1
|
Quintero Bernabeu J, Juamperez Goñi J, Mercadal Hally M, Padrós Fornieles C, Larrarte King M, Molino Gahete JA, Coma Muñoz A, Diez Miranda I, Pérez Lafuente M, Charco Torra R, Hidalgo Llompart E. Less is more: The use of single biodegradable stenting to treat biliary anastomotic strictures in pediatric liver transplantation. Liver Transpl 2025; 31:793-802. [PMID: 39347687 DOI: 10.1097/lvt.0000000000000504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 09/17/2024] [Indexed: 10/01/2024]
Abstract
This study reports our experience of using biodegradable biliary stents (BBSs) for anastomotic biliary strictures (ABSs) in pediatric patients undergoing liver transplants. It involves the analysis of a retrospective data collection from January 2014 to January 2023, including all pediatric recipients of liver transplants in our center treated for ABSs with BBSs. In phase 1 (2014-2019), there was an initial percutaneous transhepatic cholangiography with anastomotic dilatation followed 2 weeks after a second percutaneous transhepatic cholangiography with BBS insertion. In phase 2 (2019-2023), the BBS was placed shortly after ABS dilatation, requiring only 1 percutaneous transhepatic cholangiography. All patients were followed up with routine tests and ultrasound. Forty-six ABSs were diagnosed in 43 pediatric recipients of liver transplants with a median of 6.7 months after liver transplantation (0.1-246.8 mo). Eight out of 46 ABSs (17.4%) treated with BBSs relapsed (median recurrence time: 6.5 mo; 1.6-17.0 mo). Four resolved with further BBS placement; only 4 needed surgical revision (8.7%) after a median follow-up time of 43.9 months (0.3-106.3). There were no differences in ABS recurrence rate, time between stent placement and recurrence, or the presence of cholangitis based on whether the BBS was deployed in 1 or 2 steps. Patients with end-to-end anastomosis had a higher ABS recurrence (OR 10.8; 1.4-81.3, p = 0.008) than those with bilioenteric anastomosis. The use of biodegradable stents could be a good option for treating ABSs in pediatric patients undergoing liver transplants, with our series showing a success rate of over 90% and an average follow-up of 43.9 months.
Collapse
Affiliation(s)
- Jesús Quintero Bernabeu
- Pediatric Hepatology and Liver Transplant Unit, Department of Pediatrics, Vall d'Hebron Hospital Campus, Barcelona, Spain. ERN Rare Liver ERN TransplantChild
| | - Javier Juamperez Goñi
- Pediatric Hepatology and Liver Transplant Unit, Department of Pediatrics, Vall d'Hebron Hospital Campus, Barcelona, Spain. ERN Rare Liver ERN TransplantChild
| | - Maria Mercadal Hally
- Pediatric Hepatology and Liver Transplant Unit, Department of Pediatrics, Vall d'Hebron Hospital Campus, Barcelona, Spain. ERN Rare Liver ERN TransplantChild
| | - Cristina Padrós Fornieles
- Pediatric Hepatology and Liver Transplant Unit, Department of Pediatrics, Vall d'Hebron Hospital Campus, Barcelona, Spain. ERN Rare Liver ERN TransplantChild
| | - Mauricio Larrarte King
- Pediatric Hepatology and Liver Transplant Unit, Department of Pediatrics, Vall d'Hebron Hospital Campus, Barcelona, Spain. ERN Rare Liver ERN TransplantChild
| | | | - Anna Coma Muñoz
- Pediatric Radiology Unit, Radiology Department, Vall d'Hebron Hospital Campus, Barcelona, Spain
| | - Iratxe Diez Miranda
- Interventional Radiology Unit, Radiology Department, Vall d'Hebron Hospital Campus, Barcelona, Spain
| | - Mercedes Pérez Lafuente
- Interventional Radiology Unit, Radiology Department, Vall d'Hebron Hospital Campus, Barcelona, Spain
| | - Ramon Charco Torra
- HPB Surgery and Transplants Department, Vall d'Hebron Hospital Campus, Barcelona, Spain
| | | |
Collapse
|
2
|
Cardoso DR, Barros A, Meneses A, Requicha JF. Biodegradable Stents in Companion Animals: A Systematic Scoping Review. Vet Med Int 2025; 2025:6405530. [PMID: 40224252 PMCID: PMC11986936 DOI: 10.1155/vmi/6405530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 01/23/2025] [Indexed: 04/15/2025] Open
Abstract
Objective: Describe the existing scientific literature regarding the feasibility and behavior of biodegradable stents (BDSs) in companion animals. Study Design: Systematic scoping review. Methods: A literature search was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) and followed the recommendations of the Cochrane Collaboration. The search was performed by using PubMed, Web of Science, and Scopus databases, focusing on BDS usage in companion animals' urinary, respiratory, and digestive systems including choledochal duct. Results: In total, 233 articles were identified but only 21 fulfilled the inclusion criteria. Ninety percent (n = 19) of the investigation was conducted in animal models aiming translational to humans, and only two studies involved clinical cases. Regarding application, 42.9% was focused on the urinary system, 19% assessed vascular stenting, 14.3% esophageal stenting, 19% choledochal duct stenting, and 4.8% tracheal stenting. Polylactic acid (PLA) was the most used biomaterial. Conclusion: This review summarized the use of BDS in companion animals, highlighting that most studies were conducted in animals without clinical disease, with most reporting a low incidence of self-limiting complications. Clinical Significance: This review underscores the potential impact of BDS on companion animals. Further research is necessary to explore BDS's full potential in small animal medicine.
Collapse
Affiliation(s)
- Daiana R. Cardoso
- I-MVET Research in Veterinary Medicine, Faculty of Veterinary Medicine, Lusófona University—Lisbon University Centre, Lisbon, Portugal
- Department of Veterinary Sciences, University of Trás-os-Montes and Alto Douro, Vila Real, Portugal
- Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), Lisbon, Portugal
- Veterinary and Animal Research Center (CECAV), Lusófona University Center, Lisbon, Portugal
| | | | - André Meneses
- I-MVET Research in Veterinary Medicine, Faculty of Veterinary Medicine, Lusófona University—Lisbon University Centre, Lisbon, Portugal
- Veterinary and Animal Research Center (CECAV), Lusófona University Center, Lisbon, Portugal
| | - João F. Requicha
- Department of Veterinary Sciences, University of Trás-os-Montes and Alto Douro, Vila Real, Portugal
- Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), Lisbon, Portugal
- Animal and Veterinary Research Centre (CECAV), University of Trás-os-Montes e Alto Douro (UTAD), Vila Real, Portugal
| |
Collapse
|
3
|
Li Y, Yuan K, Deng C, Tang H, Wang J, Dai X, Zhang B, Sun Z, Ren G, Zhang H, Wang G. Biliary stents for active materials and surface modification: Recent advances and future perspectives. Bioact Mater 2024; 42:587-612. [PMID: 39314863 PMCID: PMC11417150 DOI: 10.1016/j.bioactmat.2024.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 08/27/2024] [Accepted: 08/27/2024] [Indexed: 09/25/2024] Open
Abstract
Demand for biliary stents has expanded with the increasing incidence of biliary disease. The implantation of plastic or self-expandable metal stents can be an effective treatment for biliary strictures. However, these stents are nondegradable and prone to restenosis. Surgical removal or replacement of the nondegradable stents is necessary in cases of disease resolution or restenosis. To overcome these shortcomings, improvements were made to the materials and surfaces used for the stents. First, this paper reviews the advantages and limitations of nondegradable stents. Second, emphasis is placed on biodegradable polymer and biodegradable metal stents, along with functional coatings. This also encompasses tissue engineering & 3D-printed stents were highlighted. Finally, the future perspectives of biliary stents, including pro-epithelialization coatings, multifunctional coated stents, biodegradable shape memory stents, and 4D bioprinting, were discussed.
Collapse
Affiliation(s)
- Yuechuan Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Kunshan Yuan
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Chengchen Deng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Hui Tang
- Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200092, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Jinxuan Wang
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
| | - Xiaozhen Dai
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
| | - Bing Zhang
- Nanjing Key Laboratory for Cardiovascular Information and Health Engineering Medicine (CVIHEM), Drum Tower Hospital, Nanjing University, Nanjing, China
| | - Ziru Sun
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
- College of materials science and engineering, Shandong University of Technology, Zibo, 25500, Shandong, China
| | - Guiying Ren
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
- College of materials science and engineering, Shandong University of Technology, Zibo, 25500, Shandong, China
| | - Haijun Zhang
- Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200092, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
- Nanjing Key Laboratory for Cardiovascular Information and Health Engineering Medicine (CVIHEM), Drum Tower Hospital, Nanjing University, Nanjing, China
| |
Collapse
|
4
|
Ni DJ, Yang QF, Nie L, Xu J, He SZ, Yao J. The past, present, and future of endoscopic management for biliary strictures: technological innovations and stent advancements. Front Med (Lausanne) 2024; 11:1334154. [PMID: 39669990 PMCID: PMC11634603 DOI: 10.3389/fmed.2024.1334154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 11/15/2024] [Indexed: 12/14/2024] Open
Abstract
Biliary stricture can be induced by intrinsic narrowing and extrinsic compression, with the majority of cases being malignant. Clinically, distinguishing between benign and malignant biliary strictures remains a considerable challenge, and the ongoing disagreement over the optimal choice of biliary stents significantly influences treatment strategies and impacts patients' survival and prognosis. The utilization and advancement of endoscopic techniques have heightened the diagnostic sensitivity for biliary strictures. Concurrently, innovative technologies such as endoscopic ultrasound and magnetic compression anastomosis emerge as viable alternatives when endoscopic retrograde cholangiopancreatography (ERCP) is not an option, providing fresh insights for the clinical management of these patients. Traditional plastic and metal stents, characterized by their complex application and limited scope, have been unable to fully satisfy clinical needs. The introduction of novel stent varieties has notably improved this scenario, marking a considerable progression towards precision medicine. However, the clinical validation of the diverse stent materials available is incomplete. Hence, a thorough discussion on the present state and evolving trends of biliary stents is warranted.
Collapse
Affiliation(s)
- Dong-Jin Ni
- Department of Gastroenterology, The Affiliated People's Hospital of Jiangsu University, Zhenjiang, China
| | - Qi-Fan Yang
- Department of Gastroenterology, The Affiliated People's Hospital of Jiangsu University, Zhenjiang, China
| | - Lu Nie
- Department of Intervention Vascular, Wujin Hospital Affiliated with Jiangsu University, Changzhou, China
| | - Jian Xu
- Department of Gastroenterology, The Affiliated People's Hospital of Jiangsu University, Zhenjiang, China
| | - Si-Zhe He
- Shanghai Academy of Fine Arts, Shanghai University, Shanghai, China
| | - Jun Yao
- Department of Gastroenterology, The Affiliated People's Hospital of Jiangsu University, Zhenjiang, China
| |
Collapse
|
5
|
Klabukov I, Tenchurin T, Shepelev A, Baranovskii D, Mamagulashvili V, Dyuzheva T, Krasilnikova O, Balyasin M, Lyundup A, Krasheninnikov M, Sulina Y, Gomzyak V, Krasheninnikov S, Buzin A, Zayratyants G, Yakimova A, Demchenko A, Ivanov S, Shegay P, Kaprin A, Chvalun S. Biomechanical Behaviors and Degradation Properties of Multilayered Polymer Scaffolds: The Phase Space Method for Bile Duct Design and Bioengineering. Biomedicines 2023; 11:745. [PMID: 36979723 PMCID: PMC10044742 DOI: 10.3390/biomedicines11030745] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 03/06/2023] Open
Abstract
This article reports the electrospinning technique for the manufacturing of multilayered scaffolds for bile duct tissue engineering based on an inner layer of polycaprolactone (PCL) and an outer layer either of a copolymer of D,L-lactide and glycolide (PLGA) or a copolymer of L-lactide and ε-caprolactone (PLCL). A study of the degradation properties of separate polymers showed that flat PCL samples exhibited the highest resistance to hydrolysis in comparison with PLGA and PLCL. Irrespective of the liquid-phase nature, no significant mass loss of PCL samples was found in 140 days of incubation. The PLCL- and PLGA-based flat samples were more prone to hydrolysis within the same period of time, which was confirmed by the increased loss of mass and a significant reduction of weight-average molecular mass. The study of the mechanical properties of developed multi-layered tubular scaffolds revealed that their strength in the longitudinal and transverse directions was comparable with the values measured for a decellularized bile duct. The strength of three-layered scaffolds declined significantly because of the active degradation of the outer layer made of PLGA. The strength of scaffolds with the PLCL outer layer deteriorated much less with time, both in the axial (p-value = 0.0016) and radial (p-value = 0.0022) directions. A novel method for assessment of the physiological relevance of synthetic scaffolds was developed and named the phase space approach for assessment of physiological relevance. Two-dimensional phase space (elongation modulus and tensile strength) was used for the assessment and visualization of the physiological relevance of scaffolds for bile duct bioengineering. In conclusion, the design of scaffolds for the creation of physiologically relevant tissue-engineered bile ducts should be based not only on biodegradation properties but also on the biomechanical time-related behavior of various compositions of polymers and copolymers.
Collapse
Affiliation(s)
- Ilya Klabukov
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
- Department of Urology and Operative Nephrology, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
- Obninsk Institute for Nuclear Power Engineering, National Research Nuclear University MEPhI, 115409 Obninsk, Russia
| | - Timur Tenchurin
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
| | - Alexey Shepelev
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
| | - Denis Baranovskii
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
- Department of Urology and Operative Nephrology, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
| | - Vissarion Mamagulashvili
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
| | - Tatiana Dyuzheva
- Department of Hospital Surgery, Sklifosovsky Institute of Clinical Medicine, Sechenov First Moscow State Medical University (Sechenov University), 119435 Moscow, Russia
| | - Olga Krasilnikova
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
| | - Maksim Balyasin
- Research and Educational Resource Center for Cellular Technologies, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
| | - Alexey Lyundup
- Research and Educational Resource Center for Cellular Technologies, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
- N.P. Bochkov Research Centre for Medical Genetics, 115478 Moscow, Russia
| | - Mikhail Krasheninnikov
- Research and Educational Resource Center for Cellular Technologies, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
- Lomonosov Institute of Fine Chemical Technologies, Russian Technological University MIREA, 119454 Moscow, Russia
| | - Yana Sulina
- Department of Obstetrics and Gynecology, Sechenov First Moscow State Medical University (Sechenov University), 119435 Moscow, Russia
| | - Vitaly Gomzyak
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
| | - Sergey Krasheninnikov
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
| | - Alexander Buzin
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
- Laboratory of the Structure of Polymer Materials, Enikolopov Institute of Synthetic Polymer Materials RAS, 117393 Moscow, Russia
| | - Georgiy Zayratyants
- Department of Pathology, Moscow State University of Medicine and Dentistry, Delegatskaya st., 20, p. 1, 127473 Moscow, Russia
| | - Anna Yakimova
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
| | - Anna Demchenko
- N.P. Bochkov Research Centre for Medical Genetics, 115478 Moscow, Russia
| | - Sergey Ivanov
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
| | - Peter Shegay
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
- Department of Urology and Operative Nephrology, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
| | - Andrey Kaprin
- Department of Regenerative Medicine, National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, 249031 Obninsk, Russia
- Department of Urology and Operative Nephrology, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia
| | - Sergei Chvalun
- National Research Centre “Kurchatov Institute”, 1, Akademika Kurchatova pl., 123182 Moscow, Russia
- Laboratory of the Structure of Polymer Materials, Enikolopov Institute of Synthetic Polymer Materials RAS, 117393 Moscow, Russia
| |
Collapse
|
6
|
Sulieman I, Elaffandi A, Elmoghazy W, Khalaf H. USE of Biodegradable STENTS in Pancreaticoduodenectomy: Initial Experience. Surg Innov 2022:15533506221123355. [PMID: 36148813 DOI: 10.1177/15533506221123355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background. Plastic stents have been used to avoid postoperative pancreatic fistula (POPF) following Whipple's Pancreaticoduodenectomy (WPD), but they may cause some stent-related complications. Biodegradable stents have been recently introduced and might be a safe alternative. Here we present our initial experience with their use. Methods. Between March 1, 2020, and September 30, 2020, ten (10) consecutive patients underwent WPD. They all had conventional two-layer pancreaticojejunostomy with the placement of an internal biodegradable stent. They were assessed for technical feasibility, pancreatic leak, and stent-related complications. Results. The use of biodegradable stents was technically feasible in all patients, despite some difficulties in insertion due to stent stiffness and design. After a median follow-up period of 124 days, none of the patients suffered POPF. One patient had a biochemical pancreatic leak with no clinical significance. The median hospital stay was 7 days, and there were no stent-related complications. Conclusion. Biodegradable stents are technically feasible and safe in WPD with good short-term outcomes. They might provide a better alternative to plastic stents and their potential complications. Larger long-term studies are needed to validate efficacy and safety. Few modifications of the stent's design might be needed to facilitate use in open surgery.
Collapse
Affiliation(s)
- Ibnouf Sulieman
- Department of Surgery, Division of Organ Transplant, 36977Hamad General Hospital, Doha, Qatar
| | - Ahmed Elaffandi
- Department of Surgery, Division of Organ Transplant, 36977Hamad General Hospital, Doha, Qatar.,Department of Surgical Oncology, National Cancer Institute, 36977Cairo University, Egypt
| | - Walid Elmoghazy
- Department of Surgery, Division of Organ Transplant, 36977Hamad General Hospital, Doha, Qatar.,Department of Surgery, 36977Sohag University, Sohag, Egypt
| | - Hatem Khalaf
- Department of Surgery, Division of Organ Transplant, 36977Hamad General Hospital, Doha, Qatar.,Department of Surgery, College of Medicine, 36977Qatar University, Qatar
| |
Collapse
|
7
|
Song G, Zhao HQ, Liu Q, Fan Z. A review on biodegradable biliary stents: materials and future trends. Bioact Mater 2022; 17:488-495. [PMID: 35415292 PMCID: PMC8968460 DOI: 10.1016/j.bioactmat.2022.01.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 12/28/2021] [Accepted: 01/10/2022] [Indexed: 12/12/2022] Open
Abstract
Biliary stricture is defined as the reduction and narrowing of the bile duct lumen, which can be caused by many factors such as cancer and inflammation. Biliary stent placement can effectively alleviate benign and malignant biliary strictures. However, the commonly used plastic or metallic biliary stents are far from ideal and do not satisfy all clinical requirements,although several types of biodegradable biliary stents have been developed and used clinically. In this review, we summarized current development status of biodegradable stents with the emphasis on the stent materials. We also presented the future development trends based on the published literature.
Summary of current development status of bioresorbable biliary stents with the emphasis on the stent materials. The future development trends based on the published literature. The advantages of bioresorbable biliary stents compared with metallic and plastic biliary stents.
Collapse
|
8
|
Tian Y, Liu M, Liu W, Cheng J, Wu G, Han T, Zhang Y, Zhao G, Ni Z. Effects of annealing temperature on both radial supporting performance and axial flexibility of poly(L‐lactic acid) braided stents. J Appl Polym Sci 2021. [DOI: 10.1002/app.50517] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Yuan Tian
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments Southeast University Nanjing China
| | - Muqing Liu
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments Southeast University Nanjing China
| | - Wentao Liu
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments Southeast University Nanjing China
| | - Jie Cheng
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments Southeast University Nanjing China
| | - Gensheng Wu
- School of Mechanical and Electronic Engineering Nanjing Forestry University Nanjing China
| | - Ting Han
- Department of Thermal Analysis Instrument Mettler‐Toledo Company Shanghai China
| | - Yi Zhang
- Center of Interventional Radiology & Vascular Surgery, Department of Radiology, Zhongda Hospital, Medical School Southeast University Nanjing China
| | - Gutian Zhao
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments Southeast University Nanjing China
| | - Zhonghua Ni
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments Southeast University Nanjing China
| |
Collapse
|
9
|
Tian Y, Zhang J, Cheng J, Wu G, Zhang Y, Ni Z, Zhao G. A poly(L‐lactic acid) monofilament with high mechanical properties for application in biodegradable biliary stents. J Appl Polym Sci 2021. [DOI: 10.1002/app.49656] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Yuan Tian
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments, Southeast University Nanjing China
| | - Jing Zhang
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments, Southeast University Nanjing China
| | - Jie Cheng
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments, Southeast University Nanjing China
| | - Gensheng Wu
- School of Mechanical and Electronic Engineering, Nanjing Forestry University Nanjing China
| | - Yi Zhang
- Center of Interventional Radiology & Vascular Surgery, Department of Radiology Zhongda Hospital, Medical School, Southeast University Nanjing China
| | - Zhonghua Ni
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments, Southeast University Nanjing China
| | - Gutian Zhao
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro‐Nano Biomedical Instruments, Southeast University Nanjing China
| |
Collapse
|
10
|
Battistel M, Senzolo M, Ferrarese A, Lupi A, Cillo U, Boccagni P, Zanus G, Stramare R, Quaia E, Burra P, Barbiero G. Biodegradable Biliary Stents for Percutaneous Treatment of Post-liver Transplantation Refractory Benign Biliary Anastomotic Strictures. Cardiovasc Intervent Radiol 2020; 43:749-755. [PMID: 32133551 DOI: 10.1007/s00270-020-02442-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Accepted: 02/22/2020] [Indexed: 12/13/2022]
Abstract
PURPOSE The aim of this study was to evaluate the safety and the effectiveness of polydioxanone-made biodegradable biliary stent placement for the treatment of post-transplant benign, refractory biliary anastomotic strictures. MATERIALS AND METHODS This was a retrospective observational study on all adult liver transplant recipients who developed a clinically significant anastomotic stricture between January 2014 and June 2017. Percutaneous transhepatic cholangioplasty with balloon dilation was performed as therapeutic approach in selected patients after multidisciplinary evaluation. Refractory strictures (defined as stricture persistence after two interventional procedures) were managed with placement of polydioxanone-made biodegradable biliary stent (SX-Ella biliary stent, Czech Republic). Patency of the common bile duct was calculated using Kaplan-Meier analysis. RESULTS Eighteen adult liver transplant recipients who developed a refractory biliary anastomotic stricture [males/females 13/5, median (IQR) 58.2 (9.3) years] underwent biodegradable biliary stent placement after 10.4 (32) months from liver transplantation. All procedures except one were uneventful. After a median (IQR) follow-up time of 27.2 (22) months, complete resolution of anastomotic stricture was achieved in 72% of patients, with significant improvement on liver enzymes. CONCLUSIONS Polydioxanone-made biodegradable biliary stent might be a safe and effective therapeutic option for the difficult-to-treat benign biliary anastomotic stricture after liver transplantation.
Collapse
Affiliation(s)
| | - Marco Senzolo
- Multivisceral Transplant Unit, Padua University Hospital, Padua, Italy
| | - Alberto Ferrarese
- Multivisceral Transplant Unit, Padua University Hospital, Padua, Italy
| | - Amalia Lupi
- University Radiology Unit, Padua University Hospital, Padua, Italy
| | - Umberto Cillo
- Hepatobiliary Surgery and Liver Transplant Center, Padua University Hospital, Padua, Italy
| | - Patrizia Boccagni
- Hepatobiliary Surgery and Liver Transplant Center, Padua University Hospital, Padua, Italy
| | - Giacomo Zanus
- Hepatobiliary Surgery and Liver Transplant Center, Padua University Hospital, Padua, Italy
| | - Roberto Stramare
- University Radiology Unit, Padua University Hospital, Padua, Italy
| | - Emilio Quaia
- University Radiology Unit, Padua University Hospital, Padua, Italy
| | - Patrizia Burra
- Multivisceral Transplant Unit, Padua University Hospital, Padua, Italy
| | - Giulio Barbiero
- University Radiology Unit, Padua University Hospital, Padua, Italy.
| |
Collapse
|
11
|
De Gregorio MA, Criado E, Guirola JA, Alvarez-Arranz E, Pérez-Lafuente M, Barrufet M, Ferrer-Puchol MD, Lopez-Minguez S, Urbano J, Lanciego C, Aguinaga A, Capel A, Ponce-Dorrego MD, Gregorio A. Absorbable stents for treatment of benign biliary strictures: long-term follow-up in the prospective Spanish registry. Eur Radiol 2020; 30:4486-4495. [PMID: 32221684 DOI: 10.1007/s00330-020-06797-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 03/01/2020] [Accepted: 03/09/2020] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Benign strictures of the bile duct may be difficult to treat endoscopically due to altered bowel anatomy. Furthermore, recurrence of stenosis and symptoms remains high. The aim of the Spanish Prospective Registry BiELLA study was to investigate the safety and efficacy of absorbable stents in the treatment of benign biliary strictures and their outcomes on the medium and long-term follow-up. METHODS A prospective, multicenter, observational, non-randomized study (the BiELLA study) was conducted from January 2014 to September 2018. One hundred fifty-nine patients with benign biliary strictures, mostly postsurgical, were enrolled for implantation of absorbable biliary stents in the 11 participating Spanish tertiary hospitals. The average patient follow-up was 45.4 ± 15.9 months (range, 12-60 months). The follow-up data included symptoms, biochemical parameters, and ultrasound images at 1, 6, and 12 months and then yearly for up to 60 months. RESULTS The immediate technical and clinical success rates were 100%. In all patients, stent placement resulted in improvement of clinical symptoms and biochemical parameters. The primary mean patency for stent was 86.7, 79.6, and 78.9% at 12, 36, and 60 months, respectively (95% CI). Biliary restenosis and occlusion occurred in 40 (26.6%) patients. Of the 40 patients, 18 (12%) patients were treated with a second stent and 22 (14.6%) patients had operative repair of the recurrent strictures. There were no major complications associated with stent implantation. CONCLUSIONS Implantation of an absorbable polydioxanone biliary stent is safe and effective for treatment of benign biliary strictures refractory to balloon dilatation or other biliary intervention. KEY POINTS • Percutaneous implantation of biodegradable prostheses for the treatment of benign postsurgical biliary strictures is a safe and effective procedure. • More than 75% of the patients presented patency of the stented biliary tree at 5 years follow-up. • Absorbable stents improved clinical symptoms and signs (jaundice, itching, fever), and laboratory parameters in a few days after stent placement.
Collapse
Affiliation(s)
- Miguel A De Gregorio
- Interventional Radiology Research Group (GITMI), University of Zaragoza, Zaragoza, Spain
| | - Eva Criado
- Interventional Radiology Unit, UDIAT-Centre Diagnòstic, Hospital Universitario Parc Tauli Sabadell, Medicine Department Universidad Autónoma de Barcelona, Barcelona, Spain
| | - Jose A Guirola
- Interventional Radiology Research Group (GITMI), University of Zaragoza, Zaragoza, Spain
| | - Enrique Alvarez-Arranz
- Interventional Radiology Research Group (GITMI), University of Zaragoza, Zaragoza, Spain.
| | | | - Marta Barrufet
- Interventional Radiology Unit, Hospital Clínic i Provincial, Barcelona, Spain
| | - Maria D Ferrer-Puchol
- Interventional Radiology Unit, Hospital Universitario La Ribera, Alzira, Valencia, Spain
| | - Sandra Lopez-Minguez
- Interventional Radiology Research Group (GITMI), University of Zaragoza, Zaragoza, Spain
| | - Jose Urbano
- Interventional Radiology Unit, Hospitales Vithas, Madrid, Spain
| | - Carlos Lanciego
- Interventional Radiology Unit, Hospital Universitario Virgen de la Salud, Toledo, Spain
| | - Alexander Aguinaga
- Interventional Radiology Unit, Hospital Universitario de Cruces, Bilbao, Spain
| | - Antonio Capel
- Interventional Radiology Unit, Hospital Universitario Virgen de la Arrixaca, Murcia, Spain
| | | | - Abel Gregorio
- Interventional Radiology Unit, Hospital de Denia Marina Salud, Alicante, Spain
| | | |
Collapse
|
12
|
A systematic review of biodegradable biliary stents: promising biocompatibility without stent removal. Eur J Gastroenterol Hepatol 2018; 30:813-818. [PMID: 29782386 DOI: 10.1097/meg.0000000000001167] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Biodegradable self-expanding stents are an emerging alternative to standard biliary stents as the development of endoscopic insertion devices advances. The aim was to systematically review the existing literature on biodegradable biliary stents. In-vivo studies on the use of biodegradable stents in the biliary duct were systematically reviewed from 1990 to 2017. Despite extensive research on the biocompatibility of stents, the experience so far on their clinical use is limited. A few favorable reports have recently been presented on endoscopically and percutaneously inserted self-expanding biodegradable polydioxanone stents in benign biliary strictures. Another potential indication appears to be postcholecystectomy leak of the cystic duct. The main benefit of biodegradable stents is that stent removal can be avoided. The biocompatibility of the current biodegradable stent materials, most prominently polydioxanone, is well documented. In the few studies currently available, biodegradable stents are reported to be feasible and safe, also in humans. The initial results of the endoscopic use of these stents in benign biliary stricture management and for treating postcholecystectomy bile leaks are promising. Further controlled studies on long-term clinical results and cost-effectiveness are needed.
Collapse
|
13
|
Dopazo C, Diez I, Quintero J, Curell A, González-Junyent C, Caralt M, Pando E, Lázaro JL, Molino JA, Juamperez J, Castells L, Pérez M, Bilbao I, Segarra A, Charco R. Role of Biodegradable Stents as Part of Treatment of Biliary Strictures after Pediatric and Adult Liver Transplantation: An Observational Single-Center Study. J Vasc Interv Radiol 2018; 29:899-904. [DOI: 10.1016/j.jvir.2018.02.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 01/30/2018] [Accepted: 02/05/2018] [Indexed: 12/15/2022] Open
|
14
|
Zhu Y, Yang K, Cheng R, Xiang Y, Yuan T, Cheng Y, Sarmento B, Cui W. The current status of biodegradable stent to treat benign luminal disease. MATERIALS TODAY 2017; 20:516-529. [DOI: 10.1016/j.mattod.2017.05.002] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
|
15
|
Trela JM, Dechant JE, Culp WT, Whitcomb MB, Palm CA, Nieto JE. Use of an Absorbable Urethral Stent for the Management of a Urethral Stricture in a Stallion. Vet Surg 2016; 45:O41-O48. [DOI: 10.1111/vsu.12530] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Accepted: 05/26/2016] [Indexed: 11/28/2022]
Affiliation(s)
- Jan M. Trela
- School of Veterinary Medicine; University of California-Davis; Davis California
| | - Julie E. Dechant
- School of Veterinary Medicine; University of California-Davis; Davis California
| | - William T. Culp
- School of Veterinary Medicine; University of California-Davis; Davis California
| | - Mary B. Whitcomb
- School of Veterinary Medicine; University of California-Davis; Davis California
| | - Carrie A. Palm
- School of Veterinary Medicine; University of California-Davis; Davis California
| | - Jorge E. Nieto
- School of Veterinary Medicine; University of California-Davis; Davis California
| |
Collapse
|
16
|
Giménez ME, Palermo M, Houghton E, Acquafresca P, Finger C, Verde JM, Cúneo JC. BIODEGRADABLE BILIARY STENTS: A NEW APPROACH FOR THE MANAGEMENT OF HEPATICOJEJUNOSTOMY STRICTURES FOLLOWING BILE DUCT INJURY. PROSPECTIVE STUDY. ARQUIVOS BRASILEIROS DE CIRURGIA DIGESTIVA : ABCD = BRAZILIAN ARCHIVES OF DIGESTIVE SURGERY 2016; 29:112-6. [PMID: 27438039 PMCID: PMC4944748 DOI: 10.1590/0102-6720201600020012] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Accepted: 02/16/2016] [Indexed: 11/29/2022]
Abstract
BACKGROUND Once a biliary injury has occurred, repair is done by a hepaticojejunostomy. The most common procedure is to perform a dilatation with balloon with a success of 70 %. Success rates range using biodegradable stents is from 85% to 95%. Biodegradable biliary stents should change the treatment of this complication. AIM To investigate the use of biodegradable stents in a group of patients with hepaticojejunonostomy strictures. METHODS In a prospective study 16 biodegradable stents were placed in 13 patients with hepaticojejunostomy strictures secondary to bile duct repair of a biliary surgical injury. Average age was 38.7 years (23-67), nine were female and four male. All cases had a percutaneous drainage before at the time of biodegradable stent placement. RESULTS In one case, temporary haemobilia was present requiring blood transfusion. In another, pain after stent placement required intravenous medication. In the other 11 patients, hospital discharge was the next morning following stent placement. During the patient´s follow-up, none presented symptoms during the first nine months. One patient presented significant alkaline phosphatase elevation and stricture recurrence was confirmed. One case had recurrence of cholangitis 11 months after the stent placement. 84.6% continued asymptomatic with a mean follow-up of 20 months. CONCLUSION The placement of biodegradable stents is a safe and feasible technique. Was not observed strictures caused by the stent or its degradation. It could substitute balloon dilation in strictures of hepaticojejunostomy.
Collapse
Affiliation(s)
- Mariano E Giménez
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| | - Mariano Palermo
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| | - Eduardo Houghton
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| | - Pablo Acquafresca
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| | - Caetano Finger
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| | - Juan M Verde
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| | - Jorge Cardoso Cúneo
- Docencia, Asistencia e Investigación en Cirugía Invasiva Mínima - DAICIM Foundation, Buenos Aires, Argentina
| |
Collapse
|
17
|
Mauri G, Michelozzi C, Melchiorre F, Poretti D, Pedicini V, Salvetti M, Criado E, Falcò Fages J, De Gregorio MÁ, Laborda A, Sonfienza LM, Cornalba G, Monfardini L, Panek J, Andrasina T, Gimenez M. Benign biliary strictures refractory to standard bilioplasty treated using polydoxanone biodegradable biliary stents: retrospective multicentric data analysis on 107 patients. Eur Radiol 2016; 26:4057-4063. [DOI: 10.1007/s00330-016-4278-6] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 12/23/2015] [Accepted: 02/08/2016] [Indexed: 01/20/2023]
|
18
|
Ferreira R, Loureiro R, Nunes N, Santos AA, Maio R, Cravo M, Duarte MA. Role of endoscopic retrograde cholangiopancreatography in the management of benign biliary strictures: What’s new? World J Gastrointest Endosc 2016; 8:220-231. [PMID: 26962404 PMCID: PMC4766255 DOI: 10.4253/wjge.v8.i4.220] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 08/18/2015] [Accepted: 12/15/2015] [Indexed: 02/05/2023] Open
Abstract
Benign biliary strictures comprise a heterogeneous group of diseases. The most common strictures amenable to endoscopic treatment are post-cholecystectomy, post-liver transplantation, related to primary sclerosing cholangitis and to chronic pancreatitis. Endoscopic treatment of benign biliary strictures is widely used as first line therapy, since it is effective, safe, noninvasive and repeatable. Endoscopic techniques currently used are dilation, multiple plastic stents insertion and fully covered self-expandable metal stents. The main indication for dilation alone is primary sclerosing cholangitis related strictures. In the vast majority of the remaining cases, temporary placement of multiple plastic stents with/without dilation is considered the treatment of choice. Although this approach is effective, it requires multiple endoscopic sessions due to the short duration of stent patency. Fully covered self-expandable metal stents appear as a good alternative to plastic stents, since they have an increased radial diameter, longer stent patency, easier insertion technique and similar efficacy. Recent advances in endoscopic technique and various devices have allowed successful treatment in most cases. The development of novel endoscopic techniques and devices is still ongoing.
Collapse
|
19
|
Abstract
Many advances have been achieved in biliary stenting over the past 30 years. Endoscopic stent placement has become the primary management therapy to relieve obstruction in patients with benign or malignant biliary tract diseases. Compared with plastic stents, a self-expandable metallic stent (SEMS) has been used for management in patients with malignant strictures because of a larger lumen and longer stent patency. Recently, SEMS has been used for various benign biliary strictures and leaks. In this article, we briefly review the characteristics of SEMS as well as complications of stent placement. We review the current guidelines for managing malignant and benign biliary obstructions. Recent developments in biliary stenting are also discussed.
Collapse
Affiliation(s)
- Hyeong Seok Nam
- Department of Internal Medicine, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Dae Hwan Kang
- Department of Internal Medicine, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| |
Collapse
|
20
|
Imamine R, Shibata T, Yabuta M, Shinozuka K, Kataoka M, Isoda H, Yoshizawa A, Uemoto S, Togashi K. Long-Term Outcome of Percutaneous Biliary Interventions for Biliary Anastomotic Stricture in Pediatric Patients after Living Donor Liver Transplantation with Roux-en-Y Hepaticojejunostomy. J Vasc Interv Radiol 2015; 26:1852-9. [DOI: 10.1016/j.jvir.2015.07.029] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 07/30/2015] [Accepted: 07/31/2015] [Indexed: 02/07/2023] Open
|
21
|
Biliary stent migration: a brief review of potential complications and possible etiological factors. Am J Ther 2015; 21:e124-9. [PMID: 23508199 DOI: 10.1097/mjt.0b013e3182491dd9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Biliary endoprostheses continue to demonstrate their utility and simplicity in daily therapeutic endoscopy. However, the transient nature of these foreign bodies also underscores their potential detrimental effects even after successful deployment. Stent related factors, such as type, length and caliber offer potential avenues to minimize the risk of migration. However, a patient related factor such as the presence of prior abdominal surgeries makes it paramount for endoscopists to ascertain the location of a migrated stent. There is a ripe niche for continued research and development in biodegradable stents.
Collapse
|
22
|
Moy BT, Birk JW. An Update to Hepatobiliary Stents. J Clin Transl Hepatol 2015; 3:67-77. [PMID: 26357636 PMCID: PMC4542081 DOI: 10.14218/jcth.2015.00040] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Revised: 01/31/2015] [Accepted: 02/05/2015] [Indexed: 12/14/2022] Open
Abstract
Endoscopic stent placement is a common primary management therapy for benign and malignant biliary strictures. However, continuous use of stents is limited by occlusion and migration. Stent technology has evolved significantly over the past two decades to reduce these problems. The purpose of this article is to review current guidelines in managing malignant and benign biliary obstructions, current endoscopic techniques for stent placement, and emerging stent technology. What began as a simple plastic stent technology has evolved significantly to include uncovered, partially covered, and fully covered self-expanding metal stents (SEMS) as well as magnetic, bioabsorbable, drug-eluting, and antireflux stents.(1).
Collapse
Affiliation(s)
| | - John W. Birk
- Department of Medicine, Division of Gastroenterology-Hepatology, University of Connecticut Health Center, Farmington, CT, USA
| |
Collapse
|
23
|
Blero D, Huberty V, Devière J. Novel biliary self-expanding metal stents: indications and applications. Expert Rev Gastroenterol Hepatol 2015; 9:359-67. [PMID: 25231201 DOI: 10.1586/17474124.2015.960395] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.
Collapse
Affiliation(s)
- Daniel Blero
- CHU Charleroi et Vésale, ISPPC, Université Libre de Bruxelles, 1 boulevard Zoé Drion, 6000 Charleroi, Belgium
| | | | | |
Collapse
|
24
|
Grolich T, Crha M, Novotný L, Kala Z, Hep A, Nečas A, Hlavsa J, Mitáš L, Misík J. Self-expandable biodegradable biliary stents in porcine model. J Surg Res 2014; 193:606-12. [PMID: 25201575 DOI: 10.1016/j.jss.2014.08.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 07/18/2014] [Accepted: 08/05/2014] [Indexed: 12/19/2022]
Abstract
BACKGROUND Treatment or prevention of a benign biliary tree stricture is an unresolved problem. A novel self-expandable biodegradable polydioxanon biliary stent in a porcine model was studied. MATERIALS AND METHODS This new stent was used in 23 pigs. Feasibility and safety of surgical stenting, time of biodegradation, and histologic reaction in 2, 8, 13, and 20 wk of a follow-up were studied. All stents were inserted into a common bile duct through a duodenal papilla following small dilatation. After surgical evaluation of abdominal cavities, the pigs were sacrificed to remove common bile ducts with the stents. All bile ducts were assessed by macroscopic and histopathologic examination. RESULTS Self-expansion was correct in all cases. Neither bile duct obstruction nor postsurgical complications were observed. Macroscopic evaluation indicated lightening of the stent color in 2 wk, a partial disintegration in 8 wk, and a complete absorption in 13 and 20 wk. Histologic evaluation in general substantiated a mild-to-moderate inflammatory reaction in the lamina propria during the whole follow up and had no clinical consequences. No cholangitis, necrosis, abscess, or excessive fibroplasia was found in a hepatoduodenal ligament. CONCLUSIONS Our results suggest that polydioxanon biodegradable self-expanding stents seem to be useful for biliary system implantation, offer a good biocompatibility, and completely degrade within 13 wk.
Collapse
Affiliation(s)
- Tomáš Grolich
- Department of Surgery, Masaryk University, Brno, Czech Republic.
| | - Michal Crha
- CEITEC - Central European Institute of Technology, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic
| | - Ladislav Novotný
- Institute of Pathology and Parasitology, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic; Finn Pathologists, Department of histology, Weybread, United Kingdom
| | - Zdeněk Kala
- Department of Surgery, Masaryk University, Brno, Czech Republic
| | - Aleš Hep
- Department of Hepatogastroenterology, Masaryk University, Brno, Czech Republic
| | - Alois Nečas
- CEITEC - Central European Institute of Technology, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic
| | - Jan Hlavsa
- Department of Surgery, Masaryk University, Brno, Czech Republic
| | - Ladislav Mitáš
- Department of Surgery, Masaryk University, Brno, Czech Republic
| | - Jan Misík
- Faculty of Military Health Sciences, Department of Toxicology, University of Defence, Hradec Kralove, Czech Republic
| |
Collapse
|
25
|
Park JH, Song HY, Shin JH, Kim JH, Jun EJ, Cho YC, Kim SH, Park J. Polydioxanone biodegradable stent placement in a canine urethral model: analysis of inflammatory reaction and biodegradation. J Vasc Interv Radiol 2014; 25:1257-1264.e1. [PMID: 24912878 DOI: 10.1016/j.jvir.2014.03.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Revised: 03/20/2014] [Accepted: 03/21/2014] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To investigate the inflammatory reaction and perform quantitative analysis of biodegradation after placement of a polydioxanone (PDO) biodegradable stent in a canine urethral model. MATERIALS AND METHODS PDO biodegradable stents were placed in the proximal and distal urethra of nine male mongrel dogs. The dogs were euthanized 4 weeks (group A; n = 3), 8 weeks (group B; n = 3), or 12 weeks (group C; n = 3) after stent placement. The luminal diameter of the stent-implanted urethra was assessed by follow-up retrograde urethrography, and histologic findings were obtained after the dogs were killed. Stents were removed after euthanasia, and their surface morphology and molecular weight were evaluated. Hematologic examination was performed to evaluate inflammatory reaction. RESULTS Stent placement was technically successful in all dogs. The average luminal diameter gradually decreased. The average number of epithelial layers (2.93 vs 4.42; P < .001), the average thickness of papillary projection (0.80 mm vs 1.28 mm; P < .001), and the average thickness of submucosal fibrosis (0.34 mm vs 0.49 mm ; P < .001) were significantly increased in group B versus group A. There were no significant differences between group B and group C. The average inflammatory cell infiltration did not differ significantly in the three groups. Molecular weight losses were 54% in group A and 84% in group B. In group C, PDO stents were completely decomposed. CONCLUSIONS An experimental study in a canine urethral model has demonstrated acceptable inflammatory reaction with gradually increasing granulation tissue but no luminal obstruction within 12 weeks.
Collapse
Affiliation(s)
- Jung-Hoon Park
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| | - Ho-Young Song
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea.
| | - Ji Hoon Shin
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| | - Jin Hyoung Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| | - Eun Jung Jun
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| | - Young Chul Cho
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| | - Soo Hwan Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| | - Jihong Park
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul 138-736, Republic of Korea
| |
Collapse
|
26
|
Chen Y, Yan J, Zhao C, Zhang S, Yu S, Wang Z, Wang X, Zhang X, Zheng Q. In vitro and in vivo assessment of the biocompatibility of an Mg-6Z(n) alloy in the bile. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2014; 25:471-480. [PMID: 24243223 DOI: 10.1007/s10856-013-5090-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2013] [Accepted: 11/05/2013] [Indexed: 06/02/2023]
Abstract
There is a great clinical need for biodegradable bile duct stents. Biodegradable stents made of an Mg-6Zn alloy were investigated in both vivo animal experiment and in vitro cell experiments. During the in vivo experiments, blood biochemical tests were performed to determine serum magnesium, serum creatinine (CREA), blood urea nitro-gen (BUN), serum lipase (LPS), total bilirubin (TB) and glutamic-pyruvic transaminase (GPT) levels. Moreover, tissue samples of common bile duct (CBD), liver and kidney were taken for histological evaluation. In the in vitro experiments, primary mouse extrahepatic bile duct epithelial cells (MEBDECs) were isolated and cultured. Cytotoxicity testing was carried out using the MTT method. Flow cytometry analyses with propidium iodide staining were performed to evaluate the effect of Mg-6Zn alloy extracts on cell cycle. The in vivo experiments revealed no significant differences (P > 0.05) in serum magnesium, CREA, BUN, LPS, TB or GPT before and after the operation. Based on the HE results, hepatocytes, bile duct epithelial cells, renal glomerulus and renal tubule tissues did not present significant necrosis. In the in vitro experiments, the cell relative growth rate curve did not change significantly from 20 to 40 % extracts. In vitro experiments showed that 20-40 % Mg-6Zn extracts are bio-safe for MEBDECs. In vivo experiments showed that Mg-6Zn stents did not affect several important bio-chemical parameters or, harm the function or morphology of the CBD, kidney, pancreas and liver. Our data suggested that this Mg-6Zn alloy is a safe biocompatible material for CBD.
Collapse
Affiliation(s)
- Yigang Chen
- Department of General Surgery, Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Mauri G, Michelozzi C, Melchiorre F, Poretti D, Tramarin M, Pedicini V, Solbiati L, Cornalba G, Sconfienza LM. Biodegradable biliary stent implantation in the treatment of benign bilioplastic-refractory biliary strictures: preliminary experience. Eur Radiol 2013; 23:3304-3310. [PMID: 23842947 DOI: 10.1007/s00330-013-2947-2] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 05/25/2013] [Accepted: 05/28/2013] [Indexed: 01/31/2023]
Abstract
OBJECTIVES To evaluate feasibility, safety, and outcome of patients treated with biodegradable biliary stents for benign biliary stenosis refractory to other treatments. METHODS Between March 2011 and September 2012, ten patients (seven men, three women; age 59 ± 7 years) with recurrent cholangitis due to postsurgical biliary stricture, previous multiple unsuccessful (two to five) bilioplasties, and unsuitability for surgical/endoscopic repair underwent percutaneous implantation of a biodegradable biliary stent. Patients were followed-up clinically and with ultrasound at 1, 3 and 6 months, and then at 6-month intervals. RESULTS Stent implantation was always feasible. No immediate major or minor complications occurred. In all patients, 48-h cholangiographic control demonstrated optimal stent positioning and stenosis resolution. In a median follow-up time of 16.5 months (25th-75th percentiles = 11-20.25 months) no further invasive treatment was needed. Three patients experienced transient episodes of cholangitis. Neither re-stenosis nor dilatation of the biliary tree was documented during follow-up. No stent was visible at the 6-month follow-up. CONCLUSIONS Percutaneous placement of biodegradable biliary stents represents a new option in treating benign biliary stenoses refractory to treatment with bilioplasty. This technique seems to be feasible, effective and free from major complications. Further investigations are warranted to confirm our preliminary results.
Collapse
Affiliation(s)
- Giovanni Mauri
- Servizio di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese, Milano, Italy,
| | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Familiari P, Boškoski I, Bove V, Costamagna G. ERCP for biliary strictures associated with chronic pancreatitis. Gastrointest Endosc Clin N Am 2013; 23:833-45. [PMID: 24079793 DOI: 10.1016/j.giec.2013.06.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Chronic pancreatitis (CP)-related common bile duct (CBD) strictures are more difficult to treat endoscopically compared with benign biliary strictures because of their nature, particularly in patients with calcific CP. Before any attempt at treatment, malignancy must be excluded. Single plastic stents can be used for immediate symptom relief and as "bridge to surgery and/or bridge to decision," but are not suitable for definitive treatment of CP-related CBD strictures because of long-term poor results. Temporary simultaneous placement of multiple plastic stents has a high technical success rate and provides good long-term results.
Collapse
Affiliation(s)
- Pietro Familiari
- Digestive Endoscopy Unit, Gemelli University Hospital, Università Cattolica del Sacro Cuore, Rome 00167, Italy
| | | | | | | |
Collapse
|
29
|
Kwon CI, Ko KH, Hahm KB, Kang DH. Functional self-expandable metal stents in biliary obstruction. Clin Endosc 2013; 46:515-21. [PMID: 24143314 PMCID: PMC3797937 DOI: 10.5946/ce.2013.46.5.515] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 06/28/2013] [Accepted: 06/29/2013] [Indexed: 12/20/2022] Open
Abstract
Biliary stents are widely used not only for palliative treatment of malignant biliary obstruction but also for benign biliary diseases. Each plastic stent or self-expandable metal stent (SEMS) has its own advantages, and a proper stent should be selected carefully for individual condition. To compensate and overcome several drawbacks of SEMS, functional self-expandable metal stent (FSEMS) has been developed with much progress so far. This article looks into the outcomes and defects of each stent type for benign biliary stricture and describes newly introduced FSEMSs according to their functional categories.
Collapse
Affiliation(s)
- Chang-Il Kwon
- Digestive Disease Center, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| | | | | | | |
Collapse
|
30
|
Abstract
Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.
Collapse
Affiliation(s)
- Clark D Hair
- Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA
| | | |
Collapse
|
31
|
Mizandari M, Pai M, Xi F, Valek V, Tomas A, Quaretti P, Golfieri R, Mosconi C, Guokun A, Kyriakides C, Dickinson R, Nicholls J, Habib N. Percutaneous intraductal radiofrequency ablation is a safe treatment for malignant biliary obstruction: feasibility and early results. Cardiovasc Intervent Radiol 2012; 36:814-9. [PMID: 23232859 DOI: 10.1007/s00270-012-0529-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Accepted: 11/03/2012] [Indexed: 02/06/2023]
Abstract
PURPOSE Previous clinical studies have shown the safety and efficacy of this novel radiofrequency ablation catheter when used for endoscopic palliative procedures. We report a retrospective study with the results of first in man percutaneous intraductal radiofrequency ablation in patients with malignant biliary obstruction. METHODS Thirty-nine patients with inoperable malignant biliary obstruction were included. These patients underwent intraductal biliary radiofrequency ablation of their malignant biliary strictures following external biliary decompression with an internal-external biliary drainage. Following ablation, they had a metal stent inserted. RESULTS Following this intervention, there were no 30-day mortality, hemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the 39 patients, 28 are alive and 10 patients are dead with a median survival of 89.5 (range 14-260) days and median stent patency of 84.5 (range 14-260) days. One patient was lost to follow-up. All but one patient had their stent patent at the time of last follow-up or death. One patient with stent blockage at 42 days postprocedure underwent percutaneous transhepatic drain insertion and restenting. Among the patients who are alive (n = 28) the median stent patency was 92 (range 14-260) days, whereas the patients who died (n = 10) had a median stent patency of 62.5 (range 38-210) days. CONCLUSIONS In this group of patients, it appears that this new approach is feasible and safe. Efficacy remains to be proven in future, randomized, prospective studies.
Collapse
Affiliation(s)
- Malkhaz Mizandari
- Department of Radiology, Tbilisi State Medical University, Tbilisi, Georgia
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Tokar JL, Banerjee S, Barth BA, Desilets DJ, Kaul V, Kethi SR, Pedrosa MC, Pfau PR, Pleskow DK, Varadarajulu S, Wang A, Song LMWK, Rodriguez SA. Drug-eluting/biodegradable stents. Gastrointest Endosc 2011; 74:954-8. [PMID: 21944310 DOI: 10.1016/j.gie.2011.07.028] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2011] [Accepted: 07/18/2011] [Indexed: 02/08/2023]
|