Table 1 Studies describing detection of hepatitis B virus from samples other than serum or whole blood
Ref.Year of publicationSample usedMethod usedComments
Mendy et al[13]2005Dried blood spots along with serumHBsAg detected by determine (TM) HBsAgComparison of DBS results with serum testing results: Sn 96%, Sp 100%
Chen et al[21]2005Ovarian tissueHBsAg and HBcAg detected by immunocytochemistry and HBV DNA by PCRPositivity rate of HBV DNA was 58.3%
van der Laan et al[17]2007HepatocytesFlow cytometric quantitationA significant correlation was found between the percentage of infected hepatocytes and the intracellular expression level of HBsAg (R = 0.841, P < 0.001)
Goh et al[22]2008Cerumen and otorrhoea samples along with serumHBsAg and HBeAg were detected by Enzyme Immunoassay and HBV DNA was detected by quantitative PCRHBV DNA was detected in 66.7% of cerumen samples and 100% of otorrhoea samples
Chen et al[25]2009Parotid tissueSerological markers by immunocytrochemistry and HBV DNA by PCROverall positivity rate was 54.5% to 58.3%
Nuriya et al[18]2010HepatocyresPCR - In situ hybridisationAll hepatocytes were infected with HBV in chronic liver disease
Villar et al[14]2011Dried blood spotsHBsAg, anti-HBc, and anti-HBs were detected by ELISASn was 90.5%, 97.6%, and 78% for anti-HBc, HBsAg, anti-HBs assays, and Sp was 92.6%, 96.7%, and 97.3% for anti-HBc, HBsAg, and anti-HBs assays, respectively
Wu et al[29]2012Paraffin embedded intrahepatic and extrahepaticcholangiocarcinoma tissueHBV DNA by nested PCR and HBV related antigens by immunohistochemistry methodHBV DNA and HBV antigens were detected significantly in cases of intrahepatic cholangiocarcinoma
Arora et al[24]2012SalivaHBsAg was detected by ELISASn 74.29% and Sp 100%
Cobo et al[27]2012Spent culture media and liquid nitrogen samples of oocytes and embryosReverse transcriptase PCRViral sequences were not detected in these samples from seropositive patients
Ye et al[28]2013Discarded test tube embryos from mothers with chronic HBV infection undergoing in vitro fertilization treatmentSingle cell reverse transcriptase PCRDetection rate was 13.2%
Eftekharian et al[23]2013Cerumen along with serumHBV DNA was detected by PCRHBV DNA was detected in 6.6% of HBsAg positive patients
Kong et al[26]2013Frozen renal tissueHBsAg and HBcAg detected by immunohistochemistryFound positive in 9 out of 500 patients of glomerulonephritis without serological evidence
Ross et al[15]2013Dried blood spotsHBsAG, anti HBcAg, anti HBsAg detected by Abbott Architect and HBV DNA by artus HBV LC PCRSensitivity was 98.6%, 97.1%, 97.5%, 93%
Alidjinou et al[16]2014Dried plasma spotsHBsAg and HBV DNA detected by ELISA and PCRSn and Sp 100% for serological markers and Sn 96%, Sp 100% for HBV DNA
Zhong et al[19]2014HepatocytesCovalently closed circular HBV DNA detected by in situ PCRHelps to detect recurrence of HBV
Huang et al[20]2015Formalin fixed paraffin embedded hepatocellular carcinoma tissueDroplet digital PCR to detect HBV copy numberHighly sensitive method
Table 2 Studies describing different quantitative molecular methods
Ref.Year of publicationMethod of quantitationDetection limit
Garson et al[58]2005FRET based real time PCR assaySn at 95% detection level was 24.2 IU/mL
Welzel et al[59]2006Novel real time PCRSn at 95% detection level was 56 IU/mL
Mazet-Wagner et al[60]2006Real time PCR assay to detect total HBV DNA and cccDNA from serum and peripheral blood mononuclear cells27 IU/mL
McCormick et al[61]2006Procleix Ultrio Assay (Multiplex PCR) to detect HIV 1, HCV RNA and HBV DNA simultaneouslySp ≥ 99.5%, Sn is > 95% with detection limit for HBV DNA of 15 IU/mL
Cai et al[62]2008Real time fluorogenic Loop Mediated Isothermal Amplification (RtF-LAMP)At 95% detection level 210 copies/mL
Paraskevis et al[63]2010New ultrasensitive in house real time PCR assaySn at 95% and 50% detection level: 22.2 IU/mL and 8.4 IU/mL
Chevaliez et al[64]2010v2.0 of the CAP/CTM assayHighly Sn, could even detect 6.25 IU/mL HBV DNA; Sp is 99%, Intra-assay and interassay coefficients of variation ranged from 0.21% to 2.67% and from 0.65% to 2.25%, respectively
Sun et al[65]2011Duplex real-time PCR assay using two sets of primers/probes and a specific armored DNA as internal controlDetection limit 29.5 IU/mL; Sp 100%
Cha et al[66]2013ExiStation HBV diagnostic system9.55 IU/mL
Yang et al[67]2014Colorimetric PCR with DNA zyme containing probeBroad range of linearity and high sensitivity
Kania et al[68]20142 in house real time PCR targeting X (qPCR1) or S (qPCR2) genesqPCR1: 104 IU/mL; qPCR2: 91 IU/mL
Table 3 Comparison of different methods
Ref.Year of publicationComparison betweenRemarks
Hochberger et al[75]2006Automated COBAS AmpliPrep/COBAS TaqMan system (real time PCR) and Versant HBV 3.0Good correlation between two
Juman Awadh et al[76]2008Versant HBV 3.0 (Bayer, branched DNA mediated assay) and Biotitre B (real time PCR variant)Both were highly specific, though reproducibility of Versant HBV 3.0 was higher
Yang et al[77]2009Real Art HBV PCR Kit (Abbott, real time PCR) and Versant bDNA 3.0Abbott's kit was more sn, detection limit 27 IU/mL
Louisirirotchanakul et al[78]2010fully automated ElecsysHBsAg II assay, Architect, AxSYM and Advia Centaur HBsAg assaysThe later 2 tests appeared less sensitive in detecting early HBV infection
Berger et al[79]2010CAP/CTM assay v2.0 and v1.0Comparable results for all 278 tested samples
Lunel-Fabiani et al[80]2010Access immunoassay system from Beckman coulter with Abbott AxSYM and PRISM HBsAg assays; VIDAS was used to conclude discrepant resultsSn: 100%, Sp: 99.96%
Caliendo et al[81]2011Abbott RealTime HBV IUO, the Roche CAP/CTM HBV test, the Roche CobasTaqMan HBV test with HighPure system, and the Qiagen artus HBV TM ASRLimit of detection of artus 1.5 log(10) IU/mL, of other 3 tests 1.0 log(10) IU/mL
Ismail et al[82]2011Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP)Lower limit of detection against WHO standards were 1.43, 82 and 9 IU/mL respectively
Yeh et al[83]2014Abbott real time HBV (RealTime assay) and CAP/CTM HBV assays 2.0 (TaqMan assay)Real time assay's Sn: 98.2%, Sp: 100%. Good level of agreement between the two