1
|
Lennerz C, Horlbeck L, Weigand S, Grebmer C, Blazek P, Brkic A, Semmler V, Haller B, Reents T, Hessling G, Deisenhofer I, Lienkamp M, Kolb C, O'Connor M. Patients with pacemakers or defibrillators do not need to worry about e-Cars: An observational study. Technol Health Care 2019; 28:1-12. [PMID: 31744037 DOI: 10.3233/thc-191891] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Electric cars are increasingly used for public and private transportation and represent possible sources of electromagnetic interference (EMI). Potential implications for patients with cardiac implantable electronic devices (CIED) range from unnecessary driving restrictions to life-threatening device malfunction. This prospective, cross-sectional study was designed to assess the EMI risk of electric cars on CIED function. METHODS One hundred and eight consecutive patients with CIEDs presenting for routine follow-up between May 2014 and January 2015 were enrolled in the study. The participants were exposed to electromagnetic fields generated by the four most common electric cars (Nissan Leaf, Tesla Model S, BMW i3, VW eUp) while roller-bench test-driving at Institute of Automotive Technology, Department of Mechanical Engineering, Technical University, Munich. The primary endpoint was any abnormalities in CIED function (e.g. oversensing with pacing-inhibition, inappropriate therapy or mode-switching) while driving or charging electric cars as assessed by electrocardiographic recordings and device interrogation. RESULTS No change in device function or programming was seen in this cohort which is representative of contemporary CIED devices. The largest electromagnetic field detected was along the charging cable during high current charging (116.5 μT). The field strength in the cabin was lower (2.1-3.6 μT). CONCLUSIONS Electric cars produce electromagnetic fields; however, they did not affect CIED function or programming in our cohort. Driving and charging of electric cars is likely safe for patients with CIEDs.
Collapse
Affiliation(s)
- Carsten Lennerz
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany.,German Centre for Cardiovascular Research, Partner Site Munich Heart Alliance, Munich, Germany
| | - Lorenz Horlbeck
- Institute of Automotive Technology, Department of Mechanical Engineering, Technische Universität München, Munich, Germany
| | - Severin Weigand
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany.,German Centre for Cardiovascular Research, Partner Site Munich Heart Alliance, Munich, Germany
| | - Christian Grebmer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Patrick Blazek
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Amir Brkic
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Verena Semmler
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Bernhard Haller
- Klinikum Rechts Der Isar, Institut für Medizinische Statistik und Epidemiologie, Technische Universität München, Munich, Germany
| | - Tilko Reents
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Gabriele Hessling
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Isabel Deisenhofer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Markus Lienkamp
- Institute of Automotive Technology, Department of Mechanical Engineering, Technische Universität München, Munich, Germany
| | - Christof Kolb
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Matthew O'Connor
- Wellington Hospital, Department of Cardiology, Wellington, New Zealand
| |
Collapse
|
3
|
Bandorski D, Kurniawan N, Baltes P, Hoeltgen R, Hecker M, Stunder D, Keuchel M. Contraindications for video capsule endoscopy. World J Gastroenterol 2016; 22:9898-9908. [PMID: 28018097 PMCID: PMC5143757 DOI: 10.3748/wjg.v22.i45.9898] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2016] [Revised: 10/09/2016] [Accepted: 11/16/2016] [Indexed: 02/06/2023] Open
Abstract
Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm.
Collapse
|
4
|
Huang D, Dong ZF, Chen Y, Wang FB, Wei Z, Zhao WB, Li S, Liu MY, Zhu W, Wei M, Li JB. Interference of GSM mobile phones with communication between Cardiac Rhythm Management devices and programmers: A combined in vivo and in vitro study. Bioelectromagnetics 2015; 36:367-76. [PMID: 25864643 DOI: 10.1002/bem.21911] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2014] [Accepted: 02/24/2015] [Indexed: 11/10/2022]
Affiliation(s)
- Dong Huang
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Zhi-Feng Dong
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Yan Chen
- Department of Geratology; Shanghai People's Armed Police Corps Hospital; Shanghai China
| | - Fa-Bin Wang
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Zhi Wei
- St. Jude Medical; Shanghai China
| | | | - Shuai Li
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Ming-Ya Liu
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Wei Zhu
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Meng Wei
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| | - Jing-Bo Li
- Division of Cardiology; the Sixth People's Hospital Affiliated to Shanghai Jiaotong University; Shanghai Jiaotong University School of Medicine; State Key Discipline Division; Shanghai China
| |
Collapse
|
5
|
Cuschieri JR, Osman MN, Wong RC, Chak A, Isenberg GA. Small bowel capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: Outcome analysis using telemetry review. World J Gastrointest Endosc 2012; 4:87-93. [PMID: 22442746 PMCID: PMC3309898 DOI: 10.4253/wjge.v4.i3.87] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Revised: 02/01/2012] [Accepted: 03/01/2012] [Indexed: 02/05/2023] Open
Abstract
AIM: To determine if there were any interactions between cardiac devices and small bowel capsules secondary to electromagnetic interference (EMI) in patients who have undergone small bowel capsule endoscopy (SBCE).
METHODS: Authors conducted a chart review of 20 patients with a cardiac pacemaker (CP) or implantable cardioverter defibrillator (ICD) who underwent continuous electrocardiographic monitoring during their SBCE from 2003-2008. authors searched for unexplained electrocardiogram (ECG) findings, changes in CP and ICD set parameters, any abnormality in transmitted capsule data, and adverse clinical events.
RESULTS: There were no adverse events or hemodynamically significant arrhythmias reported. CP and ICD set parameters were preserved. The majority of ECG abnormalities were also found in pre- or post- SBCE ECG tracings and the CP behavior during arrhythmias appeared appropriate. Two patients seemed to have episodes of undersensing by the CP. However, similar findings were documented in ECGs taken outside the time frame of the SBCE. One patient was observed to have a low signal encountered from the capsule resulting in lack of localization, but no images were lost.
CONCLUSION: Capsule-induced EMI remains a possibility but is unlikely to be clinically important. CP-induced interference of SBCE is also possible, but is infrequent and does not result in loss of images transmitted by the capsule.
Collapse
Affiliation(s)
- Justin R Cuschieri
- Justin R Cuschieri, Division of Gastroenterology, Department of Medicine, Albert Einstein Medical Center, 5401 Old York Road, Klein building suite 363, Philadelphia, PA 19141, United States
| | | | | | | | | |
Collapse
|