BPG is committed to discovery and dissemination of knowledge
Minireviews
Copyright: ©Author(s) 2026.
World J Gastrointest Endosc. Nov 16, 2026; 18(11): 126153
Published online Nov 16, 2026. doi: 10.4253/wjge.126153
Table 1 Distinction among multimodal artificial intelligence concepts in gastrointestinal endoscopy
Concept
Direct model input
Key distinction
Typical outputs
Key limitations
Multimodal learning≥ 2 heterogeneous data sourcesBroad fusion/alignment paradigm; not a specific architecturePrediction, cross-modal representation, decision support, structured outputMissing and asynchronous data
VLMImage/video + textLearns visual–language representations or alignmentImage-text alignment, retrieval, annotation, visual descriptionWeak temporal modeling and limited grounding
MLLMVisual + text + multimodal inputLLM-centered generation conditioned on visual inputVisual question answering, draft report generationHallucination and long-video challenges
Text-based LLMTextNo direct access to endoscopic visual inputSummarization, information extraction, patient communicationInability to directly interpret images
Table 2 Representative clinical and diagnostic-validation studies of artificial intelligence across gastrointestinal endoscopy tasks and workflows
Ref.
Region/setting
Population/sample size
AI function
Study design/comparator
Evaluation unit
Key findings
Validation/main limitation
Wang et al[7], 2019China; colonoscopy1058 patients; 522 CADe, 536 controlReal-time CADeProspective randomized trial; CADe vs standard colonoscopyPatientADR: 29.1% vs 20.3%; adenomas/patient: 0.53 vs 0.31Single-center, non-blinded trial; benefit mainly driven by diminutive adenomas
Byrne et al[8], 2019Colonoscopy video125 diminutive-polyp videos; 106 analyzedCADx for adenoma vs hyperplastic polypIndependent video test set; histopathology referenceLesion/videoSensitivity: 98%; specificity: 83%; accuracy: 94%; NPV: 97%Offline video evaluation; 19/125 lesions lacked sufficient prediction confidence; no live clinical trial
Wu et al[9], 2019China; EGD324 randomized; 303 analyzedWISENSE blind-spot monitoringRCT; WISENSE-assisted vs conventional EGDPatient/procedureBlind spot rate: 5.86% vs 22.46%, P < 0.001Single-center trial; procedure-quality endpoint
Gong et al[23], 2020China; colonoscopy704 randomized; 355 ENDOANGEL, 349 controlReal-time CADe/withdrawal-quality supportRandomized trial; ENDOANGEL vs unassisted colonoscopyPatientADR: 16% vs 8%; odds ratio: 2.3, P = 0.001Single-center study; relatively low baseline ADR
Wang et al[24], 2020China; colonoscopy1010 randomized; 962 analyzedReal-time CADeDouble-blind randomized trial; CADe vs sham systemPatientADR: 34% vs 28%; odds ratio: 1.36, P = 0.03Single-center; interval-CRC benefit not evaluated
Repici et al[25], 2020Italy; colonoscopy685 participants; 341 CADe, 344 controlGI Genius CADeMulticenter randomized trial; CADe vs standard colonoscopyPatient/procedureADR: 54.8% vs 40.4%; APC: 1.07 vs 0.71Multicenter clinical evidence; no long-term cancer-outcome assessment
Shaukat et al[26], 2022United States; screening/surveillance colonoscopy1359 analyzed; 682 CADe, 677 standardSKOUT CADeMulticenter randomized trial; CADe vs standard colonoscopyPatient/procedureADR: 47.8% vs 43.9%, P = 0.065; APC: 1.05 vs 0.83, P = 0.002Multicenter United States evidence; ADR difference not statistically significant
Spada et al[36], 202414 European centers; small-bowel CE137 enrolled; 133 analyzedAI-assisted capsule readingProspective multicenter paired comparison; AI-assisted vs standard readingPatientDiagnostic yield: 73.7% vs 62.4%; reading time: 3.8 minutes vs 33.7 minutesStrong workflow benefit; downstream management and clinical outcomes not evaluated
Seager et al[27], 2024United Kingdom; 12 NHS hospitals2032 randomizedGI Genius CADePragmatic multicenter RCT; CADe vs standard colonoscopyPatient/procedureAdenomas/procedure: 1.56 vs 1.21; ADR: 56.6% vs 48.4%Strong routine-practice evidence; open-label design
Maas et al[28], 2024Europe/Canada; 7 centers581 enrolled; 497 analyzedCADeInternational randomized trial; CADe vs conventional colonoscopyPatient/procedureADR: 38.4% vs 37.7%; APC: 0.66 vs 0.66Experienced endoscopists; not statistically significant
Yao et al[47], 2024China; screening colonoscopy393 patientsAI bowel-preparation assessmentProspective observational validation; AI e-BBPS with tandem colonoscopy outcome assessmentPatient/procedure> 5-mm AMR: 35.71% in unqualified-AI vs 13.19% in qualified-AISingle-center observational study; no randomized AI-vs-standard intervention
Table 3 Representative primary studies of artificial intelligence-assisted endoscopic documentation and report generation
Ref.
System/input
Setting/sample
Clinical function
Design/comparator
Evaluation unit
Key findings
Validation/main limitation
Qu et al[18], 2020ISRGS; endoscopic images/video46987 images; prospective set: 5699 imagesSite/lesion recognition and structured report generationMulticenter development and prospective validationImage/patientOverall diagnostic accuracy: 88.41% multicenter; 89.65% prospectiveMulticenter data, but structured/template-based output
Dong et al[65], 2022EAIRS; real-time EGD video210198 development images; 161 prospective patientsAutomated photo-documentationInternal, external and prospective testing; system vs endoscopistsPatient/procedureLandmark capture accuracy 95.2%; completeness: 93.1% vs 88.8%; detected-lesion capture: 99% vs 98%Multicenter development; mainly image documentation rather than full narrative report
Yokota et al[67], 2022Voice Capture/speech input356 patients; 101 propensity-matched pairsSpeech-assisted structured reportingRetrospective propensity-matched comparison; voice recognition vs manual entryProcedureMedian report preparation time: 311 s vs 383 s, P = 0.009Single-center retrospective study
Zhang et al[19], 2023AI-EARS; EGD video/image252111 images for training, 62706 images, and 950 videos for testingAutomatic image capture, diagnosis and textual descriptionMultireader multicase randomized crossover; AI-EARS vs conventional reportingReport/procedureText completeness: 79.03% vs 51.86%; accuracy: 64.47% vs 42.81%; reporting time: 46.47 s vs 80.13 sRelatively small clinical crossover sample
Naito et al[20], 2025AR-C1; video/procedural events 40 endoscopic mucosal resection proceduresProcedure-event capture and report supportRetrospective clinical comparisonProcedure/reportReport generation time: 186.6 s vs 258.4 sSingle-center and single examiner
You et al[66], 2026AI gastric-lesion reporting system276 video clips; prospective clinical analysis: 100 patientsStructured lesion documentationProspective AI-assisted vs routine reportingLesion/reportOverall lesion-report completeness: 86.5% vs 75.11%, P = 0.001Prospective but single-center
Kawagoe et al[68], 2026EVAS voice recognition21 cases; 5 experienced endoscopistsVoice-assisted colonoscopy reportingPilot comparison; EVAS vs manual typingReportMean reporting time: 29 s vs 56 s; 46.3% reductionVery small pilot; recognition accuracy/system integration require further evaluation
Jiang et al[21], 2026Report-Angel; endoscopic images/videos + text20617 training image-text pairs; prospective internal n = 300 and external n = 300 cohortsMLLM-generated draft EGD reportsProspective internal and external clinical validation; expert review of generated draftsCase/report + lesionClinically acceptable draft reports: 79.3% internal, 83.3% external; case completeness 88.51%, accuracy 78.93%Strongest current prospective MLLM evidence; generated drafts still require clinician review
Massimi et al[71], 2026Gemini 2.5 Pro; complete EGD video5 full-length EGD videosMLLM video analysis and report generationRetrospective paired pilot; clean video vs same video with CAD overlayReport/eventAdequate completeness: 56% vs 48%; landmark accuracy: 0.55 vs 0.33Extremely small pilot; authors concluded performance was inadequate for clinical EGD reporting
Table 4 Proposed clinician-in-the-loop evaluation framework for artificial intelligence-generated endoscopy reports
Dimension
Clinician assessment
Scale
Suggested outcome
Factual groundingVerify findings against source evidenceItem-level correct/incorrectAccuracy; hallucination rate
CompletenessCheck required report elementsPresent/absentCompleteness; omission rate
Clinical safetyGrade consequences of errorsMinor/moderate/majorMajor-error rate
Overall acceptabilityDetermine need for substantive correctionYes/noClinically acceptable report rate
Workflow utilityAssess usability and editing burdenLikert scale + timeUtility score; correction time


Write to the Help Desk