Editorial Open Access
Copyright ©2010 Baishideng. All rights reserved.
World J Gastrointest Endosc. May 16, 2010; 2(5): 143-146
Published online May 16, 2010. doi: 10.4253/wjge.v2.i5.143
Can we improve the diagnostic yield of small bowel video-capsule endoscopy?
Konstantinos Triantafyllou, Hepatogastroenterology Unit, 2nd Department of Internal Medicine - Propaedeutic, Medical School, Athens University, “Attikon” University General Hospital, Haidari 12464, Greece
Author contributions: Triantafyllou K contributed solely to this paper.
Correspondence to: Konstantinos Triantafyllou, MD, PhD, Hepatogastroenterology Unit, 2nd Department of Internal Medicine - Propaedeutic, “Attikon” University General Hospital, Rimini 1, Haidari 12464, Greece. ktriant@med.uoa.gr
Telephone: +30-210-5832090 Fax: +30-210-5326422
Received: September 9, 2009
Revised: March 15, 2010
Accepted: March 22, 2010
Published online: May 16, 2010

Abstract

Video-capsule endoscopy has revolutionized the examination of small bowel mucosa. However, this modality is relatively young and its diagnostic yield is low. Herein, we discuss different approaches to improve examination’s diagnostic yield. There are strong data supporting some of them while there is speculation about the rest. As capsule endoscopy continues to evolve there is also a strong belief that technology will overcome at least some of the obstacles that hamper capsule endoscopy’s diagnostic yield sometime in the near future.

Key Words: Video-capsule endoscopy, Small bowel, diagnostic yield



INTRODUCTION

Small bowel video-capsule endoscopy (VCE) is a powerful, patient friendly and expensive method to examine the small bowel. It has been shown to be superior to any other modality for the examination of small bowel mucosa with a diagnostic yield (DY) around 50%[1,2]. VCE DY is hampered by the presence of food residue, air bubbles and turbid or green viscous intraluminal fluid. Failure of the capsule to visualize the whole small bowel due to delayed gastric (GTT) or small bowel transit time (SBTT) also results in incomplete examinations. Moreover, the technical characteristics of the available capsule endoscopes are not optimal yet and since wireless capsule endoscopy is an evolving technology it is expected that the forthcoming capsule generations may successfully address some of the above issues. Until then, several methods have been proposed in order to increase examination’s DY including use of cathartics and prokinetics, changing body posture, repeating a negative exam etc. with varying results[2].

The lack of established and validated objective measures and criteria to evaluate VCE DY adds further difficulties for the improvement of examination’s DY. Until recently, investigators have used different subjective, unvalidated outcome measures to examine VCE DY and there is no accepted and validated scale to evaluate bowel cleanliness[2,3]. Moreover, many studies are published in abstract form and randomized controlled, adequately powered studies are still in a minority[2].

The vast majority of the information provided in this manuscript refers to published data using the Given Imaging Ltd (Israel) capsule. Given Imaging first delivered wireless capsule endoscopy in 2001. More recently, Olympus (Japan) delivered the Endocapsule, Intro-Medic Co, Ltd (Korea) developed the MiRoCam and finally, Chongqing Jinshan Science and Technology Group (China) launched the OMOM capsule for small bowel examination. Actually, few data are available in the literature concerning the Endocapsule (none regarding our topic) and even less concerning the other two systems (one study regarding VCE completion rate is discussed below).

PURGATIVE BOWEL PREPARATION

The preparation suggested by the capsule manufacturer for VCE (Given Imageing, Yokneam, Israel) is an only clear liquids diet and 8 h fast. However, there is currently strong evidence from a recent meta-analysis that small bowel purgative preparation (polyethylene glycol solution or sodium phosphate) improves examination’s DY[3]. Rokkas et al[3] evaluated data from 12 eligible studies and showed that VCE DY was superior in patients prepared with purgative vs those prepared with a clear liquids diet only [OR (95 % CI) = 1.813 (1.251 - 2.628), P = 0.002]. Increased VCE DY was the result of better quality of mucosa visualization [OR (95 % CI) = 2.113 (1.252 - 3.566), P = 0.005] in patients receiving purgatives. The study did not detect any advantage of purgative bowel preparation regarding VCE completion rate, VCE GTT and VCE SBTT.

While there is evidence of the benefit of bowel preparation for VCE, there is no consensus on the preparation regimen yet. Several investigators favour a half dose of purgative in the evening before the examination[3], other investigators prefer colonoscopy-like preparation[3] while some advocate the administration of the preparation during the examination[4-6]. The meta-analysis of Rokkas et al[3] showed marginal superiority of sodium phosphate over polyethylene glycol regarding the quality of VCE images. However a formal comparison between these two regimens has not been performed yet and a non-randomized prospective study evaluating the quality of small bowel preparation with sodium phosphate or polyethylene glycol did not detect any difference[7].

Bowel purge for VCE might be associated with adverse events and patient intolerance but this has not been reported yet[2]. Moreover, the meta-analysis on bowel preparation for VCE has not detected clinically significant adverse events related to bowel preparation[3].

SIMETHICONE

It has been consistently shown in randomized controlled trials that simethicone improves small bowel mucosa visibility at least in the proximal part of VCE recording by wiping out air bubbles from bowel lumen, either given alone[8-11] or in conjunction with purgatives[4,12,13]. None of the trials showed any benefit of simethicone use regarding VCE completion rate.

PROKINETICS

VCE completion rate is about 80%[1-3]. Retrospective studies have identified factors like inpatient status[14,15], previous abdominal surgery[15,16], poor bowel cleansing[15] and prolonged GTT[15] to predict incomplete small bowel VCE examination. There is still controversy whether advanced age[14,17,18] and diabetes mellitus[15,19,20] predict incomplete VCE studies.

In order to improve VCE completion rate, the use of prokinetics has been studied. The initial studies of oral erythromycin[21] and oral metoclopramide[22] showed marked reduction of the GTT but later studies showed no benefit of using these prokinetics either alone[23-26] or in conjunction with purgatives[13] regarding improving VCE completion rate.

Recent prospective randomized trials with mosapride[27], lubiprostone[28] and bisacodyl[29] also failed to show any benefit regarding the completion rate of the examination and new powerful prokinetics are not on the horizon after the withdrawal of tegaserod.

OTHER INTERVENTIONS

Another approach to improve VCE completion rate could be the follow-up of the capsule in the stomach by using the real-time viewer (Given Imaging, Yoqneam, Israel) which offers real-time inspection of the alimentary lumen peri-procedurally. In case of delayed GTT, intervention with endoscopic advancement of the capsule in the duodenum could be applied[5,30]. Moreover, the use of the real time viewer to optimize the timing for the administration of bowel preparation in order to improve the quality of bowel preparation is promising[5] but it has not been studied extensively yet.

Investigators also studied placing the patient in the right lateral position after swallowing the capsule in order to decrease the GTT but this approached has reached conflicting results; one study in favor and one against[31,32].

In an elegant prospective, randomized, single-blinded controlled trial, 93 consecutive patients were randomized to either use chewing-gum or not in order to determine whether chewing-gum increases the ability of VCE to reach the cecum[33]. Complete VCE examination rate was higher in the chewing-gum group compared with controls (83.0% vs 71.7% respectively, P = 0.19) and both GTT and SBTT were significantly shorter in the chewing-gum vs control group[33]. These data suggest a potential positive role of sham feeding to accelerate the passage of the capsule to the cecum.

One prospective randomized controlled study from China[34] examined the hypothesis that reduction of the image capture rate in the stomach saves battery’s life and thus allows the operating capsule to reach the cecum. Fifty patients who underwent the OMOM [Chongqing Jinshan Science & Technology (Group) Co., Ltd, Chongqing, China] small bowel capsule-endoscopy were randomized into 2 groups: modified image capture rate (initially set at 0.5 frames per second and then modified to 2 frames per second once the capsule passed the pylorus) group and the control group (image capture rate set at 2 frames per second during the entire recording). VCE completion rate was 100% in the modified image capture rate vs 72% in the control group (P = 0.014) showing the impact of technological improvement for the completion of the examination[34].

When there is strong evidence for the presence of small bowel mucosa lesions despite a negative VCE examination, there are several approaches for further evaluation including enteroscopy, radiology or a second capsule endoscopy. Patients with occult gastrointestinal bleeding with nondiagnostic VCE underwent a “second-look VCE” if they manifested a new bleeding episode or a drop in hemoglobin ≥ 2 g/dL[35]. “Second-look VCE” was diagnostic in those patients whose presentation changed from occult to overt or those whose hemoglobin dropped ≥ 4 g/dL showing that a certain proportion of patients with a negative VCE may benefit from the repetition of the examination[35]. However, it has not been tested yet if this approach is cost-effective.

CONCLUSION

Capsule endoscopy is a useful modality to evaluate small bowel mucosa lesions. However, examination’s DY is low. Until the development of new generation capsules equipped with technology that will overcome obstacles such as poor mucosa visibility and limited life span of the battery, purgative bowel preparation and simethicone use are essential to improve the DY of the examination. Dual-camera small bowel capsule endoscopy might also increase DY but it has not been formally tested[36]. Prokinetic use and changing body posture are useless while sham feeding e.g. chewing-gum, might be helpful in order to increase the completion rate of VCE.

Footnotes

Peer reviewer: Sherman M Chamberlain, MD, FACP, FACG, AGAF, Associate Professor of Medicine, Section of Gastroenterology, BBR-2538, Medical College of Georgia, Augusta, GA 30912, United States

S- Editor Zhang HN L- Editor Roemmele A E- Editor Liu N

References
1.  Ladas SD, Triantafyllou K, Spada C, Riccioni ME, Rey JF, Niv Y, Delvaux M, de Franchis R, Costamagna G. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases. Endoscopy. 2010;42:220-227.  [PubMed]  [DOI]  [Cited in This Article: ]
2.  Mergener K, Ponchon T, Gralnek I, Pennazio M, Gay G, Selby W, Seidman EG, Cellier C, Murray J, de Franchis R. Literature review and recommendations for clinical application of small-bowel capsule endoscopy, based on a panel discussion by international experts. Consensus statements for small-bowel capsule endoscopy, 2006/2007. Endoscopy. 2007;39:895-909.  [PubMed]  [DOI]  [Cited in This Article: ]
3.  Rokkas T, Papaxoinis K, Triantafyllou K, Pistiolas D, Ladas SD. Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy? A meta-analysis. Am J Gastroenterol. 2009;104:219-227.  [PubMed]  [DOI]  [Cited in This Article: ]
4.  Shiotani A, Opekun AR, Graham DY. Visualization of the small intestine using capsule endoscopy in healthy subjects. Dig Dis Sci. 2007;52:1019-1025.  [PubMed]  [DOI]  [Cited in This Article: ]
5.  Triantafyllou K, Kalli T, Ladas SD. Small bowel purge after the entrance of the capsule in the duodenum results to better quality of bowel preparation for video-capsule endoscopy. Prospective, randomized, double-blind, placebo-controlled, real time viewer assisted study. Gastrointest Endosc. 2008;134 Suppl 1:A339.  [PubMed]  [DOI]  [Cited in This Article: ]
6.  Rey JF, Repici A, Kuznetsov K, Boyko V, Aabakken L. Optimal preparation for small bowel examinations with video capsule endoscopy. Dig Liver Dis. 2009;41:486-493.  [PubMed]  [DOI]  [Cited in This Article: ]
7.  Triantafyllou K, Papadopoulos AA, Kalantzis C, Apostolopoulos P, Kalli T, Kakavetsi V, Ladas D, Kalantzis N, Ladas SD. Prospective study of the effects of two different small bowel preparations on video-capsule endoscopy completion rate, on the quality of the preparation and on the outcome measures of the examinations. Endoscopy. 2008;40 Suppl 1:A310.  [PubMed]  [DOI]  [Cited in This Article: ]
8.  Albert J, Göbel CM, Lesske J, Lotterer E, Nietsch H, Fleig WE. Simethicone for small bowel preparation for capsule endoscopy: a systematic, single-blinded, controlled study. Gastrointest Endosc. 2004;59:487-491.  [PubMed]  [DOI]  [Cited in This Article: ]
9.  Ge ZZ, Chen HY, Gao YJ, Hu YB, Xiao SD. The role of simeticone in small-bowel preparation for capsule endoscopy. Endoscopy. 2006;38:836-840.  [PubMed]  [DOI]  [Cited in This Article: ]
10.  Esaki M, Matsumoto T, Kudo T, Yanaru-Fujisawa R, Nakamura S, Iida M. Bowel preparations for capsule endoscopy: a comparison between simethicone and magnesium citrate. Gastrointest Endosc. 2009;69:94-101.  [PubMed]  [DOI]  [Cited in This Article: ]
11.  Fang YH, Chen CX, Zhang BL. Effect of small bowel preparation with simethicone on capsule endoscopy. J Zhejiang Univ Sci B. 2009;10:46-51.  [PubMed]  [DOI]  [Cited in This Article: ]
12.  Wei W, Ge ZZ, Lu H, Gao YJ, Hu YB, Xiao SD. Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging. Am J Gastroenterol. 2008;103:77-82.  [PubMed]  [DOI]  [Cited in This Article: ]
13.  Postgate A, Tekkis P, Patterson N, Fitzpatrick A, Bassett P, Fraser C. Are bowel purgatives and prokinetics useful for small-bowel capsule endoscopy? A prospective randomized controlled study. Gastrointest Endosc. 2009;69:1120-1128.  [PubMed]  [DOI]  [Cited in This Article: ]
14.  Ben-Soussan E, Savoye G, Antonietti M, Ramirez S, Lerebours E, Ducrotté P. Factors that affect gastric passage of video capsule. Gastrointest Endosc. 2005;62:785-790.  [PubMed]  [DOI]  [Cited in This Article: ]
15.  Westerhof J, Weersma RK, Koornstra JJ. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009;69:74-80.  [PubMed]  [DOI]  [Cited in This Article: ]
16.  Endo H, Matsuhashi N, Inamori M, Ohya T, Iida H, Mawatari H, Nozaki Y, Yoneda K, Akiyama T, Fujita K. Abdominal surgery affects small bowel transit time and completeness of capsule endoscopy. Dig Dis Sci. 2009;54:1066-1070.  [PubMed]  [DOI]  [Cited in This Article: ]
17.  Fireman Z, Kopelman Y, Friedman S, Ephrath H, Choman E, Debby H, Eliakim R. Age and indication for referral to capsule endoscopy significantly affect small bowel transit times: the given database. Dig Dis Sci. 2007;52:2884-2287.  [PubMed]  [DOI]  [Cited in This Article: ]
18.  Papadopoulos AA, Triantafyllou K, Kalantzis C, Adamopoulos A, Ladas D, Kalli T, Apostolopoulos P, Kalantzis N, Ladas SD. Effects of ageing on small bowel video-capsule endoscopy examination. Am J Gastroenterol. 2008;103:2474-2480.  [PubMed]  [DOI]  [Cited in This Article: ]
19.  Triantafyllou K, Kalantzis C, Papadopoulos AA, Apostolopoulos P, Rokkas T, Kalantzis N, Ladas SD. Video-capsule endoscopy gastric and small bowel transit time and completeness of the examination in patients with diabetes mellitus. Dig Liver Dis. 2007;39:575-580.  [PubMed]  [DOI]  [Cited in This Article: ]
20.  Triantafyllou K, Papadopoulos AA, Kalantzis N, Ladas SD.  Diabetes mellitus is a risk factor for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009;1408-1409; author reply 1409.  [PubMed]  [DOI]  [Cited in This Article: ]
21.  Leung WK, Chan FK, Fung SS, Wong MY, Sung JJ. Effect of oral erythromycin on gastric and small bowel transit time of capsule endoscopy. World J Gastroenterol. 2005;11:4865-4868.  [PubMed]  [DOI]  [Cited in This Article: ]
22.  Selby W. Complete small-bowel transit in patients undergoing capsule endoscopy: determining factors and improvement with metoclopramide. Gastrointest Endosc. 2005;61:80-85.  [PubMed]  [DOI]  [Cited in This Article: ]
23.  Caddy GR, Moran L, Chong AK, Miller AM, Taylor AC, Desmond PV. The effect of erythromycin on video capsule endoscopy intestinal-transit time. Gastrointest Endosc. 2006;63:262-266.  [PubMed]  [DOI]  [Cited in This Article: ]
24.  Fireman Z, Paz D, Kopelman Y. Capsule endoscopy: improving transit time and image view. World J Gastroenterol. 2005;11:5863-5866.  [PubMed]  [DOI]  [Cited in This Article: ]
25.  Niv E, Bonger I, Barkay O, Halpern Z, Mahajna E, Depsames R, Kopelman Y, Fireman Z. Effect of erythromycin on image quality and transit time of capsule endoscopy: a two-center study. World J Gastroenterol. 2008;14:2561-2565.  [PubMed]  [DOI]  [Cited in This Article: ]
26.  Almeida N, Figueiredo P, Freire P, Lopes S, Lérias C, Gouveia H, Leitão MC. The effect of metoclopramide in capsule enteroscopy. Dig Dis Sci. 2010;55:153-157.  [PubMed]  [DOI]  [Cited in This Article: ]
27.  Wei W, Ge ZZ, Lu H, Gao YJ, Hu YB, Xiao SD. Effect of mosapride on gastrointestinal transit time and diagnostic yield of capsule endoscopy. J Gastroenterol Hepatol. 2007;22:1605-1608.  [PubMed]  [DOI]  [Cited in This Article: ]
28.  Hooks SB 3rd, Rutland TJ, Di Palma JA. Lubiprostone neither decreases gastric and small-bowel transit time nor improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled study. Gastrointest Endosc. 2009;70:942-946.  [PubMed]  [DOI]  [Cited in This Article: ]
29.  Franke A, Hummel F, Knebel P, Antoni C, Bocker U, Singer MV, Lohr M. Prospective evaluation of small bowel preparation with bisacodyl and sodium phosphate for capsule endoscopy. World J Gastroenterol. 2008;14:2061-2064.  [PubMed]  [DOI]  [Cited in This Article: ]
30.  Lai LH, Wong GL, Lau JY, Sung JJ, Leung WK. Initial experience of real-time capsule endoscopy in monitoring progress of the videocapsule through the upper GI tract. Gastrointest Endosc. 2007;66:1211-1214.  [PubMed]  [DOI]  [Cited in This Article: ]
31.  Liao Z, Li F, Li ZS. Right lateral position improves complete examination rate of capsule endoscope: a prospective randomized, controlled trial. Endoscopy. 2008;40:483-487.  [PubMed]  [DOI]  [Cited in This Article: ]
32.  Aparicio JR, Martínez J, Casellas JA. Right lateral position does not affect gastric transit times of video capsule endoscopy: a prospective study. Gastrointest Endosc. 2009;69:34-37.  [PubMed]  [DOI]  [Cited in This Article: ]
33.  Apostolopoulos P, Kalantzis C, Gralnek IM, Liatsos C, Tsironis C, Kalantzis N. Clinical trial: effectiveness of chewing-gum in accelerating capsule endoscopy transit time--a prospective randomized, controlled pilot study. Aliment Pharmacol Ther. 2008;28:405-411.  [PubMed]  [DOI]  [Cited in This Article: ]
34.  Liao Z, Li ZS, Xu C. Reduction of capture rate in the stomach increases the complete examination rate of capsule endoscopy: a prospective randomized controlled trial. Gastrointest Endosc. 2009;69:418-425.  [PubMed]  [DOI]  [Cited in This Article: ]
35.  Viazis N, Papaxoinis K, Vlachogiannakos J, Efthymiou A, Theodoropoulos I, Karamanolis DG. Is there a role for second-look capsule endoscopy in patients with obscure GI bleeding after a nondiagnostic first test? Gastrointest Endosc. 2009;69:850-856.  [PubMed]  [DOI]  [Cited in This Article: ]
36.  Triantafyllou K, Papanikolaou IS, Papaxoinis K, Binas I, Karantzas P, Karamanolis G, Ladas SD. Two cameras detect more lesions in the small-bowel than one. Final results of a small-bowel capsule endoscopy feasibility trial with PillCam Colon®. Endoscopy. 2009;41 Suppl 1:A39.  [PubMed]  [DOI]  [Cited in This Article: ]