Rapid Communication
Copyright ©2007 Baishideng Publishing Group Co.
World J Gastroenterol. Aug 21, 2007; 13(31): 4260-4263
Published online Aug 21, 2007. doi: 10.3748/wjg.v13.i31.4260
Table 1 Oligonucleotide chip, real-time PCR, and sequencing in detection of genotypes B and C in mixed samples
Oligonucleotide chipReal-time PCRSequencingPercentage
B and CB and CB and C50
B and CB and CC10
B and CB and CC1
CB and CC0.1
Table 2 Comparison of oligonucleotide chip, real-time PCR, and sequencing for detection of the clinical samples n (%)
GenotypesOligonucleotide chipReal-time PCRSequencing
B41 (33)41 (33)45 (36)
C76 (60)76 (60)81 (64)
Mixture of B and C9 (7)9 (7)0