluation scores, patient reported wrist range of movement and satisfaction scores. Mean post-operative total PRWE was 26 (range 0-76) and mean wrist mobility 52° flexion (range 10°-85°) and 50° extension (range 10°-85°). Mean post-operative patient satisfaction score was 89% (range 50-100%). Four patients developed complications (one EPL rupture and three developed CRPS). DBP can reliably restore distal radius anatomy and is associated with good functional outcome scores, return of functional range of wrist movement and high levels of patient satisfaction. Level of Evidence III.
Collapse
Affiliation(s)
- Tobias Roberts
- Corresponding author. Trauma & Orthopaedic Department, St. George's Hospital, London, SW17 0QT, UK.
| | | | | |
Collapse
|
15
|
Mohamed MA, Abdel-Wanis ME, Said E, Abdel-Aziz IA, Ahmed AM, Addosooki A. Dorsal bridge plating versus bridging external fixation for management of complex distal radius fractures. Injury 2022; 53:3344-3351. [PMID: 35999066 DOI: 10.1016/j.injury.2022.08.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 07/27/2022] [Accepted: 08/07/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Distal radius fractures are the most frequent upper limb injuries encountered by orthopedic surgeons. Surgical treatment of distal radius fractures is preserved for unstable and displaced fractures. A randomized controlled trial was conducted to compare the radiological and functional outcomes of bridge plating (BP) to external fixation (EF) in comminuted intra-articular distal radius fractures. METHODS Sixty patients with distal radius fractures were eligible for treatment by means of ligamentotaxis using either a dorsal bridge plate (30 patients) or an external fixator (30 patients) with or without supplementary Kirschner wires (K-wires). Radiological evaluation was done using the radial inclination angle, radial length, and the volar tilt. Clinical evaluation was performed using ranges of wrist motion, grip strength, Visual Analogue Scale (VAS), and a validated Arabic version of the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire RESULTS: Patients were followed up for 12 months. No significant difference was found in terms of radiographic parameters or ranges of wrist motion. At 3-months follow-up, bridge plating group had stronger grip strength, lower Disability of the Arm, Shoulder, and Hand scores, and lower Visual Analogue Scale. However, both groups had similar functional outcomes at last follow-up. External fixation group had a higher rate of postoperative complications. CONCLUSION In comparison to external fixation, bridge plating may provide earlier functional recovery with lower complication rates. However, no functional or radiological superiority were demonstrated at 12-months follow-up.
Collapse
Affiliation(s)
- Mohamed A Mohamed
- Department of Orthopaedic Surgery and Traumatology, Sohag Faculty of Medicine, Sohag University, Sohag, Egypt
| | - Mohamed E Abdel-Wanis
- Department of Orthopaedic Surgery and Traumatology, Sohag Faculty of Medicine, Sohag University, Sohag, Egypt
| | - Elsayed Said
- Department of Orthopaedic Surgery and Traumatology, Qena Faculty of Medicine, South Valley University, Qena, Egypt
| | - Islam A Abdel-Aziz
- Department of Orthopaedic Surgery and Traumatology, Sohag Faculty of Medicine, Sohag University, Sohag, Egypt
| | - Ahmed M Ahmed
- Department of Orthopaedic Surgery and Traumatology, Qena Faculty of Medicine, South Valley University, Qena, Egypt.
| | - Ahmad Addosooki
- Department of Orthopaedic Surgery and Traumatology, Sohag Faculty of Medicine, Sohag University, Sohag, Egypt
| |
Collapse
|
16
|
Raducha JE, Hresko A, Molino J, Got CJ, Katarincic J, Gil JA. Weight-Bearing Restrictions With Distal Radius Wrist-Spanning Dorsal Bridge Plates. J Hand Surg Am 2022; 47:188.e1-188.e8. [PMID: 34023193 DOI: 10.1016/j.jhsa.2021.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 01/29/2021] [Accepted: 04/05/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE The fixation of comminuted distal radius fractures using wrist-spanning dorsal bridge plates has been shown to have good postoperative results. We hypothesized that using a stiffer bridge plate construct results in less fracture deformation with loads required for immediate crutch weight bearing. METHODS We created a comminuted, extra-articular fracture in 7 cadaveric radii, which were fixed using dorsal bridge plates. The specimens were positioned to simulate crutch/walker weight bearing and axially loaded to failure. The axial load and mode of failure were measured using 2- and 5-mm osteotomy deformations as cutoffs. Bearing 50% and 22% of the body weight was representative of the force transmitted through crutch and walker weight bearing, respectively. RESULTS The load to failure at 2-mm deformation was greater than 22% body weight for 2 of 7 specimens and greater than 50% for 1 of 7 specimens. The load to failure at 5-mm deformation was greater than 22% body weight for 6 of 7 specimens and greater than 50% for 4 of 7 specimens. The mean load to failure at 2-mm gap deformation was significantly lower than 50% body weight (110.4 N vs 339.2 N). The mean load to failure at 5-mm deformation was significantly greater than 22% body weight (351.8 N vs 149.2 N). All constructs ultimately failed through plate bending. CONCLUSIONS All constructs failed by plate bending at forces not significantly greater than the 50% body weight force required for full crutch weight bearing. The bridge plates supported forces significantly greater than the 22% body weight required for walker weight bearing 6 of 7 times when 5 mm of deformation was used as the failure cutoff. CLINICAL RELEVANCE Elderly, walker-dependent patients may be able to use their walker as tolerated immediately after dorsal bridge plate fixation for extra-articular fractures. However, patients should not be allowed to bear full weight using crutches immediately after bridge plating.
Collapse
Affiliation(s)
- Jeremy E Raducha
- Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI.
| | | | - Janine Molino
- Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI
| | - Christopher J Got
- Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI; University Orthopedics Incorporated, Providence, RI
| | - Julia Katarincic
- Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI; University Orthopedics Incorporated, Providence, RI
| | - Joseph A Gil
- Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI; University Orthopedics Incorporated, Providence, RI
| |
Collapse
|
17
|
Abstract
The management of distal radius fractures has evolved considerably in the last two decades. Techniques and hardware have improved so much that the surgeon can usually assure good results in these debilitating fractures. Yet no one method can be used for all injuries, as the personality of each fracture demands a customized approach. Furthermore, what works in one age group may not work in another. For this reason, every available treatment has its own space in our options. The need for surgeons to be well versed in all techniques is critical. We offer a concise update of important evolutionary and current treatment guidelines for this common fracture.
Collapse
Affiliation(s)
| | - Jesse B Jupiter
- Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Tamara D Rozental
- Harvard Medical School, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Rohit Arora
- Department of Orthopaedics and Traumatology, Medical University Innsbruck, Innsbruck, Austria
| | - Toshiyasu Nakamura
- Department of Orthopaedic Surgery, International University of Health and Welfare, Tokyo, Japan
| | - Gregory I Bain
- Department of Orthopaedic Surgery, Flinders University, Adelaide, Australia
| |
Collapse
|
18
|
Wahl EP, Lauder AS, Pidgeon TS, Guerrero EM, Ruch DS, Richard MJ. Dorsal Wrist Spanning Plate Fixation for Treatment of Radiocarpal Fracture-Dislocations. Hand (N Y) 2021; 16:834-842. [PMID: 31847582 PMCID: PMC8647312 DOI: 10.1177/1558944719893068] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
Abstract
Background: Radiocarpal dislocations are rare injuries that result from high-energy forces across the wrist with the hallmark finding of radiocarpal ligament disruption. Published treatment methods are comprehensive with moderate-to-good outcomes. The purpose of this study was to review the treatment of radiocarpal dislocations with a dorsal wrist spanning plate. Methods: A retrospective review was conducted analyzing the radiographic and clinical outcomes of patients treated for a radiocarpal dislocation using a dorsal wrist spanning plate over a 10-year period. Outcomes assessed included radiographic joint incongruity and arthrosis, wrist range of motion, grip strength, Visual Analogue Scale (VAS) score, surgical complications, and Disabilities of the Arm, Shoulder, and Hand (DASH) score. Results: Thirteen patients were treated with a dorsal wrist spanning plate for radiocarpal dislocation with a mean follow-up of 615 days from the time of initial surgery. Six patients (46%) had associated distal radioulnar joint instability. The mean wrist range of motion at the final follow-up was: flexion 39°, extension 44°, pronation 79°, and supination 84°. One patient (8%) developed ulnar translation of the carpus, and 11 patients (85%) developed radiographic posttraumatic wrist arthrosis. Mean VAS and DASH scores were 4 and 18, respectively. Conclusions: Acute treatment with a dorsal wrist spanning plate in this series resulted in comparable outcomes to what have been previously reported in the literature. The dorsal wrist spanning plate offers the surgeon a reliable method of stabilization, with minimal additional surgical trauma to the wrist, while avoiding the potential for infections that develop with other treatment methods.
Collapse
Affiliation(s)
- Elizabeth P. Wahl
- Duke University Medical Center, Durham, NC, USA,Elizabeth P. Wahl, Department of Orthopaedic Surgery, Duke University Medical Center, 4709 Creekstone Drive, Suite 200, Durham, NC, 27703, USA.
| | | | | | | | | | | |
Collapse
|
19
|
Distal Radius Fractures: Setting Yourself Up for Success in the Active Geriatric Patient. J Orthop Trauma 2021; 35:S16-S20. [PMID: 34533497 DOI: 10.1097/bot.0000000000002226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/10/2021] [Indexed: 02/02/2023]
Abstract
Distal radius fractures are common in the geriatric population; however, treatment of these fractures remains controversial. Patients undergoing operative fixation may experience a quicker recovery with increased grip strength, which is beneficial in the active geriatric patient. Treatment options include fragment-specific fixation, volar locked plating, and dorsal bridge plating. External fixation alone leads to poor outcomes and is indicated in patients with soft tissue compromise or as a supplemental aid. Implant selection should be tailored to fracture parameters. With a thoughtful surgical algorithm and rehabilitation protocol, good outcomes can be achieved with a high rate of patient satisfaction.
Collapse
|
20
|
Distal Radius Fractures and the Dorsal Spanning Plate in the Management of the Polytraumatized Patient. J Orthop Trauma 2021; 35:s6-s10. [PMID: 34415875 DOI: 10.1097/bot.0000000000002204] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/08/2021] [Indexed: 02/02/2023]
Abstract
Distal radius fractures are some of the most common fractures treated by the orthopaedic surgeon. There are a variety of methods of fixation to treat these fractures; however, in patients with polytrauma and in high-energy fracture patterns, fixation options can be limited. In the past, these fractures were treated with plaster, Kirschner wires, or external fixators that were fraught with complications. The dorsal spanning plate is an excellent option in the treatment of high-energy fractures and patients with polytrauma, fractures with dorsal or volar comminution, fracture dislocations, and shear injuries, and in geriatric patients with poor bone quality. The dorsal spanning plate not only allows for fixation of these complex fractures but also allows for weight-bearing through the wrist, an advantage for patients with concomitant lower extremity fractures and geriatric patients who need mobility aides. Understanding the risks and benefits of dorsal spanning plates and their use for the treatment of polytraumatized patient is a vital base of knowledge for the orthopaedic traumatologist.
Collapse
|
21
|
Fares AB, Childs BR, Polmear MM, Clark DM, Nesti LJ, Dunn JC. Dorsal Bridge Plate for Distal Radius Fractures: A Systematic Review. J Hand Surg Am 2021; 46:627.e1-627.e8. [PMID: 33573844 DOI: 10.1016/j.jhsa.2020.11.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 09/20/2020] [Accepted: 11/24/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE This study presents patient demographics, injury characteristics, outcomes, and complications associated with dorsal bridge plating (DBP) in the treatment of distal radius fractures. METHODS A literature search performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines identified 206 articles, 12 of which met inclusion criteria, accounting for 310 patients. Included articles contained the results of DBP for treatment of distal radius fractures with reported outcomes between 1988 and 2018. Data were pooled and analyzed focusing on patient demographics, as well as 3 primary outcomes of complications, range of motion (ROM), and Disabilities of the Arm, Shoulder, and Hand (DASH) and QuickDASH scores. RESULTS Average age was 55 years, median follow-up was 24 months, and the most common use was in comminuted (92%) intra-articular (92%) distal radius fracture caused by fall (58%), or motor vehicle collision or motorcycle collision (27%). A minority of patients had open fractures (16%) and most were cases of polytrauma (65%). Median time from placement to DBP removal was 17 weeks (mean, 119 days). At final follow-up, mean wrist ROM was 45° flexion, 50° extension, 75° pronation, and 73° supination. Mean DASH score was 26.1, and mean QuickDASH score was 19.8. The overall rate for any complication was 13%; the most common was hardware failure (3%) followed by symptomatic malunion or nonunion (3%), and persistent pain after hardware removal (2%). CONCLUSIONS Dorsal bridge plating was found to be used most commonly in intra-articular, comminuted distal radius fractures with overall functional wrist ROM, moderate patient-reported disability, and a 13% complication rate at follow-up. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.
Collapse
Affiliation(s)
- Austin B Fares
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX.
| | - Benjamin R Childs
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX
| | - Michael M Polmear
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX
| | - DesRaj M Clark
- Department of Clinical and Experimental Orthopaedics, Walter Reed National Military Medical Center, Bethesda, MD
| | - Leon J Nesti
- Department of Clinical and Experimental Orthopaedics, Walter Reed National Military Medical Center, Bethesda, MD
| | - John C Dunn
- Department of Orthopaedic Surgery, William Beaumont Army Medical Center, El Paso, TX
| |
Collapse
|
22
|
Azad A, Choi JT, Fisch R, Gipsman A, Nicholson LT, Ghiassi A. Wrist-Spanning Fixation of Radiocarpal Dislocation: A Cadaveric Assessment of Ulnar Translation. Hand (N Y) 2021; 16:482-490. [PMID: 31517519 PMCID: PMC8283113 DOI: 10.1177/1558944719873148] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: Radiocarpal dislocations represent a high-energy wrist injury that can occur with or without concomitant fractures about the wrist. Poor outcomes are often due to radiocarpal instability and secondary ulnar translation. The purpose of this cadaveric study is to determine if there is any difference in the radiographic parameters in a wrist dislocation model given the different location of distal fixation. Methods: Ten paired fresh cadaver upper extremities were fluoroscopically evaluated with posterior-anterior (PA) and lateral views. We created a radiocarpal dislocation model and applied a dorsal bridge plate to either the second or third metacarpal. Repeat PA and lateral fluoroscopic views were obtained for evaluation of radial inclination, radial height, volar tilt, ulnar variance, radiolunate angle, radioscaphoid angle, scapholunate angle, radial rotation index, and four indices for ulnar translation (Taleisnik, Gilula, McMurtry, and Chamay). Results: Bridge plate application to the second metacarpal resulted in a significantly greater incidence of ulnar translation compared to the third metacarpal. Application to either metacarpal resulted in extension of the carpus relative to the radius. Conclusions: A more anatomic radiocarpal relationship was restored more often when distal fixation of the dorsal wrist-spanning bridge plate was applied to the third metacarpal. Further investigation is warranted to determine clinical relevance of these findings in conjunction with clinical and radiographic outcomes.
Collapse
Affiliation(s)
- Ali Azad
- Keck Medical Center of University of Southern California, Los Angeles, USA,Ali Azad, Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, 1200 N. State Street, GNH 3900, Los Angeles, CA 90033, USA.
| | - Jihoon Tony Choi
- Keck Medical Center of University of Southern California, Los Angeles, USA
| | - Robert Fisch
- Keck Medical Center of University of Southern California, Los Angeles, USA
| | - Aaron Gipsman
- Keck Medical Center of University of Southern California, Los Angeles, USA
| | | | - Alidad Ghiassi
- Keck Medical Center of University of Southern California, Los Angeles, USA
| |
Collapse
|
23
|
The spanning plate as an internal fixator in complex distal radius fractures: a prospective cohort study. Eur J Trauma Emerg Surg 2021; 48:2369-2377. [PMID: 34185106 DOI: 10.1007/s00068-021-01738-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 06/19/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Minimal invasive temporary spanning plate (SP) fixation of the wrist has been described as an alternative treatment method in complex distal radius fractures (DRFs). The purpose of this study is to conduct an outcome analysis of all consecutive DRFs treated by SP fixation representing the so far largest published patient cohort outside the United States. METHODS Indication for SP fixation include DRFs with severe metaphyseal comminution, radiocarpal fracture dislocations with concomitant ligamentous injuries and very distal intra-articular fractures lacking the possibility of adequate plate anchoring. All consecutive patients undergoing SP fixation of DRFs were prospectively included in a single level I trauma centre between 01/01/2018 and 31/12/2020. For functional and patient-rated outcome analysis only patients who completed the 12 month follow-up were included. RESULTS In the mentioned timeframe, a total of 562 DRFs were treated operatively of which 28 underwent SP fixation. Average age was 58.1 years (range 22-95 years). The fracture type ranged from AO/OTA type B1.1 to C3.3 and included 8 fracture dislocations. SP removal was performed on average 3.7 months after the initial operation (range 1.4-6.5 months). Twenty-five patients completed the 12 month follow-up (mean 14.5 months, range 12-24). Radiological evidence of fracture healing appeared on average 9.9 weeks (range 5-28 weeks) after the initial operation. One patient experienced asymptomatic non-union. Mean radial inclination, volar tilt and ulnar variance at 1 year were all within the acceptable limit predictive of symptomatic malunion. Complications included two patients with tendon rupture and one patient with extensor tendon adhesions needing tenolysis at the time of plate removal leaving an overall complication rate of 12%. There was no implant failure and no infection. Mean satisfaction score was 8.3 (range 4-10) and mean visual analogue scale for resting pain was 0.8 (range 0-5). The mean PRWE score was 17.9 (range 0-59.5) and the mean DASH score was 16.6 (range 0-60.8). Grip strength averaged 23 kg (range 4-74 kg) amounting to 68% of the opposite side. Range of motion regarding the extension/flexion, radial/ulnar abduction and pronation/supination arc reached 72%, 77% and 95% compared to the unaffected side, respectively. CONCLUSIONS The radiological, functional and patient-rated outcomes in this study are remarkably good considering the complexity of the included fractures. Therefore, this method represents a valuable alternative for the treatment of complex DRFs in selected patients.
Collapse
|
24
|
Henry TW, Tulipan JE, McEntee RM, Beredjiklian PK. Early Retrieval of Spanning Plates Used for Fixation of Complex Fractures of the Distal Radius. J Wrist Surg 2021; 10:229-233. [PMID: 34109066 PMCID: PMC8169165 DOI: 10.1055/s-0040-1722573] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 11/27/2020] [Indexed: 10/22/2022]
Abstract
Background Spanning plates are being increasingly used for the treatment of complex fractures of the distal radius. The traditional recommendation is to leave the hardware in place for at least 12 weeks. Questions/Purpose This study assesses the comparative outcomes of spanning plates removed at or before 10 weeks. We hypothesized that acceptable healing and functional outcomes can be achieved with earlier hardware removal to allow for earlier range of motion, rehabilitation, and return to function. Patients and Methods All patients treated for a comminuted, intra-articular distal radius fracture with a temporary spanning plate were identified. Outcomes of bridge plates removed before 10 weeks were compared with plates removed after 12 weeks. Twenty patients in the short duration cohort were compared with 40 patients in the long duration cohort. Results All fractures healed and there were 10 complications (4 short duration, 6 long duration) and 2 reoperations (1 short duration, 1 long duration) in the study population. There were no significant differences in final Quick-DASH scores (27.4 short duration, 20.9 long duration) or radiographic alignment. Mean values for wrist extension and ulnar deviation were significantly worse in the long duration cohort, although these differences are of unclear clinical significance. Conclusion It may be safe to remove spanning bridge plates earlier than what is traditionally recommended. Plate removal at or before 10 weeks did not detract from healing or radiographic alignment. Prospective investigations assessing the optimal duration of fixation for this technique are needed. Level of Evidence This is a Level IV study.
Collapse
Affiliation(s)
- Tyler W. Henry
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Jacob E. Tulipan
- Department of Hand and Wrist Surgery, Rothman Orthopaedic Institute, Philadelphia, Pennsylvania
| | - Richard M. McEntee
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Pedro K. Beredjiklian
- Department of Hand and Wrist Surgery, Rothman Orthopaedic Institute, Philadelphia, Pennsylvania
| |
Collapse
|
25
|
Temporary spanning plate wrist fixation of complex distal radius fractures: a systematic review of 353 patients. Eur J Trauma Emerg Surg 2021; 48:1649-1662. [PMID: 33900417 DOI: 10.1007/s00068-021-01656-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 03/21/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Temporary spanning plate fixation of the wrist has been described as an alternative treatment method for complex distal radius fractures (DRfs). This systematic review aims to gain insight on clinical and radiological outcomes of this technique currently published in literature. METHODS A comprehensive literature search of Pubmed, Embase, CENTRAL and CINAHL databases was conducted on November 5th 2020. All studies reporting on complications, functional, patient-rated and radiological outcomes of temporary spanning plate wrist fixation of DRFs in adult patients were included. RESULTS Two prospective and eight retrospective cohort studies were included encompassing 353 patients with of 357 DRFs. The overall mean age was 53 years (range 19-95 years). Overall mean follow-up ranged from 6 months to 8.8 years. The union rate was 99.4%. Plate removal was performed on average 4.5 months after initial operation (range 1.1-28.9 months). The most frequently reported complication was implant failure with an incidence of 3.1%. Mean flexion/extension, pronation/supination and radial/ulnar inclination arc averaged 96.6°, 151.5° and 36.5°, respectively. Grip strength averaged 79.7% of the contralateral side. Mean DASH and PRWE scores were 22.9 and 16 points, respectively. Radiological indices were all within the acceptable limits. CONCLUSIONS Temporary spanning plate wrist fixation is a safe method for the treatment of complex DRFs. This technique can exploit the advantages of temporary wrist immobilization without the disadvantages of external fixation. With these aspects in mind, the spanning plate can serve as a valuable tool in the treatment of complex intra-articular DRFs.
Collapse
|
26
|
Carula BC, Pereira MDS, Ferreira APB, Ayzemberg H, Steglich V, Stangarlin TS. Analysis of the Clinical and Radiological Results of Bridge Plate Versus External Fixation in Comminuted Distal Radius Fractures. Rev Bras Ortop 2021; 56:61-68. [PMID: 33627901 PMCID: PMC7895615 DOI: 10.1055/s-0040-1713393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Accepted: 04/15/2020] [Indexed: 11/18/2022] Open
Abstract
Objective To evaluate and compare the clinical and radiological outcomes of patients with comminuted distal radius fractures treated with an external fixator or a dorsal bridge plate. Methods In total, 45 patients were analyzed 1 year after surgery; 18 were treated with an external fixator, and 25 received a dorsal bridge plate. An analog pain scale and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire were applied, in addition to radiographic, strength and range of motion assessments. Statistical analyzes were performed using the chi-squared test and the Mann-Whitney non-parametric test. Results Fractures were more common in women over 60 years old who suffered falls from their own height. Both methods demonstrated similar functional and radiological results. Infections were more prevalent in patients receiving external fixators, but their residual grip strength was better. Reflex sympathetic neuropathy was more common in subjects treated with a dorsal bridge plate. Conclusion Our analysis showed no consensus on the superiority of one method over the other. Each method had advantages and disadvantages, but both led to good, similar outcomes. The treatment must be chosen according to the profile of the trauma, the patient's clinical conditions, the surgeon's experience, and the availability of materials.
Collapse
Affiliation(s)
- Beatriz Canhoto Carula
- Instituto de Ortopedia e Traumatologia de Joinville, Hospital Municipal São José, Joinville, SC, Brasil
| | - Matheus da Silva Pereira
- Instituto de Ortopedia e Traumatologia de Joinville, Hospital Municipal São José, Joinville, SC, Brasil
| | | | - Henrique Ayzemberg
- Serviço de Residência Médica, Instituto de Ortopedia e Traumatologia de Joinville, Hospital Municipal São José, Joinville, SC, Brasil
| | - Valdir Steglich
- Serviço de Residência Médica, Instituto de Ortopedia e Traumatologia de Joinville, Hospital Municipal São José, Joinville, SC, Brasil
| | - Tiago Salati Stangarlin
- Serviço de Residência Médica, Instituto de Ortopedia e Traumatologia de Joinville, Hospital Municipal São José, Joinville, SC, Brasil
| |
Collapse
|
27
|
Kibar B. Combined palmar and dorsal plating of four-part distal radius fractures: Our clinical and radiological results. Jt Dis Relat Surg 2021; 32:59-66. [PMID: 33463419 PMCID: PMC8073437 DOI: 10.5606/ehc.2021.75599] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Accepted: 08/31/2020] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVES This study aims to investigate the radiological and clinical outcomes of four-part intraarticular distal radius fractures treated with a volar anatomically locked plate and 2 mm low-profile plates using both the volar and dorsal approaches. PATIENTS AND METHODS This retrospective study included 20 patients (8 males, 12 females; mean age 47±12.1; range, 25 to 67 years) who received open reduction and internal fixation with combined volar and dorsal plating to treat complex four-part distal radius fractures (shaft, radial styloid area, dorsal medial facet, volar medial facet) between May 2016 and January 2019. According to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, all fractures were 2R3-C3. According to Melone classification, one fracture was type 1, seven fractures were type 2a, three were type 2b, three were type 3 and six were type 4. The mean follow-up time was 21±7.5 (range, 12 to 36) months. RESULTS Union was achieved in all fractures. The mean tourniquet time was 103±12 (range, 90 to 130) minutes. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 10±9, and the mean Visual Analog Scale score was 2.1±0.9. According to Mayo wrist score, five patients had excellent, six had good, six had satisfactory and three had poor results. The mean grip strength was 25.2±9.2 (range, 15 to 40) kg and 78% of opposite side. Mean wrist flexion was 48.7°±15.3° (range, 30° to 80°), extension was 52.2°±17.2° (range, 25° to 80°), radio-ulnar deviation arc was 40.7°±6.9° (range, 30° to 55°), and mean forearm rotation arc was 152.3°±11° (range, 130° to 170°). CONCLUSION Plating method with a dual approach may be an alternative for four-part intraarticular distal radius fractures given its early mobility advantage and satisfactory functional and radiological results.
Collapse
Affiliation(s)
- Birkan Kibar
- Haydarpaşa Numune Eğitim ve Araştırma Hastanesi Ortopedi ve Travmatoloji Kliniği, 34668 Üsküdar, İstanbul, Türkiye.
| |
Collapse
|
28
|
Ilyas AM, Hayward GM, Harris JA, Wang W, Bucklen BS. Bridge Plate Design Effects on Yield and Fatigue in Distal Radius Fracture Model. J Wrist Surg 2020; 9:475-480. [PMID: 33282532 PMCID: PMC7708032 DOI: 10.1055/s-0040-1713419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 05/07/2020] [Indexed: 10/23/2022]
Abstract
Background Bridge plating for distal radius fractures is indicated for complex fractures with comminution, extensive articular involvement, and/or cases requiring immediate weight bearing. Bridge plate fixation of distal radius fractures is a well-documented treatment method; however, failures have been reported with repetitive loading through the bridged distal radius fracture. Plate design is implicated as a cause of plate fracture in select clinical studies but few mechanical tests comparing bridge plate designs have been reported. This study sought to determine the impact of plate design on bridge plates intended to allow for immediate weight-bearing. Methods Axial static ( n = 3) and dynamic testing ( n = 3) was performed on three distraction plates designs: bridge plate 1 (BP1) with central holes, bridge plate 2 (BP2) without central holes, and locking compression plate (BP3). Plates were loaded in axial compression with a simulated 10-mm fracture gap. Results Significant static load differences were noted between all groups. Static load to failure for BP1, BP3, and BP2 were 240 ± 5 N, 398 ± 9 N, and 420 ± 3 N, respectively ( p < 0.05). BP1 was the only plate series that failed during dynamic testing; all other plates achieved 100,000 cycles. Failure mode was a fracture occurring through the central screw hole of BP1. Finite element analysis demonstrated the effects of central screw holes on stress, strain, and plastic deformation under loading. Conclusion Unused screw holes are the mechanical weak points; plates designed without these central screw holes are expected to survive greater load values. The threshold for clinical importance will need to be determined by future studies.
Collapse
Affiliation(s)
- Asif M. Ilyas
- Department of Orthopaedic Surgery, Rothman Institute, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Gerald M. Hayward
- Musculoskeletal Education and Research Center (MERC), A Division of Globus Medical Inc., Audubon, Pennsylvania
| | - Jonathan A. Harris
- Musculoskeletal Education and Research Center (MERC), A Division of Globus Medical Inc., Audubon, Pennsylvania
| | - Wenhai Wang
- Musculoskeletal Education and Research Center (MERC), A Division of Globus Medical Inc., Audubon, Pennsylvania
| | - Brandon S. Bucklen
- Musculoskeletal Education and Research Center (MERC), A Division of Globus Medical Inc., Audubon, Pennsylvania
| |
Collapse
|
29
|
Role of a spanning plate as an internal fixator in complex distal radius fractures. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2020; 33:77-88. [PMID: 33245372 DOI: 10.1007/s00064-020-00686-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 06/11/2019] [Accepted: 07/19/2019] [Indexed: 10/22/2022]
Abstract
OBJECTIVE Minimally invasive temporary internal wrist arthrodesis as an alternative treatment method in complex distal radius fractures. INDICATIONS Complex distal radius fractures with dorsal and/or palmar comminution and little to no reconstruction possibilities, radiocarpal ligamentous injury, need for early weight bearing through the affected wrist (walking aids). CONTRAINDICATIONS Complex hand injuries limiting the possibility to safely secure the plate at either the metacarpal or the radial shaft. SURGICAL TECHNIQUE Percutaneous or open reduction and fixation of the distal radius fracture. Determine the location for the two stab incisions under fluoroscopy; one over the distal radial diaphysis and one over the second or third metacarpal. A third incision over Lister's tubercle allows transposition of the extensor pollicis longus (EPL) tendon, excision of the posterior interosseous nerve and dorsal arthrotomy. Retrograde insertion of the spanning plate. Placement of a first nonlocking screw through the glide hole into the metacarpal shaft. Under traction, a proximal screw hole is filled with a nonlocking screw into the radial diaphysis. Tightening of the cortical screws under lateral fluoroscopic view. The remaining screw holes at both the distal and proximal ends of the plate are filled with locking screws. Layered wound closure. POSTOPERATIVE MANAGEMENT A removable wrist splint is worn during 2 weeks. Weight bearing through the injured wrist is immediately allowed. Removal of the spanning plate is scheduled at 3 months after radiographic evidence of fracture consolidation. RESULTS In total, twelve distal radius fractures were treated by dorsal spanning plate fixation between January 2018 and January 2019. Average age was 53.3 ± 24.5 years (range 22-95 years). Both 3.5 mm and 2.4/2.7 mm plates were used. All twelve fractures were healed after 3 months. The mean Disabilities of Arm, Shoulder and Hand (DASH) score was 36.4 (range 8.3-70.0). There was one EPL tendon rupture, one case with extensor tendon adhesions, one periosteosynthetic fracture of the radial shaft and one complex regional pain syndrome. There was no implant failure and no infection.
Collapse
|
30
|
Meaike JJ, Kakar S. Management of Comminuted Distal Radius Fractures: A Critical Analysis Review. JBJS Rev 2020; 8:e2000010. [PMID: 32960024 DOI: 10.2106/jbjs.rvw.20.00010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Distal radius fractures occur in a bimodal age and sex distribution. Their incidence continues to rise with an increasingly active aging population. The current American Academy of Orthopaedic Surgeons guidelines for operative intervention are radial shortening of >3 mm, dorsal tilt of >10[degrees], or intra-articular displacement or step-off of >2 mm. The method of reduction and fixation should be selected on a case-by-case basis with a focus on patient factors, fracture behavior, surgical proficiency, and functional outcomes.
Collapse
Affiliation(s)
- Joshua J Meaike
- 1Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | |
Collapse
|
31
|
Rellán I, Nicholson LT, Ruch DS. Ulnohumeral Bridge Plating for Massive Distal Humerus Bone Loss: A Case Report. JBJS Case Connect 2020; 10:e0273. [PMID: 32224682 DOI: 10.2106/jbjs.cc.19.00273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE Massive bone loss around the elbow is a challenging clinical condition. Short periarticular osseous segments present few reconstructive options in the setting of distal humerus bone loss. We report the case of a 20-year-old man who sustained an open, intra-articular distal humerus fracture with a massive metaphyseal defect of 15 cm after a motorcycle accident. The defect was reconstructed using an induced membrane technique with temporary ulnohumeral bridge plate stabilization. CONCLUSION Temporary ulnohumeral spanning plate fixation is a reliable method for periarticular reconstruction in the setting of massive distal humerus bone loss.
Collapse
Affiliation(s)
- Ignacio Rellán
- Department of Orthopaedics, Italian Hospital of Buenos Aires, Buenos Aires, Argentina
| | - Luke Thomas Nicholson
- Clinical Orthopaedic Surgery, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - David S Ruch
- Department of Orthopaedic Surgery, Division of Hand, Upper Extremity, and Microvascular Surgery, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
32
|
Wang WL, Ilyas AM. Dorsal Bridge Plating versus External Fixation for Distal Radius Fractures. J Wrist Surg 2020; 9:177-184. [PMID: 32257622 PMCID: PMC7113002 DOI: 10.1055/s-0039-1694063] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Accepted: 06/25/2019] [Indexed: 10/26/2022]
Abstract
Background External fixation and dorsal bridge plating are wrist spanning fixation options for distal radius fractures; however, their comparative effectiveness is not well understood. A meta-analysis was conducted to compare the clinical outcomes between these two techniques. Materials and Methods A PubMed database query of all distal radius fracture cases managed with spanning external fixation or dorsal bridge plating was performed. A total of 28 articles met inclusion criteria, yielding 895 patients for data extraction and comparative analysis. Results Dorsal bridge plating demonstrated lower rates of infection (2 vs. 10%, p = 0.05) and complex regional pain syndrome (1 vs. 4%, p = 0.04) but higher rates of hardware failure (4 vs. 1%, p = 0.026). Bridge plating also demonstrated higher rates of excellent/good ratings under the Gartland and Werley outcome score (91 vs. 83%, p = 0.016). There was no significant difference in DASH (Disability of the Arm, Shoulder, and Wrist) scores, radiographic parameters, or unplanned reoperations between the two spanning fixation options. Conclusion Bridge plating and external fixation both appear to be comparable for spanning fixation constructs for distal radius fractures, but with bridge plating having a potentially lower complication profile.
Collapse
Affiliation(s)
- William L. Wang
- Department of Orthopaedic Surgery, Thomas Jefferson University and the Rothman Institute, Philadelphia, Pennsylvania
| | - Asif M. Ilyas
- Department of Orthopaedic Surgery, Thomas Jefferson University and the Rothman Institute, Philadelphia, Pennsylvania
| |
Collapse
|
33
|
Guerrero EM, Lauder A, Federer AE, Glisson R, Richard MJ, Ruch DS. Metacarpal Position and Lunate Facet Screw Fixation in Dorsal Wrist-Spanning Bridge Plates for Intra-Articular Distal Radial Fracture: A Biomechanical Analysis. J Bone Joint Surg Am 2020; 102:397-403. [PMID: 31904607 DOI: 10.2106/jbjs.19.00769] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND A dorsal wrist-spanning plate (DWSP) can be affixed to the second or third metacarpal, depending on the morphology of the distal radial fracture (DRF) and on surgeon preference, but comparative biomechanical analyses between these methods are limited. This biomechanical study compared fixation to the second metacarpal versus the third metacarpal as measured by lunate facet fragment displacement in a cadaveric model of an axially loaded intra-articular DRF. The construct rigidity with the addition of an intrafragmentary lunate facet locking screw was also evaluated. METHODS A sample size of 14 cadaveric matched pairs was calculated to achieve 81.7% power. The 28 limbs were randomized to DWSP fixation to the second metacarpal (Group 1) or third metacarpal (Group 2); each wrist underwent an osteotomy simulating an unstable intra-articular DRF. Limbs were tested at axial loads of 50, 100, 150, 200, 250, and 300 N. Lunate facet displacement from the metaphyseal fragment at each load was measured with use of differential variable reluctance transducers. After initial testing, a locking screw was placed through the plate into the lunate facet fragment in the third metacarpal group (Group 3). Displacement measurements were repeated for all loads. Paired 2-tailed t tests with Bonferroni correction (significance, p < 0.008) were performed to assess differences in fragment stability between groups. RESULTS The average fracture displacement at 300 N was 0.8 mm in Group 1, 0.4 mm in Group 2, and 0.2 mm in Group 3. Plating to the third metacarpal more effectively resisted displacement compared with the second metacarpal at all axial loads (p < 0.008). The addition of a lunate facet screw further stiffened the construct at loads of ≥200 N (p < 0.008). CONCLUSIONS Plate fixation to the third metacarpal with an intrafragmentary screw was the most biomechanically favorable construct, although other factors may favor an alternative distal fixation site. Mean displacement of the lunate facet fragment at 300 N was <1 mm in all groups. CLINICAL RELEVANCE The present study demonstrated that a DWSP affixed to the third metacarpal with an intrafragmentary screw provides the most effective stabilization of the lunate facet fragment in intra-articular DRFs. This study validates the use of intrafragmentary screws to increase stability in DWSP fixation.
Collapse
Affiliation(s)
- Evan M Guerrero
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Alexander Lauder
- Department of Orthopaedic Surgery, Denver Health Medical Center, Denver, Colorado
| | - Andrew E Federer
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Richard Glisson
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Marc J Richard
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - David S Ruch
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
34
|
Vakhshori V, Alluri RK, Stevanovic M, Ghiassi A. Review of Internal Radiocarpal Distraction Plating for Distal Radius Fracture Fixation. Hand (N Y) 2020; 15:116-124. [PMID: 30003802 PMCID: PMC6966280 DOI: 10.1177/1558944718787877] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Internal radiocarpal distraction plating is a versatile tool in the treatment of distal radius fractures that are not amenable to nonoperative treatment or operative fixation with standard volar or dorsal implants. Internal distraction plates may also be indicated in the setting of polytrauma or osteopenic bone. The plate functions as an internal fixator, using ligamentotaxis to restore length and alignment while providing relative stability for bony healing. The plate can be fixed to either the second or the third metacarpal, and anatomic and biomechanical studies have assessed the strengths and weaknesses of each strategy. This operative fixation technique leads to acceptable radiographic results and functional outcomes. Following fracture union, the plate is removed, and wrist range of motion is resumed.
Collapse
Affiliation(s)
- Venus Vakhshori
- Keck Medical Center at the University of
Southern California, Los Angeles, USA
| | - Ram Kiran Alluri
- Keck Medical Center at the University of
Southern California, Los Angeles, USA,Ram Kiran Alluri, Department of Orthopaedic
Surgery, Keck Medical Center at the University of Southern California, 1520 San
Pablo Street, #2000, Los Angeles, CA 90033, USA.
| | - Milan Stevanovic
- Keck Medical Center at the University of
Southern California, Los Angeles, USA
| | - Alidad Ghiassi
- Keck Medical Center at the University of
Southern California, Los Angeles, USA
| |
Collapse
|
35
|
Sharareh B, Mitchell S. Radiographic Outcomes of Dorsal Spanning Plate for Treatment of Comminuted Distal Radius Fractures in Non-Elderly Patients. JOURNAL OF HAND SURGERY GLOBAL ONLINE 2019; 2:94-101. [PMID: 35415482 PMCID: PMC8991644 DOI: 10.1016/j.jhsg.2019.10.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 10/03/2019] [Indexed: 11/29/2022] Open
Abstract
Purpose Multifragmentary fractures of the distal radius with articular and metaphyseal comminution (AO 23-C3) represent challenging injuries to manage. Distal fracture lines, articular comminution, and limited distal bone stock may preclude stable fixation with a volar locking plate. The use of a dorsal spanning plate (DSP) offers an alternative treatment option in this setting. We examined the radiographic outcomes of a consecutive series of patients with comminuted intra-articular distal radius fractures not amenable to volar locked plating, who were treated with a DSP. Methods We reviewed all distal radius fractures treated with a dorsal spanning plate at our institution between October, 2014 and March, 2018. Patients with AO 23-C3 fractures treated with dorsal spanning plate fixation were included in this study. Demographic data, time from plate placement to removal, and postoperative radiographic outcomes were examined. Results We identified 24 patients, mean age 41 years (range, 19-62 years). Mean follow-up was 19.5 weeks (range, 12-35 weeks) from the time of plate placement. Plates were removed at a mean of 87 days (range, 40-215 days) after surgery. All patients achieved radiographic union. Mean radial height at the time of union was 11.1 mm (SD, ±3.7 mm; range, 6-18 mm), radial inclination was 19.7° (SD, ±5.4°; range, 9° to 30°), ulnar variance was 1.0 mm (SD, ±2.4 mm; range, -3 to 6 mm), and volar tilt was 1.4° (SD, ±5.2°; range, -10° to 14°). Mean articular displacement was 1.7 mm (SD, ±1.7 mm; range, 0-6 mm). Malalignment of at least one of these radiographic parameters was identified in 16 of 24 patients at the time of union. Conclusions Dorsal spanning plate fixation offers an alternative treatment option for comminuted intra-articular distal radius fractures (AO 23-C3). Although this technique presents a straightforward means for fixation of complex distal radius fractures, radiographic outcomes may be inferior relative to less complex fractures treated with standard volar plating techniques. Type of study/level of evidence Therapeutic IV.
Collapse
Affiliation(s)
- Behnam Sharareh
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, TX
| | - Scott Mitchell
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, TX
| |
Collapse
|
36
|
Hyatt BT, Hanel DP, Saucedo JM. Bridge Plating for Distal Radius Fractures in Low-Demand Patients With Assist Devices. J Hand Surg Am 2019; 44:507-513. [PMID: 30366732 DOI: 10.1016/j.jhsa.2018.08.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 08/13/2018] [Accepted: 08/27/2018] [Indexed: 02/02/2023]
Abstract
Bridge plate fixation has traditionally been described for the treatment of high-energy distal radius fractures with extensive comminution, associated instability, and polytrauma with the need for immediate upper extremity assisted weight bearing. Certain patient populations who may similarly benefit from such effective and expedient stabilization include patients with multiple comorbidities who may have lower-energy fractures, poor bone quality, and a baseline reliance on ambulatory assist devices. This article reviews treatment considerations for distal radius fractures in low-demand patients and explores the rationale and technique of bridge plate fixation in this population.
Collapse
Affiliation(s)
- Brad T Hyatt
- Department of Orthopaedics, Wright-Patterson Medical Center, Dayton, OH
| | - Douglas P Hanel
- Department of Orthopedics and Sports Medicine, University of Washington Medical Center, Seattle, WA
| | - James M Saucedo
- The Hand Center of San Antonio, UT Health San Antonio Department of Orthopaedics, San Antonio, TX.
| |
Collapse
|
37
|
Perlus R, Doyon J, Henry P. The use of dorsal distraction plating for severely comminuted distal radius fractures: A review and comparison to volar plate fixation. Injury 2019; 50 Suppl 1:S50-S55. [PMID: 31040029 DOI: 10.1016/j.injury.2019.03.052] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 03/28/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Optimal fixation for highly comminuted distal radius fractures remains a major treatment challenge for orthopaedic surgeons. Dorsal distraction plating can serve as an improved fixation technique by allowing reduction under ligamentotaxis, providing a dorsal buttress, addressing proximal comminution, and allowing for early weightbearing in polytrauma patients. The aim of this study was to review current literature regarding treatment of distal radius fractures treated with dorsal distraction plating. METHODS We performed a literature search in Pubmed and EMBASE databases to identify all studies analyzing use of dorsal distraction plating. Case reports, biomechanical and anatomic cadaver studies were excluded from analysis. Primary outcome measures were range of motion (ROM) at final follow up, grip strength, and radiographic parameters. RESULTS Eight studies were included in the final analysis. Pooled mean ROM after dorsal distraction plating was found to be 47.6° of flexion, 50.5° of extension, 76.0° of pronation, and 74.2° of supination. Pooled mean grip strength was 79.1% compared to the uninjured contralateral limb. Pooled mean volar tilt was 3.6°. Overall radial height was maintained at an average of 10.5 mm with a pooled mean loss of only 3.8 mm in length. Mean radial inclination was found to be 19.4 mm with patients having a mean ulnar variance of 0.5 mm. DISCUSSION & CONCLUSION Treatment of comminuted intra-articular distal radius fractures with dorsal distraction plating yielded excellent outcomes with very low complication rates, and has several advantages over volar plating and/or external fixation for these fractures. Necessity of plate removal remains a negative feature of this technique.
Collapse
Affiliation(s)
- R Perlus
- University of Toronto, Department of Orthopaedic Surgery, Toronto, ON, Canada.
| | - J Doyon
- University of Toronto, Department of Orthopaedic Surgery, Toronto, ON, Canada
| | - P Henry
- Sunnybrook Health Sciences Center, Holland Orthopaedic and Arthritic Center, Toronto, ON, Canada
| |
Collapse
|
38
|
Azad A, Intravia JM, Hill JR, Leland H, Vakhshori V, Stevanovic M, Ghiassi A. Carpal Translocation Following Dorsal Bridge Plate Fixation of Distal Radius Fractures: A Cadaveric Study. J Wrist Surg 2019; 8:234-239. [PMID: 31192046 PMCID: PMC6546489 DOI: 10.1055/s-0039-1683434] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 01/28/2019] [Indexed: 01/26/2023]
Abstract
Background Dorsal bridge plate fixation is an effective technique for stabilization of highly comminuted, complex distal radius fractures. However, it is unknown whether fixation to the second or third metacarpal is optimal. Given dorsal bridge plating spans the radiocarpal joint, it is unclear if the dorsal spanning plate affects carpal position. This study investigates differences in carpal translocation resulting from bridge plate distal fixation to either the second or third metacarpal. Methods Ten paired cadaveric upper extremities without evidence of gross deformity or prior surgery distal to the elbow were evaluated with three-view wrist fluoroscopic images for baseline radiographic measurements. An unstable distal radius fracture model was created via a volar approach using a 1-cm osteotomy. Following fracture creation, a dorsal bridge plate was applied with random to the second metacarpal on one limb, and the third metacarpal on the contralateral limb. Laterality for distal fixation was chosen randomly. Fluoroscopic images were repeated and radial inclination, radial height, radiocarpal angle, volar tilt, ulnar variance, radiolunate angle, radioscaphoid angle, radial rotation index, and carpal translocation were measured. Results Radial inclination, radial height, radiocarpal angle, volar tilt, ulnar variance, radiolunate angle, and radioscaphoid angle were not statistically different before and after fixation, or when comparing the second or third metacarpal fixation. Additionally, there was no difference in Taleisnik's ulnar translocation index, Chamay's ulnar translation index, or McMurtry's carpal translation index based on which metacarpal was used for distal fixation. Conclusions Dorsal bridge plate fixation of distal radius fractures restores preoperative physiologic measures of the radius, ulna, and carpus. Carpal translocation was similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a bridge plate. Level of Evidence This is a Level V, therapeutic study.
Collapse
Affiliation(s)
- Ali Azad
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| | - Jessica M. Intravia
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| | - J. Ryan Hill
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| | - Hyuma Leland
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| | - Venus Vakhshori
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| | - Milan Stevanovic
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| | - Alidad Ghiassi
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, California
| |
Collapse
|
39
|
Lauder A, Hanel DP. Spanning Bridge Plate Fixation of Distal Radial Fractures. JBJS Rev 2019; 5:01874474-201702000-00002. [PMID: 28248738 DOI: 10.2106/jbjs.rvw.16.00044] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Alexander Lauder
- Department of Orthopaedics, University of Washington, Seattle, Washington
| | | |
Collapse
|
40
|
Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review. Case Rep Orthop 2018; 2018:3256891. [PMID: 30510827 PMCID: PMC6231376 DOI: 10.1155/2018/3256891] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 10/02/2018] [Indexed: 11/18/2022] Open
Abstract
Background Dorsal spanning plate fixation is an increasingly popular method of fixation for certain distal radius fractures. Published outcomes are encouraging, but complications are still reported. Methods We present a case report of a 26-year-old woman with spanning plate breakage and extensor pollicis longus (EPL) metallosis, fraying, and near-complete rupture. The patient's unsuccessful follow-up led to this complication. Metallosis and damage to the extensor indices (EI) and distal extensor carpi radialis longus (ECRL) were intraoperative obstacles for tendon transfer to restore EPL function. Results Tendon transfer in the setting of bridge plate failure has not yet been described in the literature. There are reports of spanning plate failure indicating that breakage often happens through the plate's holes and after fracture healing. Conclusions The compounded complication of plate failure with extensor tendon injury emphasizes the important relationship between the local anatomy, barriers to patient care, and potential problems after spanning plate fixation.
Collapse
|
41
|
Herzberg G, Walch A, Burnier M. Wrist hemiarthroplasty for irreparable DRF in the elderly. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 28:1499-1503. [PMID: 29796826 DOI: 10.1007/s00590-018-2228-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 05/19/2018] [Indexed: 12/17/2022]
Abstract
INTRODUCTION The authors update their results of wrist hemiarthroplasty for irreparable distal radius fracture in the elderly, at a minimum of 2-year follow-up. MATERIALS AND METHODS Between 2011 and 2018, 25 consecutive independent elderly patients (24 female, 27 wrists) were treated with wrist hemiarthroplasty for distal radius fracture at a single institution. The average age was 77 years (range 65-88). They all were independent at home. A total of 19 wrists were treated at the acute stage, and 8 secondary procedures. The average follow-up was 32 months (range 24-44). RESULTS There was no dislocation, loosening, infection nor removal of the implants. We observed 3 CRPS. At final follow-up, the average VAS pain was 1/10, mean forearm pronation/supination arc was 150°, and mean active flexion-extension arc was 60°. Average wrist extension was 36°. Mean grip strength was 68% of contralateral side. Mean Lyon wrist score was 74%. Mean Quick DASH score was 26%, and mean PRWE score was 25%. DISCUSSION Our data suggest that treatment of acute irreparable distal radius fracture in the independent elderly patient with a bone-preserving primary wrist hemiarthroplasty may be a viable option. Longer-term follow-up are needed to confirm these preliminary data.
Collapse
Affiliation(s)
- Guillaume Herzberg
- Service de Chirurgie Orthopédique Membre Supérieur, Hôpital Edouard Herriot, CHU Lyon, 5 Place d'Arsonval, 69003, Lyon, France.
| | - Arnaud Walch
- Service de Chirurgie Orthopédique Membre Supérieur, Hôpital Edouard Herriot, CHU Lyon, 5 Place d'Arsonval, 69003, Lyon, France
| | - Marion Burnier
- Service de Chirurgie Orthopédique Membre Supérieur, Hôpital Edouard Herriot, CHU Lyon, 5 Place d'Arsonval, 69003, Lyon, France
| |
Collapse
|
42
|
Huish EG, Coury JG, Ibrahim MA, Trzeciak MA. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction. Hand (N Y) 2018; 13:346-349. [PMID: 28403633 PMCID: PMC5987982 DOI: 10.1177/1558944717704514] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background: The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Methods: Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. Results: All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Conclusions: Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.
Collapse
Affiliation(s)
- Eric G. Huish
- Valley Orthopedic Surgery Residency, Modesto, CA, USA
- Eric G. Huish Jr, Valley Orthopedic Surgery Residency, 1441 Florida Avenue, Modesto, CA 95350, USA.
| | - John G. Coury
- Valley Orthopedic Surgery Residency, Modesto, CA, USA
| | | | | |
Collapse
|
43
|
Huang JI, Peterson B, Bellevue K, Lee N, Smith S, Herfat S. Biomechanical Assessment of the Dorsal Spanning Bridge Plate in Distal Radius Fracture Fixation: Implications for Immediate Weight-Bearing. Hand (N Y) 2018; 13:336-340. [PMID: 28387161 PMCID: PMC5987984 DOI: 10.1177/1558944717701235] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The goal of this study was to compare the biomechanical stability of a 2.4-mm dorsal spanning bridge plate with a volar locking plate (VLP) in a distal radius fracture model, during simulated crutch weight-bearing. METHODS Five paired cadaveric forearms were tested. A 1-cm dorsal wedge osteotomy was created to simulate an unstable distal radius fracture with dorsal comminution. Fractures were fixed with a VLP or a dorsal bridge plate (DBP). Specimens were mounted to a crutch handle, and optical motion-tracking sensors were attached to the proximal and distal segments. Specimens were loaded in compression at 1 mm/s on a servohydraulic test frame until failure, defined as 2 mm of gap site displacement. RESULTS The VLP construct was significantly more stable to axial load in a crutch weight-bearing model compared with the DBP plate (VLP: 493 N vs DBP: 332 N). Stiffness was higher in the VLP constructs, but this was not statistically significant (VLP: 51.4 N/mm vs DBP: 32.4 N/mm). With the crutch weight-bearing model, DBP failed consistently with wrist flexion and plate bending, whereas VLP failed with axial compression at the fracture site and dorsal collapse. CONCLUSIONS Dorsal spanning bridge plating is effective as an internal spanning fixator in treating highly comminuted intra-articular distal radius fracture and prevents axial collapse at the radiocarpal joint. However, bridge plating may not offer advantages in early weight-bearing or transfer in polytrauma patients, with less axial stability in our crutch weight-bearing model compared with volar plating. A stiffer 3.5-mm DBP or use of a DBP construct without the central holes may be considered for distal radius fractures if the goal is early crutch weight-bearing through the injured extremity.
Collapse
Affiliation(s)
- Jerry I. Huang
- Department of Orthopaedics and Sports Medicine, University of Washington Medical Center, Seattle, USA,Jerry I. Huang, Associate Professor, Department of Orthopaedics and Sports Medicine, University of Washington Medical Center, 4245 Roosevelt Way NE, Box 354740, Seattle, WA 98105, USA.
| | - Bret Peterson
- Department of Orthopaedics and Sports Medicine, University of Washington Medical Center, Seattle, USA
| | - Kate Bellevue
- Department of Orthopaedics and Sports Medicine, University of Washington Medical Center, Seattle, USA
| | - Nicolas Lee
- Department of Orthopaedic Surgery, University of California, San Francisco, USA
| | - Sean Smith
- Department of Orthopaedic Surgery, University of California, San Francisco, USA
| | - Safa Herfat
- Department of Orthopaedic Surgery, University of California, San Francisco, USA
| |
Collapse
|
44
|
Tinsley BA, Ilyas AM. Distal Radius Fractures in a Functional Quadruped: Spanning Bridge Plate Fixation of the Wrist. Hand Clin 2018; 34:113-120. [PMID: 29169592 DOI: 10.1016/j.hcl.2017.09.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Patients who require assistive devices with their hands for mobilization are called functional quadrupeds. These patients pose a unique challenge after they have a distal radius fracture, as their injury not only limits the wrist but also compromises ambulation. The authors propose a different treatment strategy for functional quadrupeds to improve mobilization and weight-bearing with the injured limb after a distal radius fracture. In this article, the authors define the functional quadruped and describe their technique of spanning bridge plate fixation with a retrospective review of patient outcomes.
Collapse
Affiliation(s)
- Brian A Tinsley
- Rothman Institute at Thomas Jefferson University, 925 Chestnut Street, Philadelphia, PA 19107, USA
| | - Asif M Ilyas
- Rothman Institute at Thomas Jefferson University, 925 Chestnut Street, Philadelphia, PA 19107, USA.
| |
Collapse
|
45
|
Alluri RK, Bougioukli S, Stevanovic M, Ghiassi A. A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model. J Hand Surg Am 2017; 42:748.e1-748.e8. [PMID: 28601513 DOI: 10.1016/j.jhsa.2017.05.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 05/04/2017] [Accepted: 05/12/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. METHODS Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. RESULTS Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. CONCLUSIONS Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. CLINICAL RELEVANCE The treating surgeon should choose distal metacarpal fixation primarily based on fracture pattern, alignment, and soft tissue integrity. If a stiffer construct is desired, placement of the radiocarpal spanning plate at the third metacarpal is preferred.
Collapse
Affiliation(s)
- Ram K Alluri
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, CA.
| | - Sofia Bougioukli
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, CA
| | - Milan Stevanovic
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, CA
| | - Alidad Ghiassi
- Department of Orthopaedic Surgery, Keck Medical Center of University of Southern California, Los Angeles, CA
| |
Collapse
|
46
|
Xu M, Xiang F, Li C, Xiaohereti S, Sheng J. [Surgical techniques and effectiveness of volar locking plates for senile delayed distal radius fractures]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2017; 31:785-789. [PMID: 29845802 DOI: 10.7507/1002-1892.201702039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To investigate the surgical technique and effectiveness of volar locking plates for senile delayed distal radius fractures. Methods Between October 2014 and September 2015, 25 cases of delayed distal radius fractures were treated by volar locking plates. There were 3 males and 22 females with an average age of 73 years (range, 65-87 years). Injury was caused by tumble in 19 cases and by traffic accident in 6 cases. All the cases had closed fracture. According to the AO classification, 10 cases were rated as type A2, 7 cases as type A3, 3 cases as type B3, and 5 cases as type C1. The manual reduction and plaster immobilization were performed in 18 cases first, but reduction failed; no treatment was given in 7 cases before surgery. The time from injury to surgery was from 33 to 126 days (mean, 61 days). Preoperatively, the volar tilting angle was (-16.0±3.1)°; the ulnar inclining angle was (10.8±7.0)°; the radial shortening was (11.2±3.6) mm; the wrist range of motion was (41.0±7.5)° in flexion and was (42.0±6.3)° in extension; and the grip strength was 33.0%±3.1% of normal side. Results All incisions healed primarily, and no postoperative complication occurred. The patients were followed up 1-1.5 years (mean, 1.3 years). The X-ray films showed that fracture union was achieved in all the patients, with the mean healing time of 9.2 weeks (range, 8-12 weeks); the displacement of the articular surface was less than 1 mm. At last follow-up, the volar tilting angle was (13.1±3.2)°; the ulnar inclining angle was (21.9±4.6)°; the radial shortening was (2.0±1.1) mm; the wrist range of motion was (52.0±11.7)° in flexion and was (65.0±4.8)° in extension; and the grip strength was 84.0%±4.2% of normal side; all showed significant difference when compared with preoperative ones ( P<0.05). According to the Gartland and Werley score, the results were excellent in 15 cases, good in 6 cases, fair in 2 cases, and poor in 2 cases at last follow-up; the excellent and good rate was 84%. Conclusion By the good design of the volar locking plate and the command of surgical techniques, good effectiveness can be achieved in the treatment of senile delayed distal radius fracture.
Collapse
Affiliation(s)
- Mingjian Xu
- Department of Orthopedics, Sixth Affiliated Hospital of Shanghai Jiao Tong University, Shanghai, 200233, P.R.China
| | - Fuzhou Xiang
- Department of Orthopedics, Sixth Affiliated Hospital of Shanghai Jiao Tong University, Shanghai, 200233, P.R.China
| | - Chunxiao Li
- Department of Orthopedics, Sixth Affiliated Hospital of Shanghai Jiao Tong University, Shanghai, 200233, P.R.China
| | - Sulaiti Xiaohereti
- Department of Orthopedics, Sixth Affiliated Hospital of Shanghai Jiao Tong University, Shanghai, 200233, P.R.China
| | - Jiagen Sheng
- Department of Orthopedics, Sixth Affiliated Hospital of Shanghai Jiao Tong University, Shanghai, 200233,
| |
Collapse
|
47
|
Wigton MD, Nazir OF, Graves BR, Apel PJ, Li Z. Dorsal Distraction Plating and Lunate Decortication for Stage III Kienböck Disease: A Novel Technique. Tech Hand Up Extrem Surg 2017; 21:13-17. [PMID: 27984361 DOI: 10.1097/bth.0000000000000146] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Kienböck disease (KD) is a progressive condition and difficult to manage. A number of treatment algorithms exist but there is no clear consensus as to which method produces the best outcome, particularly for Lichtman stage III disease. The majority of the current treatment options for KD emphasize lunate unloading and restoration of biology with bone graft. However, less attention has been given to the protection of the lunate during revascularization process. We report a novel technique of lunate decompression and bone grafting, combined with wrist distraction with or without radial shortening osteotomy via dorsal wrist bridge plating for the treatment of stage II-IIIa/b KD. This technique provides the advantages of distraction of the carpus unloading the lunate after bone grafting and during revascularization without the issues inherent to external fixation. In addition, this technique allows compression through a radial osteotomy site when performed. Our approach to the treatment of KD has incorporated this technique for patients with stage II or IIIa/b disease.
Collapse
Affiliation(s)
- Michael D Wigton
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Medical Center Boulevard, Winston Salem, NC
| | | | | | | | | |
Collapse
|
48
|
Abstract
Distal radius fractures are common in elderly patients, and the incidence continues to increase as the population ages. The goal of treatment is to provide a painless extremity with good function. In surgical decision making, special attention should be given to the patient's bone quality and functional activity level. Most of these fractures can be treated nonsurgically, and careful closed reduction should aim for maintenance of anatomic alignment with a focus on protecting fragile soft tissues. Locked plating is typically used for fracture management when surgical fixation is appropriate. Surgical treatment improves alignment, but improvement in radiographic parameters may not lead to better clinical outcomes. Treatment principles, strategies, and clinical outcomes vary for these injuries, with elderly patients warranting special consideration.
Collapse
|
49
|
Jain MJ, Mavani KJ. A Comprehensive Study of Internal Distraction Plating, an Alternative Method for Distal Radius Fractures. J Clin Diagn Res 2016; 10:RC14-RC17. [PMID: 28208956 DOI: 10.7860/jcdr/2016/21926.9036] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Accepted: 10/01/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION The management of highly comminuted distal radius fractures still remains a major treatment challenge. Articular comminution and compromised bone quality are the culprits. One novel approach is the technique of Internal Distraction Plating which involves "bridging" the fracture with the use of a standard 3.5mm plate applied dorsally in distraction from the radius, proximal to the fracture, to the long finger metacarpal distally, bypassing the comminuted segment. The plate is removed once fracture union has been achieved. AIM The present study was conducted with the aim to evaluate the role of internal dorsal distraction plating as an alternative method in the treatment of fracture distal radius in terms of special indications, technique and outcome. MATERIALS AND METHODS This study was a prospective longitudinal study on 20 patients (mean age 62 years) treated with internal distraction plating for comminuted distal radius fractures with specific indications. Regular follow-ups with standard radiographs and analysis were done upto 24 months. Functional outcome were assessed by DASH Score and the Gartland and Werley demerit score. RESULTS At final follow-up, all fractures had united and X-rays showed mean palmar tilt of 7°, positive ulnar variance of 0.5mm, radial inclination of 18° and average loss of 2mm of radial height. Mean range of motion values for wrist flexion 46°, extension 50°, pronation 79° and supination 77° At final follow-up, the mean DASH score was 32. 85% patient had excellent to good result as per Gartland and Werley demerit score. This construct has yield satisfactory clinical and radiographic results with these very challenging injuries. CONCLUSION The purpose of this study was to report the radiographic and the functional outcomes of treatment with this technique. External fixator and volar plating in communited distal end radius fractures are not always satisfactory in old age with osteoporotic bone because of complications associated with them. The current technique represents an alternative that provides union of the comminuted distal radius fracture with anatomical alignment, optimal range of motion and with minimal clinical disability.
Collapse
Affiliation(s)
- Mohit J Jain
- Assistant Professor and Consultant Trauma Surgeon, Department of Orthopaedics, Sanjeevani Multispeciality Hospital , Jetpur, District-Rajkot Gujarat, India
| | - Kinjal J Mavani
- Senior Resident and Lecturer, Department of Orthodontics, Maratha Mandal Institute , Belgaum, Karnataka, India
| |
Collapse
|
50
|
Herzberg G, Burnier M. [What is the role of primary or secondary hemiarthroplasty for distal radius fractures in independent elderly patients?]. HAND SURGERY & REHABILITATION 2016; 35S:S137-S140. [PMID: 27890199 DOI: 10.1016/j.hansur.2016.03.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Revised: 03/07/2016] [Accepted: 03/29/2016] [Indexed: 11/17/2022]
Abstract
The authors report their experience with wrist hemiarthroplasty for acute irreparable distal radius fractures in independent elderly patients (12 women, mean age 76years) and following failed initial treatment in the same population (5 women, mean age 75years). The first 11 cases have a mean follow-up of 30months. No complications requiring implant removal were reported. At follow-up, the mean VAS for pain was 1/10, the mean flexion-extension arc was 60°, the Lyon Wrist score was 73 % and the PRWE (Patient-Related Wrist Evaluation) was 22 points. The five patients who had secondary procedures and were reviewed at mean of 16months' follow-up did not require implant removal but there was one complete forearm rotational ankylosis with ossification. At follow-up, the mean VAS for pain was 3/10, the mean flexion-extension arc was 56°, the Lyon Wrist score was 65 % and the PRWE was 45 points. The authors believe that hemiarthroplasty is a useful salvage procedure for irreparable wrist fractures in the emergency room and after failed initial treatment in active elderly patients.
Collapse
Affiliation(s)
- G Herzberg
- Service de chirurgie orthopédique main, membre supérieur, hôpital Édouard-Herriot, place d'Arsonval, 69437 Lyon cedex 03, France.
| | - M Burnier
- Service de chirurgie orthopédique main, membre supérieur, hôpital Édouard-Herriot, place d'Arsonval, 69437 Lyon cedex 03, France
| |
Collapse
|