Table 1 Distinction among multimodal artificial intelligence concepts in gastrointestinal endoscopy
| Concept | Direct model input | Key distinction | Typical outputs | Key limitations |
| Multimodal learning | ≥ 2 heterogeneous data sources | Broad fusion/alignment paradigm; not a specific architecture | Prediction, cross-modal representation, decision support, structured output | Missing and asynchronous data |
| VLM | Image/video + text | Learns visual–language representations or alignment | Image-text alignment, retrieval, annotation, visual description | Weak temporal modeling and limited grounding |
| MLLM | Visual + text + multimodal input | LLM-centered generation conditioned on visual input | Visual question answering, draft report generation | Hallucination and long-video challenges |
| Text-based LLM | Text | No direct access to endoscopic visual input | Summarization, information extraction, patient communication | Inability to directly interpret images |
Table 2 Representative clinical and diagnostic-validation studies of artificial intelligence across gastrointestinal endoscopy tasks and workflows
| Ref. | Region/setting | Population/sample size | AI function | Study design/comparator | Evaluation unit | Key findings | Validation/main limitation |
| Wang et al[7], 2019 | China; colonoscopy | 1058 patients; 522 CADe, 536 control | Real-time CADe | Prospective randomized trial; CADe vs standard colonoscopy | Patient | ADR: 29.1% vs 20.3%; adenomas/patient: 0.53 vs 0.31 | Single-center, non-blinded trial; benefit mainly driven by diminutive adenomas |
| Byrne et al[8], 2019 | Colonoscopy video | 125 diminutive-polyp videos; 106 analyzed | CADx for adenoma vs hyperplastic polyp | Independent video test set; histopathology reference | Lesion/video | Sensitivity: 98%; specificity: 83%; accuracy: 94%; NPV: 97% | Offline video evaluation; 19/125 lesions lacked sufficient prediction confidence; no live clinical trial |
| Wu et al[9], 2019 | China; EGD | 324 randomized; 303 analyzed | WISENSE blind-spot monitoring | RCT; WISENSE-assisted vs conventional EGD | Patient/procedure | Blind spot rate: 5.86% vs 22.46%, P < 0.001 | Single-center trial; procedure-quality endpoint |
| Gong et al[23], 2020 | China; colonoscopy | 704 randomized; 355 ENDOANGEL, 349 control | Real-time CADe/withdrawal-quality support | Randomized trial; ENDOANGEL vs unassisted colonoscopy | Patient | ADR: 16% vs 8%; odds ratio: 2.3, P = 0.001 | Single-center study; relatively low baseline ADR |
| Wang et al[24], 2020 | China; colonoscopy | 1010 randomized; 962 analyzed | Real-time CADe | Double-blind randomized trial; CADe vs sham system | Patient | ADR: 34% vs 28%; odds ratio: 1.36, P = 0.03 | Single-center; interval-CRC benefit not evaluated |
| Repici et al[25], 2020 | Italy; colonoscopy | 685 participants; 341 CADe, 344 control | GI Genius CADe | Multicenter randomized trial; CADe vs standard colonoscopy | Patient/procedure | ADR: 54.8% vs 40.4%; APC: 1.07 vs 0.71 | Multicenter clinical evidence; no long-term cancer-outcome assessment |
| Shaukat et al[26], 2022 | United States; screening/surveillance colonoscopy | 1359 analyzed; 682 CADe, 677 standard | SKOUT CADe | Multicenter randomized trial; CADe vs standard colonoscopy | Patient/procedure | ADR: 47.8% vs 43.9%, P = 0.065; APC: 1.05 vs 0.83, P = 0.002 | Multicenter United States evidence; ADR difference not statistically significant |
| Spada et al[36], 2024 | 14 European centers; small-bowel CE | 137 enrolled; 133 analyzed | AI-assisted capsule reading | Prospective multicenter paired comparison; AI-assisted vs standard reading | Patient | Diagnostic yield: 73.7% vs 62.4%; reading time: 3.8 minutes vs 33.7 minutes | Strong workflow benefit; downstream management and clinical outcomes not evaluated |
| Seager et al[27], 2024 | United Kingdom; 12 NHS hospitals | 2032 randomized | GI Genius CADe | Pragmatic multicenter RCT; CADe vs standard colonoscopy | Patient/procedure | Adenomas/procedure: 1.56 vs 1.21; ADR: 56.6% vs 48.4% | Strong routine-practice evidence; open-label design |
| Maas et al[28], 2024 | Europe/Canada; 7 centers | 581 enrolled; 497 analyzed | CADe | International randomized trial; CADe vs conventional colonoscopy | Patient/procedure | ADR: 38.4% vs 37.7%; APC: 0.66 vs 0.66 | Experienced endoscopists; not statistically significant |
| Yao et al[47], 2024 | China; screening colonoscopy | 393 patients | AI bowel-preparation assessment | Prospective observational validation; AI e-BBPS with tandem colonoscopy outcome assessment | Patient/procedure | > 5-mm AMR: 35.71% in unqualified-AI vs 13.19% in qualified-AI | Single-center observational study; no randomized AI-vs-standard intervention |
Table 3 Representative primary studies of artificial intelligence-assisted endoscopic documentation and report generation
| Ref. | System/input | Setting/sample | Clinical function | Design/comparator | Evaluation unit | Key findings | Validation/main limitation |
| Qu et al[18], 2020 | ISRGS; endoscopic images/video | 46987 images; prospective set: 5699 images | Site/lesion recognition and structured report generation | Multicenter development and prospective validation | Image/patient | Overall diagnostic accuracy: 88.41% multicenter; 89.65% prospective | Multicenter data, but structured/template-based output |
| Dong et al[65], 2022 | EAIRS; real-time EGD video | 210198 development images; 161 prospective patients | Automated photo-documentation | Internal, external and prospective testing; system vs endoscopists | Patient/procedure | Landmark capture accuracy 95.2%; completeness: 93.1% vs 88.8%; detected-lesion capture: 99% vs 98% | Multicenter development; mainly image documentation rather than full narrative report |
| Yokota et al[67], 2022 | Voice Capture/speech input | 356 patients; 101 propensity-matched pairs | Speech-assisted structured reporting | Retrospective propensity-matched comparison; voice recognition vs manual entry | Procedure | Median report preparation time: 311 s vs 383 s, P = 0.009 | Single-center retrospective study |
| Zhang et al[19], 2023 | AI-EARS; EGD video/image | 252111 images for training, 62706 images, and 950 videos for testing | Automatic image capture, diagnosis and textual description | Multireader multicase randomized crossover; AI-EARS vs conventional reporting | Report/procedure | Text completeness: 79.03% vs 51.86%; accuracy: 64.47% vs 42.81%; reporting time: 46.47 s vs 80.13 s | Relatively small clinical crossover sample |
| Naito et al[20], 2025 | AR-C1; video/procedural events | 40 endoscopic mucosal resection procedures | Procedure-event capture and report support | Retrospective clinical comparison | Procedure/report | Report generation time: 186.6 s vs 258.4 s | Single-center and single examiner |
| You et al[66], 2026 | AI gastric-lesion reporting system | 276 video clips; prospective clinical analysis: 100 patients | Structured lesion documentation | Prospective AI-assisted vs routine reporting | Lesion/report | Overall lesion-report completeness: 86.5% vs 75.11%, P = 0.001 | Prospective but single-center |
| Kawagoe et al[68], 2026 | EVAS voice recognition | 21 cases; 5 experienced endoscopists | Voice-assisted colonoscopy reporting | Pilot comparison; EVAS vs manual typing | Report | Mean reporting time: 29 s vs 56 s; 46.3% reduction | Very small pilot; recognition accuracy/system integration require further evaluation |
| Jiang et al[21], 2026 | Report-Angel; endoscopic images/videos + text | 20617 training image-text pairs; prospective internal n = 300 and external n = 300 cohorts | MLLM-generated draft EGD reports | Prospective internal and external clinical validation; expert review of generated drafts | Case/report + lesion | Clinically acceptable draft reports: 79.3% internal, 83.3% external; case completeness 88.51%, accuracy 78.93% | Strongest current prospective MLLM evidence; generated drafts still require clinician review |
| Massimi et al[71], 2026 | Gemini 2.5 Pro; complete EGD video | 5 full-length EGD videos | MLLM video analysis and report generation | Retrospective paired pilot; clean video vs same video with CAD overlay | Report/event | Adequate completeness: 56% vs 48%; landmark accuracy: 0.55 vs 0.33 | Extremely small pilot; authors concluded performance was inadequate for clinical EGD reporting |
Table 4 Proposed clinician-in-the-loop evaluation framework for artificial intelligence-generated endoscopy reports
| Dimension | Clinician assessment | Scale | Suggested outcome |
| Factual grounding | Verify findings against source evidence | Item-level correct/incorrect | Accuracy; hallucination rate |
| Completeness | Check required report elements | Present/absent | Completeness; omission rate |
| Clinical safety | Grade consequences of errors | Minor/moderate/major | Major-error rate |
| Overall acceptability | Determine need for substantive correction | Yes/no | Clinically acceptable report rate |
| Workflow utility | Assess usability and editing burden | Likert scale + time | Utility score; correction time |