Brief Article
Copyright ©2013 Baishideng Publishing Group Co.
World J Gastroenterol. Sep 14, 2013; 19(34): 5732-5737
Published online Sep 14, 2013. doi: 10.3748/wjg.v19.i34.5732
Table 1 Comparison of different long diameters of lymph nodes displayed, degrees of lymph node enhancement displayed and ratios of short diameter to long diameter of lymph nodes displayed by multi-slice spiral computed tomography and postoperative pathological results for determination of lymph node metastasis
Number of lymph nodes detected by MSCTK valueSensitivitySpecificity
Diameter of lymph nodes≥ 5 mm4700.46488.5%60.1%
≥ 8 mm3170.83179.6%78.8%
≥ 10 mm1280.23248.6%93.5%
Difference of enhancement of lymph nodes≥ 40 Hu4950.39789.3%65.5%
≥ 80 Hu3790.84981.6%75.6%
≥ 100 Hu1970.33553.8%95.5%
Ratio of short diameter to long diameter of lymph nodes≥ 0.54470.51394.3%57.3%
≥ 0.73750.87385.6%71.8%
Table 2 Comparison of sensitivities and specificities of metastatic lymph nodes in different groups displayed by multi-slice spiral computed tomography
Positions of lymph nodesSpecificitySensitivity
Right area of cardiac orifice79.2%57.8%
Left area of cardiac orifice81.3%73.5%
Lesser curvature79.6%90.3%
Greater curvature87.5%45.0%
Superior area of pylorus88.1%76.7%
Inferior area of pylorus78.0%81.9%
Adjacent to left gastric artery, common hepatic artery, and arteria coeliaca83.2%89.4%