BPG is committed to discovery and dissemination of knowledge
Minireviews
Copyright: ©Author(s) 2026.
World J Hepatol. Nov 27, 2026; 18(11): 125990
Published online Nov 27, 2026. doi: 10.4254/wjh.125990
Table 1 Standard-care comparators (not relabelled as artificial intelligence)
Comparator
Target or role
Design/evidence
Principal boundary
FIB-4First-line exclusion/triage for advanced fibrosisGuideline-embedded fixed clinical indexAge, prevalence and clinical context affect interpretation[16-18,24]
VCTE, ELF and MRESecond-line fibrosis assessmentEstablished non-invasive testsAvailability, technical failure and platform thresholds limit transport[16,17,26-28]
FASTEnrichment for activity plus ≥ F2 fibrosisProspective derivation and global validationPPV varied and 0.35/0.67 are study-defined anchors[29]
MEFIBMRE plus FIB-4 treatment-candidate enrichmentValidated fixed indexRequires MRE and is not machine learning[30]
MASTMRI-PDFF, MRE and AST enrichmentValidated fixed indexImaging access and threshold transport are limiting[31]
NIS4Blood-panel enrichment for at-risk NASH/MASHProspective derivation/global validationAssay access, prevalence and calibration affect PPV[32]
Table 2 ACTION criteria and minimum evidence required at each decision point
ACTION criterion
Population case finding
Non-invasive enrichment and biopsy stewardship
Imaging and longitudinal assessment
Digital pathology and trial endpoints
Minimum reportable evidence
Attached actionFlag triggers FIB-4 laboratory completion or chart reviewState second-line test referral criterion or shared biopsy discussionState repeat imaging established test or clinician reassessmentPathologist accepts/rejects score requests QC or initiates adjudicationNamed action eligible population timing completion rate and action rate
Calibration in contextCalibrate in deployment health system and denominatorCalibrate separately for primary care diabetes hepatology and biopsy cohortsValidate across scanner protocol operator and time pointValidate across stain scanner site trial and pathologist configurationCalibration plot/intercept/slope; external site/time/device validation; missingness
Threshold-specific benefitPrespecify acceptable missed advanced fibrosis and alert burdenReport net benefit false reassurance tests per actionable case and missed F2-F3Prespecify change prompting reassessment and analyse discordant trajectoriesPrespecify inclusion exclusion response or adjudication thresholds and error costsSensitivity specificity PPV/NPV decision-curve net benefit workload and missed-case rate
IntegrationDefine recipient queue turnaround and closureEmbed within contemporary FIB-4-first pathway and available referral capacityDefine acquisition QC report integration and longitudinal comparisonLock specimen scan AI review override and endpoint releaseWorkflow failure handling time-to-action adoption override capacity and delay
OversightIdentify service accountable for reviewing and closing flagsIdentify clinician responsible for escalation and biopsy decisionsKeep reassessment and treatment clinician-ledReview complete slide and AI output; pathologist issues final scoreNamed accountable role override authority discordance policy and audit trail
Non-discrimination and monitoringCompare missingness flags completion and false negatives across groupsCompare calibration access referral and missed disease across groupsMonitor device/site performance access and temporal driftMonitor site stain scanner specimen reader subgroup and version driftSubgroup metrics access-to-action drift triggers recalibration and incident response
Table 3 Evidence matrix of artificial intelligence and computational language-processing applications across the therapeutic metabolic dysfunction-associated steatohepatitis pathway - artificial intelligence and computational language-processing applications
AI modality
Target or role
Design
Comparator/reference
Calibration
Attached action
Maturity
Principal boundary
Explainable Extreme Gradient BoostingFAST ≥ 0.35 labelRetrospective NHANES development/internal testingFAST and conventional scores in the same sampleInherited FAST threshold; biopsy-disease calibration not establishedResearch triage for confirmatory testingM1Target was a FAST-defined surrogate rather than biopsy-confirmed at-risk MASH[37]
B-mode ultrasound neural networkLiver-stiffness risk categoryRetrospective 205-patient 636-image studySame-day liver stiffness clinical variables and FIB-4No clinical calibration reportedPrompt elastography or fibrosis assessmentM1Image increment was modest and target was not biopsy-confirmed fibrosis[47]
CT-to-MRI-PDFF deep learningOpportunistic steatosis categorisationProof-of-concept selected cohortMRI-PDFFNo transport calibration reportedTrigger dedicated liver assessment when appropriateM1Does not replace validated MRI-PDFF or histology[46]
Combi-elastography deep learningFibrosis stage in suspected MASLD/MASHRetrospective imaging-model validationElastography/histological staging in study settingImplementation calibration not establishedSupport established fibrosis assessmentM1-M2Generalisability across devices, operators and settings remains uncertain[45]
Multimodal outcome-prediction modelsLiver-related eventsRetrospective two-centre modellingClinical/biochemical variables and ultrasound featuresProspective threshold calibration not establishedResearch-only follow-up intensificationM1-M2Few events and no model-guided intervention[48]
Imaging-report NLP plus EHR rulesUncoded MASLD case findingRetrospective EHR ascertainment with manual reviewDiagnosis codes and manual reviewNo clinical calibration or action threshold reportedTrigger FIB-4 or first-line fibrosis assessmentM2Identification does not show completed assessment or improved outcomes[20]
Rule-based NLP in United States veteransImaging steatosis and MASLD ascertainmentRetrospective national cohort with chart-labelled validationChart review and diagnostic codesNo clinical action threshold reportedQueue structured fibrosis risk assessmentM2Large-scale ascertainment was not a closed-loop intervention[22]
GO-ASIA machine-learning modelsSignificant fibrosis in Asian MASLDMulticentre biopsy-based modelling and validationConventional non-invasive scores and biopsySetting-specific; transport calibration requiredSelect second-line testing or specialist reviewM2Performance is population- and prevalence-dependent[35]
Lightweight clinical-metabolomic modelMASH with F2-F3 fibrosisMulticountry development and independent testingClinical/non-invasive models and biopsyExternal calibration and local assay transport require confirmationEnrich patients for biopsy or treatment-eligibility reviewM2Selected cohorts and metabolomic availability limit implementation[36]
ALADDIN laboratory with or without VCTE modelsBiopsy-confirmed ≥ F2 fibrosisTraining internal test and nine-centre external validationVCTE, FAST and Agile-3 within the same external cohortYes; calibration and decision-curve analysis reportedEscalate to hepatology advanced imaging or biopsy discussionM2No prospective workload, missed-case or outcome benefit was measured[34]
Deep-learning ultrasound steatosis quantificationHistological steatosis gradeRetrospective training plus two histology validation cohortsHistology and conventional ultrasound assessmentThreshold performance reported; clinical calibration not establishedStandardise steatosis measurement or prompt established fibrosis work-upM2Steatosis is not equivalent to actionable MASH or fibrosis[43]
Automated whole-liver MRI segmentationMRI-PDFF quantificationTechnical training/validation with biopsy and manual-ROI subsetsManual ROI-PDFF and histologyNot applicable to treatment thresholdQuality-control and standardise PDFF reassessmentM2Technical agreement does not establish treatment-response utility[44]
AIM-MASH analytical systemTrial enrolment and histological component/endpoint scoringRetrospective clinical-trial material with repeatability and consensus comparisonExpert consensus and individual pathologistsNot applicable to probability calibrationProvide component scores and heat maps for pathologist reviewM2Deterministic repeatability is distinct from clinical-reader agreement[53]
qFibrosis repeatability/reproducibilityQuantitative fibrosis measurementMulti-instrument analytical validationRepeat scans/instruments and reference readsNot applicableQuality-controlled quantitative fibrosis scoringM2Analytical reproducibility is not clinical endpoint qualification[56]
AI/quantitative pathology trial reanalysesContinuous or spatial treatment-related histological changeSecondary analyses of phase 2/3 trial biopsiesConventional ordinal histology and paired biopsyNot applicableGenerate exploratory response endpoints and adjudication hypothesesM2Greater sensitivity does not validate a surrogate endpoint or treatment rule[57-60]
AIM-MASH assisted-reader workflowMASH activity resolution and fibrosis trial endpointsMultisite assisted-reader clinical validationUnassisted pathologist reads and expert referenceReader-performance endpoints rather than risk calibrationPathologist accepts or rejects AI-assisted trial scoresM3Does not establish autonomous diagnosis or unrestricted treatment selection[53]
SHG/TPEF qFibrosis assistanceFibrosis-based trial inclusion, exclusion and responseRandomised crossover reader study of 120 slides and four pathologistsUnassisted reads and expert assessmentNot applicableSupport human trial-eligibility and response assessmentM3Reader- and platform-specific with no patient-outcome benefit[55]
SHG-assisted pathologist decision studyFibrosis score acceptance/overrideFour-reader assistance study of 120 casesPre-assistance vs post-assistance readsNot applicableRequire documented acceptance, override and discordance reviewM3Assistance reduced some discrepancies but increased others[61]
Qualified AIM-NASH drug-development toolPhase 2/3 MASH-trial enrolment and histology endpointsEMA and FDA qualification in a specified human-reviewed workflowDefined regulatory context of useLocked/version-controlled contextCentral pathologist accepts or rejects each scoreM4RLimited to stated trial workflow and does not correct biopsy sampling error[62,63]
Table 4 Implementation and regulatory checklist for an actionable metabolic dysfunction-associated steatohepatitis artificial intelligence system
Checklist domain
Minimum specification before use
Evidence or documentation
Accountable owner
Failure response
Intended context of useDefine population setting task user output and excluded usesApproved context-of-use statement and workflow mapClinical service lead and governance committeeSuspend use outside scope and require separate validation
Model identity and lockRecord model name architecture class version parameters and release dateVersion manifest checksum and change logVendor/developer and institutional model ownerRevert to last validated version or suspend deployment
Local validation and calibrationValidate discrimination and calibration in intended denominatorLocal validation report with thresholds subgroup results and uncertaintyClinical AI/biostatistics leadRecalibrate alter threshold or reject deployment
Data and missingness controlsSpecify variables units timing allowable missingness and imputationData dictionary lineage record and missingness dashboardData stewardWithhold output or route to manual review
Threshold and attached actionLink every threshold to one predefined action and accountable userSigned decision table with PPV/NPV net benefit and capacity estimateClinical pathway ownerDisable action if performance or capacity is unacceptable
Workflow integrationDefine destination turnaround acknowledgement closure and escalationStandard operating procedure and user-acceptance testingOperational service ownerEscalate unclosed outputs and pause if closure falls below target
Specimen stain scanner and platform requirementsSpecify adequacy stain scanner magnification file format and QC or imaging device/protocolPlatform compatibility matrix and QC logsLaboratory/pathology or radiology leadReject rescan/reacquire or use conventional assessment
Human review and overrideDefine inspection acceptance override and recordingTraining record interface specification and override logFinal responsible clinician or pathologistMandatory manual review/adjudication; never auto-release outside qualification
Audit trail and traceabilityPreserve inputs version output user action override time and final decisionImmutable audit log with retention policyInformation governance leadIncident investigation and case recall if incomplete
Subgroup and equity monitoringMonitor calibration false negatives action completion and accessPeriodic equity dashboard with confidence intervalsClinical governance/equity leadInvestigate recalibrate redesign access or suspend affected use
Drift and update policyMonitor input prevalence calibration device/stain and outcome driftDrift dashboard alert thresholds and revalidation protocolModel lifecycle ownerFreeze retrain/recalibrate and revalidate before release
Safety incident and cybersecurity managementDefine error reporting downtime rollback access control and security safeguardsRisk register continuity plan and incident logPatient-safety and security leadsSwitch to conventional workflow and notify as required
Regulatory status and claimsDistinguish research local decision support medical device and DDT qualificationCurrent official regulatory record and approved claimsRegulatory affairs leadRemove unsupported claims and prohibit extrapolation
Outcome and value monitoringMeasure effect of attached action on intended process or outcomeProspective completion yield missed-case delay workload and outcome dataClinical service and trial sponsorModify or discontinue if benefit is absent or harm/cost unacceptable