1
|
He X, Shen Y, Feng Y, Gao Z, Xue H, Chen H. Latest possible timing for endoscopic-assisted intervention in capsule endoscopy. Gastroenterol Rep (Oxf) 2025; 13:goaf011. [PMID: 40161976 PMCID: PMC11954545 DOI: 10.1093/gastro/goaf011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 06/26/2024] [Accepted: 10/29/2024] [Indexed: 04/02/2025] Open
Abstract
Background Delayed upper gastrointestinal transit during small bowel capsule endoscopy (SBCE) can lead to incomplete or failed examinations but can be treated by endoscopic-assisted intervention (EAI). The aim of this study was to investigate the latest possible timing of EAI. Methods Patients who underwent SBCE and received EAI between July 2007 and December 2020 were retrospectively reviewed. A novel T-value was developed that accounted for the varied battery life of different generations of PillCam when determining the latest possible timing of EAI, where T is calculated as EAI time/[minimum battery life of the PillCam minus small bowel transit time (6 h)] × 100%. Patients were divided into two groups based on the cut-off value of the receiver operating characteristic curve: early EAI (group A, T < 76.3%) and late EAI (group B, T ≥ 76.3%). The primary outcome was the completion rate (CR), and the secondary outcome was the detection rate. The latest possible timing of EAI (h) was calculated according to the T-value formula and further verified in our recent data set. Results This study included 108 patients. The CR was significantly higher in group A than in group B (79.2% vs 58.2%; P = 0.018). Late EAI was an independent predictor of incomplete SBCE (odds ratio = 2.900; 95% confidence interval, 1.193-7.053). The latest possible timing of EAI was 1.5 h and 4.6 h from the start of the examination for PillCam SB1 and PillCam SB2/3, respectively. Conclusions Early EAI was associated with higher CR. The latest possible timing of EAI was 1.5 h for PillCam SB1 and 4.6 h for PillCam SB2/3 from the start of the examination.
Collapse
Affiliation(s)
- Xinlong He
- Division of Gastroenterology and Hepatology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China
| | - Yufeng Shen
- Division of Gastroenterology and Hepatology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China
| | - Ye Feng
- Division of Gastroenterology and Hepatology, Kunshan Second People’s Hospital, Suzhou, Jiangsu, P. R. China
| | - Zhifang Gao
- Division of Gastroenterology and Hepatology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China
| | - Hanbing Xue
- NHC Key Laboratory of Digestive Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China
| | - Huimin Chen
- Division of Gastroenterology and Hepatology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China
| |
Collapse
|
2
|
He XL, Chen HM, Xue HB. Risk factors of delayed upper gastrointestinal transit in capsule endoscopy. Scand J Gastroenterol 2024; 59:1216-1219. [PMID: 39230211 DOI: 10.1080/00365521.2024.2399670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 08/05/2024] [Accepted: 08/27/2024] [Indexed: 09/05/2024]
Abstract
OBJECTIVE The purpose was to investigate the risk factors for delayed upper gastrointestinal transit (DUGT) in small bowel capsule endoscopy (SBCE) and to improve the efficacy of SBCE. METHODS The medical records of patients who underwent SBCE in Renji hospital between January 2015 and January 2023 were retrospectively reviewed. Data collection included patient demographics and potential risk factors for DUGT such as indications for the examination, underlying diseases, hospitalization status, anemia, inflammation. Risk factors were analyzed using univariable and multivariable logistic regression models. DUGT was defined as failure of a capsule to pass through the pylorus within 1 h. RESULTS A total of 1459 patients who underwent SBCE were included in the study. 306 Cases (21%) experienced DUGT and all received conservative observation, medication treatment, endoscopic intervention, and other measures based on specific circumstances. The overall completion rate (CR) of the examination was 95.5% (1394/1459). Logistic regression analysis showed that hospitalization status (p = 0.030), diarrhea (p = 0.017), diabetes (p = 0.027) and cerebrovascular disease (p = 0.038) were significant risk factors for DUGT. CONCLUSIONS In our study, DUGT of SBCE was associated with hospitalization status, diarrhea, diabetes and cerebrovascular disease. Therefore, for the patients with the above risk factors, we should closely check the capsule status during the examination process, in order to take appropriate intervention measures as soon as possible.
Collapse
Affiliation(s)
- Xin Long He
- Division of Gastroenterology and Hepatology, NHC Key Laboratory of Digestive Diseases, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Hui Min Chen
- Division of Gastroenterology and Hepatology, NHC Key Laboratory of Digestive Diseases, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Han Bing Xue
- Division of Gastroenterology and Hepatology, NHC Key Laboratory of Digestive Diseases, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| |
Collapse
|
3
|
Nam SJ, Moon G, Park JH, Kim Y, Lim YJ, Choi HS. Deep Learning-Based Real-Time Organ Localization and Transit Time Estimation in Wireless Capsule Endoscopy. Biomedicines 2024; 12:1704. [PMID: 39200169 PMCID: PMC11351118 DOI: 10.3390/biomedicines12081704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/16/2024] [Accepted: 07/22/2024] [Indexed: 09/02/2024] Open
Abstract
BACKGROUND Wireless capsule endoscopy (WCE) has significantly advanced the diagnosis of gastrointestinal (GI) diseases by allowing for the non-invasive visualization of the entire small intestine. However, machine learning-based methods for organ classification in WCE often rely on color information, leading to decreased performance when obstacles such as food debris are present. This study proposes a novel model that integrates convolutional neural networks (CNNs) and long short-term memory (LSTM) networks to analyze multiple frames and incorporate temporal information, ensuring that it performs well even when visual information is limited. METHODS We collected data from 126 patients using PillCam™ SB3 (Medtronic, Minneapolis, MN, USA), which comprised 2,395,932 images. Our deep learning model was trained to identify organs (stomach, small intestine, and colon) using data from 44 training and 10 validation cases. We applied calibration using a Gaussian filter to enhance the accuracy of detecting organ boundaries. Additionally, we estimated the transit time of the capsule in the gastric and small intestine regions using a combination of a convolutional neural network (CNN) and a long short-term memory (LSTM) designed to be aware of the sequence information of continuous videos. Finally, we evaluated the model's performance using WCE videos from 72 patients. RESULTS Our model demonstrated high performance in organ classification, achieving an accuracy, sensitivity, and specificity of over 95% for each organ (stomach, small intestine, and colon), with an overall accuracy and F1-score of 97.1%. The Matthews Correlation Coefficient (MCC) and Geometric Mean (G-mean) were used to evaluate the model's performance on imbalanced datasets, achieving MCC values of 0.93 for the stomach, 0.91 for the small intestine, and 0.94 for the colon, and G-mean values of 0.96 for the stomach, 0.95 for the small intestine, and 0.97 for the colon. Regarding the estimation of gastric and small intestine transit times, the mean time differences between the model predictions and ground truth were 4.3 ± 9.7 min for the stomach and 24.7 ± 33.8 min for the small intestine. Notably, the model's predictions for gastric transit times were within 15 min of the ground truth for 95.8% of the test dataset (69 out of 72 cases). The proposed model shows overall superior performance compared to a model using only CNN. CONCLUSIONS The combination of CNN and LSTM proves to be both accurate and clinically effective for organ classification and transit time estimation in WCE. Our model's ability to integrate temporal information allows it to maintain high performance even in challenging conditions where color information alone is insufficient. Including MCC and G-mean metrics further validates the robustness of our approach in handling imbalanced datasets. These findings suggest that the proposed method can significantly improve the diagnostic accuracy and efficiency of WCE, making it a valuable tool in clinical practice for diagnosing and managing GI diseases.
Collapse
Affiliation(s)
- Seung-Joo Nam
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Kangwon National University School of Medicine, Chuncheon 24341, Republic of Korea
| | - Gwiseong Moon
- Ziovision Co., Ltd., Chuncheon 24341, Republic of Korea
| | | | - Yoon Kim
- Ziovision Co., Ltd., Chuncheon 24341, Republic of Korea
- Department of Computer Science and Engineering, College of IT, Kangwon National University, Chuncheon 24341, Republic of Korea
| | - Yun Jeong Lim
- Division of Gastroenterology, Department of Internal Medicine, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, 27 Dongguk-ro, Ilsandong-gu, Goyang 10326, Republic of Korea
| | - Hyun-Soo Choi
- Ziovision Co., Ltd., Chuncheon 24341, Republic of Korea
- Department of Computer Science and Engineering, Seoul National University of Science and Technology, 232, Gongneung-ro, Nowon-gu, Seoul 01811, Republic of Korea
| |
Collapse
|
4
|
Park J, Kim JS, Song JH, Nam K, Kim SE, Jeong ES, Kim JH, Jeon SR. Discordance Rate and Risk Factor of Other Diagnostic Modalities for Small Bowel Tumors Detected by Device-Assisted Enteroscopy: A Korean Association for the Study of Intestinal Disease (KASID) Multicenter Study. Gut Liver 2024; 18:686-694. [PMID: 38726559 PMCID: PMC11249927 DOI: 10.5009/gnl240030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 03/05/2024] [Accepted: 03/11/2024] [Indexed: 07/16/2024] Open
Abstract
BACKGROUND/AIMS Despite advances in imaging and endoscopic technology, diagnostic modalities for small bowel tumors are simultaneously performed. We investigated the discrepancy rate between each modality and predictive factors of discrepancy in patients with definite small bowel tumors. METHODS Data of patients with definite small bowel tumors who underwent both device-assisted enteroscopy (DAE) and computed tomography (CT) were retrieved from web-based enteroscopy registry database in Korea. Predictive risk factors associated with discrepancy were analyzed using logistic regression analysis. RESULTS Among 998 patients, 210 (21.0%) were diagnosed with small bowel tumor using DAE, in 193 patients with definite small bowel tumor, DAE and CT were performed. Of these patients, 12 (6.2%) showed discrepancy between examinations. Among 49 patients who underwent DAE and video capsule endoscopy (VCE) examination, 13 (26.5%) showed discrepancy between examinations. No significant independent risk factors were associated with concordance between DAE and CT in multivariate logistic regression analysis among the patients. In a multivariate logistic regression analysis, red blood cell transfusion was negatively associated with concordance between DAE and VCE in patients with small bowel tumor (odds ratio, 0.163; 95% confidence interval, 0.026 to 1.004; p=0.050). CONCLUSIONS For small bowel tumors, the discrepancy rate between DAE and CT was 6.2%, and 26.5% between DAE and VCE. Despite developments in cross-sectional imaging (VCE and DAE modalities), discrepancies still exist. For small bowel bleeding that require significant transfusion while showing insignificant VCE findings, DAE should be considered as the next diagnostic approach, considering the possibility of missed small bowel tumor.
Collapse
Affiliation(s)
- Jihye Park
- Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jin Su Kim
- Department of Internal Medicine, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Joo Hye Song
- Department of Internal Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Kwangwoo Nam
- Department of Gastroenterology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea
| | - Seong-Eun Kim
- Department of Internal Medicine, Ewha Womans University College of Medicine, Seoul, Korea
| | - Eui Sun Jeong
- Department of Internal Medicine, Ewha Womans University College of Medicine, Seoul, Korea
| | - Jae Hyun Kim
- Department of Internal Medicine, Kosin University College of Medicine, Busan, Korea
| | - Seong Ran Jeon
- Institute for Digestive Research, Digestive Disease Center, Soonchunhyang University College of Medicine, Seoul, Korea
| |
Collapse
|
5
|
Brodersen JB, Jensen MD, Leenhardt R, Kjeldsen J, Histace A, Knudsen T, Dray X. Artificial Intelligence-assisted Analysis of Pan-enteric Capsule Endoscopy in Patients with Suspected Crohn's Disease: A Study on Diagnostic Performance. J Crohns Colitis 2024; 18:75-81. [PMID: 37527554 DOI: 10.1093/ecco-jcc/jjad131] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Indexed: 08/03/2023]
Abstract
BACKGROUND AND AIM Pan-enteric capsule endoscopy [PCE] is a highly sensitive but time-consuming tool for detecting pathology. Artificial intelligence [AI] algorithms might offer a possibility to assist in the review and reduce the analysis time of PCE. This study examines the agreement between PCE assessments aided by AI technology and standard evaluations, in patients suspected of Crohn's disease [CD]. METHOD PCEs from a prospective, blinded, multicentre study, including patients suspected of CD, were processed by the deep learning solution AXARO® [Augmented Endoscopy, Paris, France]. Based on the image output, two observers classified the patient's PCE as normal or suggestive of CD, ulcerative colitis, or cancer. The primary outcome was per-patient sensitivities and specificities for detecting CD and inflammatory bowel disease [IBD]. Complete reading of PCE served as the reference standard. RESULTS A total of 131 patients' PCEs were analysed, with a median recording time of 303 min. The AXARO® framework reduced output to a median of 470 images [2.1%] per patient, and the pooled median review time was 3.2 min per patient. For detecting CD, the observers had a sensitivity of 96% and 92% and a specificity of 93% and 90%, respectively. For the detection of IBD, both observers had a sensitivity of 97% and had a specificity of 91% and 90%, respectively. The negative predictive value was 95% for CD and 97% for IBD. CONCLUSIONS Using the AXARO® framework reduced the initial review time substantially while maintaining high diagnostic accuracy-suggesting its use as a rapid tool to rule out IBD in PCEs of patients suspected of Crohn's disease.
Collapse
Affiliation(s)
- Jacob Broder Brodersen
- Department of Internal Medicine, Section of Gastroenterology, Hospital of South West Jutland, Esbjerg, Denmark
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Michael Dam Jensen
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark
- Department of Internal Medicine, Section of Gastroenterology, Lillebaelt Hospital, Vejle, Denmark
| | - Romain Leenhardt
- Équipes Traitement de l'Information et Systèmes, ETIS UMR 8051, CY Paris Cergy University, ENSEA, CNRS, Cergy, France
- Sorbonne University, Center for Digestive Endoscopy, Saint-Antoine Hospital, APHP, Paris, France
| | - Jens Kjeldsen
- Department of Medical Gastroenterology, Odense University Hospital, Odense, Denmark
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
- OPEN Odense Patient Data Explorative Network, Odense University Hospital, Odense, Denmark
| | - Aymeric Histace
- Équipes Traitement de l'Information et Systèmes, ETIS UMR 8051, CY Paris Cergy University, ENSEA, CNRS, Cergy, France
| | - Torben Knudsen
- Department of Internal Medicine, Section of Gastroenterology, Hospital of South West Jutland, Esbjerg, Denmark
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Xavier Dray
- Équipes Traitement de l'Information et Systèmes, ETIS UMR 8051, CY Paris Cergy University, ENSEA, CNRS, Cergy, France
- Sorbonne University, Center for Digestive Endoscopy, Saint-Antoine Hospital, APHP, Paris, France
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
6
|
Singeap AM, Sfarti C, Minea H, Chiriac S, Cuciureanu T, Nastasa R, Stanciu C, Trifan A. Small Bowel Capsule Endoscopy and Enteroscopy: A Shoulder-to-Shoulder Race. J Clin Med 2023; 12:7328. [PMID: 38068379 PMCID: PMC10707315 DOI: 10.3390/jcm12237328] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 11/17/2023] [Accepted: 11/24/2023] [Indexed: 01/11/2025] Open
Abstract
Traditional methods have their limitations when it comes to unraveling the mysteries of the small bowel, an area historically seen as the "black box" of the gastrointestinal tract. This is where capsule endoscopy and enteroscopy have stepped in, offering a remarkable synergy that transcends the sum of their individual capabilities. From their introduction, small bowel capsule endoscopy and device-assisted enteroscopy have consistently evolved and improved, both on their own and interdependently. Each technique's history may be told as a success story, and their interaction has revolutionized the approach to the small bowel. Both have advantages that could be ideally combined into a perfect technique: safe, non-invasive, and capable of examining the entire small bowel, taking biopsies, and applying therapeutical interventions. Until the realization of this perfect tool becomes a reality, the key for an optimal approach lies in the right selection of exploration method. In this article, we embark on a journey through the intertwined development of capsule endoscopy and enteroscopy, exploring the origins, technological advancements, clinical applications, and evolving inquiries that have continually reshaped the landscape of small bowel imaging.
Collapse
Affiliation(s)
- Ana-Maria Singeap
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Catalin Sfarti
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Horia Minea
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Stefan Chiriac
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Tudor Cuciureanu
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Robert Nastasa
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Carol Stanciu
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| | - Anca Trifan
- Department of Gastroenterology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.-M.S.); (C.S.); (S.C.); (T.C.); (R.N.); (C.S.); (A.T.)
- Institute of Gastroenterology and Hepatology, “St. Spiridon” University Hospital, 700111 Iasi, Romania
| |
Collapse
|
7
|
Ribeiro T, Mascarenhas Saraiva MJ, Afonso J, Cardoso P, Mendes F, Martins M, Andrade AP, Cardoso H, Mascarenhas Saraiva M, Ferreira J, Macedo G. Design of a Convolutional Neural Network as a Deep Learning Tool for the Automatic Classification of Small-Bowel Cleansing in Capsule Endoscopy. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59040810. [PMID: 37109768 PMCID: PMC10145655 DOI: 10.3390/medicina59040810] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 04/03/2023] [Accepted: 04/06/2023] [Indexed: 04/29/2023]
Abstract
Background and objectives: Capsule endoscopy (CE) is a non-invasive method to inspect the small bowel that, like other enteroscopy methods, requires adequate small-bowel cleansing to obtain conclusive results. Artificial intelligence (AI) algorithms have been seen to offer important benefits in the field of medical imaging over recent years, particularly through the adaptation of convolutional neural networks (CNNs) to achieve more efficient image analysis. Here, we aimed to develop a deep learning model that uses a CNN to automatically classify the quality of intestinal preparation in CE. Methods: A CNN was designed based on 12,950 CE images obtained at two clinical centers in Porto (Portugal). The quality of the intestinal preparation was classified for each image as: excellent, ≥90% of the image surface with visible mucosa; satisfactory, 50-90% of the mucosa visible; and unsatisfactory, <50% of the mucosa visible. The total set of images was divided in an 80:20 ratio to establish training and validation datasets, respectively. The CNN prediction was compared with the classification established by consensus of a group of three experts in CE, currently considered the gold standard to evaluate cleanliness. Subsequently, how the CNN performed in diagnostic terms was evaluated using an independent validation dataset. Results: Among the images obtained, 3633 were designated as unsatisfactory preparation, 6005 satisfactory preparation, and 3312 with excellent preparation. When differentiating the classes of small-bowel preparation, the algorithm developed here achieved an overall accuracy of 92.1%, with a sensitivity of 88.4%, a specificity of 93.6%, a positive predictive value of 88.5%, and a negative predictive value of 93.4%. The area under the curve for the detection of excellent, satisfactory, and unsatisfactory classes was 0.98, 0.95, and 0.99, respectively. Conclusions: A CNN-based tool was developed to automatically classify small-bowel preparation for CE, and it was seen to accurately classify intestinal preparation for CE. The development of such a system could enhance the reproducibility of the scales used for such purposes.
Collapse
Affiliation(s)
- Tiago Ribeiro
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
| | - Miguel José Mascarenhas Saraiva
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
- Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| | - João Afonso
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
| | - Pedro Cardoso
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
| | - Francisco Mendes
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
| | - Miguel Martins
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
| | - Ana Patrícia Andrade
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
- Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| | - Hélder Cardoso
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
- Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| | | | - João Ferreira
- Department of Mechanical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
- INEGI-Institute of Science and Innovation in Mechanical and Industrial Engineering, 4200-465 Porto, Portugal
| | - Guilherme Macedo
- Department of Gasteroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
- Gastroenterology and Hepatology, WGO Gastroenterology and Hepatology Training Centre, 4050-345 Porto, Portugal
- Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| |
Collapse
|
8
|
Small Bowel Capsule Endoscopy within 6 Hours Following Bowel Preparation with Polyethylene Glycol Shows Improved Small Bowel Visibility. Diagnostics (Basel) 2023; 13:diagnostics13030469. [PMID: 36766574 PMCID: PMC9914394 DOI: 10.3390/diagnostics13030469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 01/19/2023] [Accepted: 01/23/2023] [Indexed: 01/31/2023] Open
Abstract
Although bowel preparation influences small bowel visibility for small bowel capsule endoscopy (SBCE), the optimal timing for bowel preparation has not been established yet. Thus, the aim of the study was to evaluate the optimal timing of polyethylene glycol (PEG) for small bowel preparation before SBCE. This multicenter prospective observational study was conducted on patients who underwent SBCE following bowel preparation with polyethylene glycol (PEG). Patients were categorized into three groups according to the time used for completing PEG ingestion: group A, within 6 h; group B, 6-12 h; and group C, over 12 h. The percentage of unclean segment in small bowel (unclean image duration / small bowel transit time × 100) and small bowel visibility quality (SBVQ) were evaluated according to the time interval between the last ingestion of PEG and swallowing of small bowel capsule endoscope. A total of 90 patients were enrolled and categorized into group A (n = 40), group B (n = 27), and group C (n = 23). The percentage of unclean segment in the entire small bowel increased gradually from group A to C (6.6 ± 7.6% in group A, 11.3 ± 11.8% in group B, and 16.2 ± 10.7% in group C, p = 0.001), especially in the distal small bowel (11.4 ± 13.6% in group A, 20.7 ± 18.7% in group B, and 29.5 ± 16.4% in group C, p < 0.001). The proportion of patients with adequate SBVQ in group A was significantly (p < 0.001) higher (30/40, 75.0%) than that in group B (17/27, 63.0%) or group C (5/23, 21.7%). In multivariate analysis, group A was associated with an increased likelihood of adequate SBVQ compared with group C (odds ratio [OR]: 13.05; 95% confidence interval [CI]: 3.53-48.30, p < 0.001). Completing PEG ingestion within 6 h prior to SBCE could enhance small bowel visibility.
Collapse
|
9
|
Lee HH, Kim JS, Goong HJ, Lee SH, Oh EH, Park J, Kim MC, Nam K, Yang YJ, Kim TJ, Nam SJ, Moon HS, Kim JH, Kim DH, Kim SE, Jeon SR, Myung SJ. [Use of Device-Assisted Enteroscopy in Small Bowel Disease: An Expert Consensus Statement by the Korean Association for the Study of Intestinal Diseases]. THE KOREAN JOURNAL OF GASTROENTEROLOGY = TAEHAN SOHWAGI HAKHOE CHI 2023; 81:1-16. [PMID: 36695062 DOI: 10.4166/kjg.2022.133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/03/2022] [Accepted: 12/06/2022] [Indexed: 01/26/2023]
Abstract
The introduction of device-assisted enteroscopy (DAE) in the beginning of the 21st century has revolutionized the diagnosis and treatment of diseases of the small intestine. In contrast to capsule endoscopy, the other main diagnostic modality of small bowel diseases, DAE has the unique advantages of allowing the observation of the region of interest in detail and enabling tissue acquisition and therapeutic intervention. As DAE becomes an essential procedure in daily clinical practice, there is an increasing need for correct guidelines on when and how it is to be performed and what technical factors should be taken into consideration. In response to these needs, the Korean Association for the Study of Intestinal Diseases has developed an expert consensus statement on the performance of DAE by reviewing current evidence. This expert consensus statement particularly focuses on the indications, choice of insertion route, therapeutic intervention, complications, and relevant technical points.
Collapse
Affiliation(s)
- Han Hee Lee
- Department of Internal Medicine, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Jin Su Kim
- Department of Internal Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Hyeon Jeong Goong
- Department of Internal Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea
| | - Shin Hee Lee
- Department of Internal Medicine, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Eun Hye Oh
- Department of Internal Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Jihye Park
- Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Min Cheol Kim
- Department of Internal Medicine, Yeungnam University Medical Center, Yeungnam University College of Medicine, Daegu, Korea
| | - Kwangwoo Nam
- Department of Internal Medicine, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea
| | - Young Joo Yang
- Department of Internal Medicine, Hallym University Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Korea
| | - Tae Jun Kim
- Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung-Joo Nam
- Department of Internal Medicine, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Korea
| | - Hee Seok Moon
- Department of Internal Medicine, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea
| | - Jae Hyun Kim
- Department of Internal Medicine, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Duk Hwan Kim
- Digestive Disease Center, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| | - Seong-Eun Kim
- Department of Internal Medicine, Ewha Womans University Mokdong Hospital, Ewha Womans University College of Medicine, Seoul, Korea
| | - Seong Ran Jeon
- Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Seung-Jae Myung
- Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
10
|
Lee HH, Kim JS, Goong HJ, Lee SH, Oh EH, Park J, Kim MC, Nam K, Yang YJ, Kim TJ, Nam SJ, Moon HS, Kim JH, Kim DH, Kim SE, Jeon SR, Myung SJ, The Small Intestine Research Group of the Korean Association for the Study of Intestinal Diseases (KASID). Use of device-assisted enteroscopy in small bowel disease: an expert consensus statement by the Korean Association for the Study of Intestinal Diseases. Intest Res 2023; 21:3-19. [PMID: 36751042 PMCID: PMC9911273 DOI: 10.5217/ir.2022.00108] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/07/2022] [Accepted: 11/12/2022] [Indexed: 02/09/2023] Open
Abstract
The introduction of device-assisted enteroscopy (DAE) in the beginning of 21st century has revolutionized the diagnosis and treatment of diseases of the small intestine. In contrast to capsule endoscopy, the other main diagnostic modality of the small bowel diseases, DAE has the unique advantages of observing the region of interest in detail and enabling tissue acquisition and therapeutic intervention. As DAE becomes an essential procedure in daily clinical practice, there is an increasing need for correct guidelines on when and how to perform it and what technical factors should be considered. In response to these needs, the Korean Association for the Study of Intestinal Diseases developed an expert consensus statement on the performance of DAE by reviewing the current evidence. This expert consensus statement particularly focuses on the indications, choice of insertion route, therapeutic intervention, complications, and relevant technical points.
Collapse
Affiliation(s)
- Han Hee Lee
- Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Jin Su Kim
- Department of Internal Medicine, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Hyeon Jeong Goong
- Department of Internal Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea
| | - Shin Hee Lee
- Department of Internal Medicine, Daejeon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Eun Hye Oh
- Department of Internal Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Jihye Park
- Department of Internal Medicine and Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
| | - Min Cheol Kim
- Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea
| | - Kwangwoo Nam
- Department of Gastroenterology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea
| | - Young Joo Yang
- Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Korea
| | - Tae Jun Kim
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung-Joo Nam
- Department of Internal Medicine, Kangwon National University School of Medicine, Chuncheon, Korea
| | - Hee Seok Moon
- Department of Internal Medicine, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea
| | - Jae Hyun Kim
- Department of Internal Medicine, Kosin University College of Medicine, Busan, Korea
| | - Duk Hwan Kim
- Digestive Disease Center, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| | - Seong-Eun Kim
- Department of Internal Medicine, Ewha Womans University College of Medicine, Seoul, Korea
| | - Seong Ran Jeon
- Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Seung-Jae Myung
- Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - The Small Intestine Research Group of the Korean Association for the Study of Intestinal Diseases (KASID)
- Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
- Department of Internal Medicine, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
- Department of Internal Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea
- Department of Internal Medicine, Daejeon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
- Department of Internal Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
- Department of Internal Medicine and Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea
- Department of Gastroenterology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea
- Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Korea
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Internal Medicine, Kangwon National University School of Medicine, Chuncheon, Korea
- Department of Internal Medicine, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea
- Department of Internal Medicine, Kosin University College of Medicine, Busan, Korea
- Digestive Disease Center, CHA Bundang Medical Center, CHA University, Seongnam, Korea
- Department of Internal Medicine, Ewha Womans University College of Medicine, Seoul, Korea
- Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea
- Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
11
|
Quality indicators for capsule endoscopy and deep enteroscopy. Gastrointest Endosc 2022; 96:693-711. [PMID: 36175176 DOI: 10.1016/j.gie.2022.08.039] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 08/31/2022] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Capsule endoscopy (CE) and deep enteroscopy (DE) can be useful for diagnosing and treating suspected small-bowel disease. Guidelines and detailed recommendations exist for the use of CE/DE, but comprehensive quality indicators are lacking. The goal of this task force was to develop quality indicators for appropriate use of CE/DE by using a modified RAND/UCLA Appropriateness Method. METHODS An expert panel of 7 gastroenterologists with diverse practice experience was assembled to identify quality indicators. A literature review was conducted to develop a list of proposed quality indicators applicable to preprocedure, intraprocedure, and postprocedure periods. The panelists reviewed the literature; identified and modified proposed quality indicators; rated them on the basis of scientific evidence, validity, and necessity; and determined proposed performance targets. Agreement and consensus with the proposed indicators were verified using the RAND/UCLA Appropriateness Method. RESULTS The voting procedure to prioritize metrics emphasized selecting measures to improve quality and overall patient care. Panelists rated indicators on the perceived appropriateness and necessity for clinical practice. After voting and discussion, 2 quality indicators ranked as inappropriate or uncertain were excluded. Each quality indicator was categorized by measure type, performance target, and summary of evidence. The task force identified 13 quality indicators for CE and DE. CONCLUSIONS Comprehensive quality indicators have not existed for CE or DE. The task force identified quality indicators that can be incorporated into clinical practice. The panel also addressed existing knowledge gaps and posed research questions to better inform future research and quality guidelines for these procedures.
Collapse
|
12
|
Abstract
INTRODUCTION Capsule endoscopy (CE) and deep enteroscopy (DE) can be useful for diagnosing and treating suspected small-bowel disease. Guidelines and detailed recommendations exist for the use of CE/DE, but comprehensive quality indicators are lacking. The goal of this task force was to develop quality indicators for appropriate use of CE/DE by using a modified RAND/UCLA Appropriateness Method. METHODS An expert panel of 7 gastroenterologists with diverse practice experience was assembled to identify quality indicators. A literature review was conducted to develop a list of proposed quality indicators applicable to preprocedure, intraprocedure, and postprocedure periods. The panelists reviewed the literature; identified and modified proposed quality indicators; rated them on the basis of scientific evidence, validity, and necessity; and determined proposed performance targets. Agreement and consensus with the proposed indicators were verified using the RAND/UCLA Appropriateness Method. RESULTS The voting procedure to prioritize metrics emphasized selecting measures to improve quality and overall patient care. Panelists rated indicators on the perceived appropriateness and necessity for clinical practice. After voting and discussion, 2 quality indicators ranked as inappropriate or uncertain were excluded. Each quality indicator was categorized by measure type, performance target, and summary of evidence. The task force identified 13 quality indicators for CE and DE. DISCUSSION Comprehensive quality indicators have not existed for CE or DE. The task force identified quality indicators that can be incorporated into clinical practice. The panel also addressed existing knowledge gaps and posed research questions to better inform future research and quality guidelines for these procedures.
Collapse
|
13
|
Limpias Kamiya KJ, Hosoe N, Hayashi Y, Kawaguchi T, Takabayashi K, Ogata H, Kanai T. Video capsule endoscopy in inflammatory bowel disease. DEN OPEN 2022; 2:e26. [PMID: 35310695 PMCID: PMC8828198 DOI: 10.1002/deo2.26] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 04/30/2021] [Indexed: 12/22/2022]
Abstract
Since its introduction into clinical practice in 2000, capsule endoscopy (CE) has become an important procedure for many pathologies of small bowel (SB) diseases, including inflammatory bowel disease (IBD). Currently, the most commonly used capsule procedures are small bowel capsule endoscopy (SBCE), colon CE (CCE), and the recently developed pan-enteric CE that evaluates the SB and colon in patients with Crohn's disease (CD). SBCE has a higher diagnostic performance compared to other radiological and conventional endoscopic modalities in patients with suspected CD. Additionally, CE plays an important role in monitoring the activity of CD in SB. It can also be used in evaluating response to anti-inflammatory treatment and detecting recurrence in postsurgical patients with CD who underwent bowel resection. Due to its increasing use, different scoring systems have been developed specifically for IBD. The main target with CCE is ulcerative colitis (UC). The second-generation colon capsule has shown high performance for the assessment of inflammation in patients with UC. CCE allows noninvasive evaluation of mucosal inflammation with a reduced volume of preparation for patients with UC.
Collapse
Affiliation(s)
- Kenji J.L. Limpias Kamiya
- Division of Gastroenterology and HepatologyDepartment of Internal MedicineKeio University School of MedicineTokyoJapan
| | - Naoki Hosoe
- Center for Diagnostic and Therapeutic EndoscopyKeio University School of MedicineTokyoJapan
| | - Yukie Hayashi
- Division of Gastroenterology and HepatologyDepartment of Internal MedicineKeio University School of MedicineTokyoJapan
| | - Takaaki Kawaguchi
- Division of Gastroenterology and HepatologyDepartment of Internal MedicineKeio University School of MedicineTokyoJapan
| | - Kaoru Takabayashi
- Center for Diagnostic and Therapeutic EndoscopyKeio University School of MedicineTokyoJapan
| | - Haruhiko Ogata
- Center for Diagnostic and Therapeutic EndoscopyKeio University School of MedicineTokyoJapan
| | - Takanori Kanai
- Division of Gastroenterology and HepatologyDepartment of Internal MedicineKeio University School of MedicineTokyoJapan
| |
Collapse
|
14
|
Ahmed M. Video Capsule Endoscopy in Gastroenterology. Gastroenterology Res 2022; 15:47-55. [PMID: 35572472 PMCID: PMC9076159 DOI: 10.14740/gr1487] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 03/14/2022] [Indexed: 11/27/2022] Open
Abstract
Video capsule endoscopy (VCE) is a wireless technology used by gastroenterologists for various indications in their clinical practice. There has been significant improvement in this technology since its start about two decades ago. Specific video capsules have been made to evaluate the small bowel, colon, and esophagus. Now pan-enteric video capsule is available to assess both the small bowel and colon. VCE is a non-invasive procedure that has been tremendously evaluated for various gastrointestinal disorders, particularly small intestinal bleeding. There are specific contraindications and complications of VCE. This procedure has the technical part and video reading part. Newer software programs will come to reduce the reading time. Artificial intelligence is also coming for quick and accurate diagnosis of any positive findings during VCE. VCE is an important diagnostic test in the field of gastroenterology. Although it is an addition to optical endoscopic procedures to visualize the gastrointestinal mucosa, it has advantages and disadvantages.
Collapse
Affiliation(s)
- Monjur Ahmed
- Thomas Jefferson University Hospital, Philadelphia, PA 19107, USA.
| |
Collapse
|
15
|
Cho YK, Park H, Moon JR, Jeon SR, Kim HG, Lee TH, Park J, Kim JO, Lee JS, Goong HJ, Ko BM, Park S. Clinical Outcomes between P1 and P0 Lesions for Obscure Gastrointestinal Bleeding with Negative Computed Tomography and Capsule Endoscopy. Diagnostics (Basel) 2021; 11:diagnostics11040657. [PMID: 33917389 PMCID: PMC8067371 DOI: 10.3390/diagnostics11040657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 04/01/2021] [Accepted: 04/01/2021] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND A simple classification for the relevance of lesions (P0, P1, and P2; no bleeding potential, less likely to bleed, and more likely to bleed, respectively) based on capsule endoscopy (CE) findings has been used. This study aimed at investigating rebleeding rates and predictive factors of P0 and P1 lesions after obtaining negative findings in both, CE and computed tomography (CT), for patients with obscure gastrointestinal bleeding (OGIB). METHODS Among 193 patients resulted in negative CE findings defined as P0 or P1 lesions, 84 patients with negative results on CT images were enrolled in this study. The rebleeding rates and predictive factors were assessed in the P0 and P1 groups. RESULTS Overall rebleeding rate in patients with negative CT and CE was 17.9%; 18.4% in the P0 group; 17.4% in the P1 group within a median follow-up duration of 18.5 months. In the P0 and P1 groups, the cumulative rebleeding rates were 9.2%, 25.4%, and 25.4%, and 6.9%, 11.8%, and 18.6% at 12, 24, and 60 months, respectively (p = 0.97). There were no independent rebleeding associated factors in the P0 group, whereas Charlson comorbidity index (CCI) (hazard ratio (HR) = 2.019, 95% confidence interval (CI): 1.158-3.519, p = 0.013), and initial low hemoglobin (Hb) level (<8 g/dL) (HR = 15.085, 95% CI: 1.182-192.514, p = 0.037) were independent predictive factors responsible for rebleeding in the P1 group. CONCLUSIONS Despite having negative findings on CT and CE, patients with OGIB have a significant potential rebleeding risk. Although there was no significant difference in rebleeding rates between the P0 and P1 groups on CE, the P1 group, with CCI or low initial Hb level, should be cautiously observed after the first bleeding episode.
Collapse
Affiliation(s)
- Young Kyu Cho
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Heesu Park
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Jung Rock Moon
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Seong Ran Jeon
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
- Correspondence: ; Tel.: +82-2-709-9202; Fax: +82-2-709-9581
| | - Hyun Gun Kim
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Tae Hee Lee
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Junseok Park
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Jin-Oh Kim
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Joon Seong Lee
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Hyeon Jeong Goong
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Bong Min Ko
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea; (Y.K.C.); (H.P.); (J.R.M.); (H.G.K.); (T.H.L.); (J.P.); (J.-O.K.); (J.S.L.); (H.J.G.); (B.M.K.)
| | - Suyeon Park
- Department of biostatistics, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-Gu, Seoul 04401, Korea;
| |
Collapse
|
16
|
Double-headed small-bowel capsule endoscopy: Real-world experience from a multi-centre British study. Dig Liver Dis 2021; 53:461-466. [PMID: 33574013 DOI: 10.1016/j.dld.2021.01.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 01/10/2021] [Accepted: 01/20/2021] [Indexed: 12/11/2022]
Abstract
INTRODUCTION Capsule endoscopy (CE) is well established the investigation of small-bowel (SB) pathology. We compared the use of double-headed (DH) capsules, to conventional single-headed (SH), in a real-world patient cohort in the first multicentre British study. METHODS Over 9 months, patients referred for routine SBCE at 4 tertiary referral centres in the UK underwent DH CE instead of conventional SH using MiroCamⓇ MC2000 as per local protocols. One head (L/R) was chosen at random and reported by an expert reviewer. The DH recordings, anonymised and randomised, reported by another expert or re-read after a 4-week interval. For each CE, numbers and types of findings and overall conclusion/diagnosis were compared between SH and DH examinations. RESULTS 211 CEs were performed. 7 failed to reach the SB; 204 analysed. Indications were: SB bleeding (n = 94); ?SB inflammation or reassessment of known inflammatory bowel disease (IBD) (n = 84); ?SB neoplasia including suspicious radiological imaging (n = 15); and, others e.g. ?celiac disease (n = 11). For SB bleeding: 27/94 (28.7%) examinations reported differences between SH and DH readings. In 17 (18.1%) the findings were clinically significant. SH CE missed angiectasias (5 pts), SB inflammation (7 pts), oesophagitis (2 pts) and SB masses (2 pts). In 1 patient, the extent of angiectasias seen was greater on the DH reading. For IBD: findings differed in 30/84 (35.7%) of CEs; 11 (13.1%) were clinically significant. In 5, signs of active inflammation were missed by the SH reading. In 6, assessment of extent/severity differed. For?SB neoplasia findings differed in 2/15 (13.3%) of examinations. Both were clinically significant. For others: 1/11 (9.1%) examinations differed; however, not deemed clinically significant. Overall, use of DH CE impacted the diagnosis in 30/204 (14.7%). CONCLUSIONS The use of DH CE provides more information with the potential to change clinical diagnosis and therefore management. Therefore, the routine adoption of DH CE in SB assessment should be considered.
Collapse
|
17
|
Hilmi I, Kobayashi T. Capsule endoscopy in inflammatory bowel disease: when and how. Intest Res 2020; 18:265-274. [PMID: 32623876 PMCID: PMC7385570 DOI: 10.5217/ir.2019.09165] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 05/26/2020] [Indexed: 12/19/2022] Open
Abstract
Capsule endoscopy (CE) is emerging as an important investigation in inflammatory bowel disease (IBD); common types include the standard small bowel CE and colon CE. More recently, the pan-enteric CE was developed to assess the large and small bowel in patients with Crohn’s disease (CD). Emerging indications include noninvasive assessment for mucosal healing (both in the small bowel and the colon) and detection of postoperative recurrence in patients with CD. Given the increasing adoption, several CE scoring systems have been specifically developed for IBD. The greatest concern with performing CE, particularly in CD, is capsule retention, but this can be overcome by performing cross-sectional imaging such as magnetic resonance enterography and using patency capsules before performing the procedure. The development of software for automated detection of mucosal abnormalities typically seen in IBD may further increase its adoption.
Collapse
Affiliation(s)
- Ida Hilmi
- Department of Medicine, University of Malaya Medical Centre, Kuala Lumpur, Malaysia
| | - Taku Kobayashi
- Center for Advanced IBD Research and Treatment, Kitasato University Kitasato Institute Hospital, Tokyo, Japan
| |
Collapse
|
18
|
Jeon SR. Use of small bowel capsule endoscopy in clinical practice: how has it performed? Korean J Intern Med 2020; 35:854-856. [PMID: 32668517 PMCID: PMC7373979 DOI: 10.3904/kjim.2020.291] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 06/12/2020] [Indexed: 02/07/2023] Open
Affiliation(s)
- Seong Ran Jeon
- Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, Seoul, Korea
- Correspondence to Seong Ran Jeon, M.D. Digestive Disease Center, Institute for Digestive Research, Soonchunhyang University College of Medicine, 59 Daesagwan-ro, Yongsan-gu, Seoul 04401, Korea Tel: +82-2-709-9202 Fax: +82-2-709-9696 E-mail:
| |
Collapse
|
19
|
Gao Y, Xin L, Wang YX, Dong YH, Liao Z, Li ZS, Du YQ. Double-balloon enteroscopy for retrieving retained small-bowel video capsule endoscopes: a systematic review. Scand J Gastroenterol 2020; 55:105-113. [PMID: 31865808 DOI: 10.1080/00365521.2019.1703036] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Background and aim: Capsule retention is the most common adverse event associated with video capsule endoscopy. The use of double-balloon enteroscopy-assisted capsule endoscope retrieval has been increasingly reported in recent years. However, evidence is limited regarding its success rate, associated factors, and subsequent clinical outcomes.Methods: A systematic review of relevant studies published before January 2019 was performed. Successful retrieval rate and associated factors, rate of endoscopic balloon dilation, and outcomes after double-balloon enteroscopy were summarized and pooled.Results: Within 154 associated original articles, 12 including 150 cases of capsule retrieval by double-balloon enteroscopy were included. The estimated pooled successful retrieval rate was 86.5% (95% confidence interval, 75.6-95.1%). Anterograde approach and capsules retained in the jejunum or trapped by malignant strictures were associated with a higher successful retrieval rate than the retrograde approach (62/83 [74.7%] vs. 10/38 [26.3%], p < .001) and capsules retained in the ileum (41/41 [100.0%] vs. 43/58 [74.1%], p < .001) or trapped by benign strictures (21/21 [100.0%] vs. 65/83 [78.3%], p = .043). Endoscopic balloon dilation was performed in 38.8% (95% confidence interval, 22.3-56.3%) of patients with benign strictures. Two perforations (1.3%) were reported as severe adverse events after double-balloon enteroscopy. A significantly lower surgery rate was found among cases with successful video capsule removal compared with unsuccessful cases (7.2% vs. 38.5%, p = .002).Conclusions: Double-balloon enteroscopy is feasible and safe for removing retained video capsule endoscopes, and its use could decrease the need for surgery in patients with benign strictures and facilitate subsequent surgery in patients with malignant strictures.
Collapse
Affiliation(s)
- Ye Gao
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| | - Lei Xin
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| | - Yu-Xin Wang
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| | - Yuan-Hang Dong
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| | - Zhuan Liao
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| | - Zhao-Shen Li
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| | - Yi-Qi Du
- Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.,National Clinical Research Center for Digestive Diseases, Shanghai, China
| |
Collapse
|
20
|
Lee HS, Lim YJ, Kim KO, Jang HJ, Chun J, Jeon SR, Jung Y, Kim JH, Park JJ, Boo SJ, Kang SH, Nam SJ, Lee YJ. Outcomes and Management Strategies for Capsule Retention: A Korean Capsule Endoscopy Nationwide Database Registry Study. Dig Dis Sci 2019; 64:3240-3246. [PMID: 31076988 DOI: 10.1007/s10620-019-05659-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2019] [Accepted: 05/03/2019] [Indexed: 12/22/2022]
Abstract
BACKGROUND The most concerning complication of capsule endoscopy (CE) is capsule retention (CR) in the gastrointestinal (GI) tract; however, the clinical outcomes and management of patients with CR are still uncertain. AIMS This study aimed to investigate the clinical outcomes and management of CR. METHODS The outcomes of CR in multiple centers between October 2002 and June 2018 were retrospectively reviewed. Data on CE indication, findings, and management details were analyzed. RESULTS A total of 2705 consecutive small-bowel CE procedures were performed. CR was detected in 20 cases (0.7%). The most common site of CR was the small bowel (19 cases), followed by the esophagus (one case). In patients who underwent CE, CR was detected in nine (0.6%) of 1397 patients with obscure GI bleeding. Further, CR occurred in 11 (6.5%) of 169 patients with Crohn's disease based on the final diagnoses after CE. Capsule retrieval was safely performed surgically in nine cases and endoscopically in six cases. The retained capsules dislodged after steroid treatment in two cases, whereas three cases of CR resolved without any intervention. In multivariate analysis, the development of abdominal symptoms after CR was a significant predictive factor for requiring endoscopic or surgical interventions for capsule extraction. CONCLUSIONS This large multicenter study shows that CR is a rare complication with favorable clinical outcomes. Three-fourths of the patients with CR were managed with endoscopic or surgical intervention, which was required particularly in patients with abdominal symptoms after CR.
Collapse
Affiliation(s)
- Hyun Seok Lee
- Department of Internal Medicine, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Daegu, Republic of Korea
| | - Yun Jeong Lim
- Department of Internal Medicine, Dongguk University College of Medicine, Dongguk University Ilsan Hospital, 27 Dongguk-ro, Ilsandong-gu, Goyang, Republic of Korea.
| | - Kyeong Ok Kim
- Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Republic of Korea
| | - Hyun Joo Jang
- Department of Internal Medicine, Hallym University College of Medicine, Hwasung, Republic of Korea
| | - Jaeyoung Chun
- Department of Internal Medicine, Liver Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Seong Ran Jeon
- Department of Internal Medicine, Soonchunhyang University College of Medicine, Seoul, Republic of Korea
| | - Yunho Jung
- Department of Internal Medicine, Soonchunhyang University College of Medicine, Cheonan, Republic of Korea
| | - Ji Hyun Kim
- Department of Internal Medicine, Inje University College of Medicine, Busan, Republic of Korea
| | - Jae Jun Park
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Sun-Jin Boo
- Department of Internal Medicine, Jeju National University School of Medicine, Jeju, Republic of Korea
| | - Sun Hyung Kang
- Department of Internal Medicine, Chungnam National University School of Medicine, Daejeon, Republic of Korea
| | - Seung-Joo Nam
- Department of Internal Medicine, Kangwon National University School of Medicine, Chuncheon, Republic of Korea
| | - Yoo Jin Lee
- Department of Internal Medicine, Keimyung University School of Medicine, Daegu, Republic of Korea
| | | |
Collapse
|
21
|
Teng LH, Yang T, Lu JW, Liu WL. Analysis of small bowel angioectasia in asymptomatic individuals depending on patients' age and gender. Scand J Gastroenterol 2019; 54:1364-1369. [PMID: 31738618 DOI: 10.1080/00365521.2019.1688385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Objectives: Small bowel angioectasia (SBA) plays an important role in the etiologies of obscure gastrointestinal haemorrhage. But the exact prevalence of the disease is unknown, especially in asymptomatic populations. Therefore, we aimed to evaluate the prevalence of asymptomatic angioectasia in the small bowel (SB) with magnetically controlled capsule gastroscopy (MCCG).Methods: We retrospectively collected a multicentre clinical data of 508 asymptomatic patients who underwent MCCG from June 2018 to May 2019. Bowel cleanliness was rated as four grades according to the criteria, and the excellent or good preparation was classified as the adequate group. The detection rates of small bowel lesions were analysed according to the ages, genders and bowel preparations.Results: A total of 508 individuals have completed the examination. There were 316 men and 192 women with an average age of 44.5 years old. The prevalence of SBA was 11.8% (95% CI: 9.0-14.6%). 70.0% of them were over 40 years old and 73.3% were male although there was no obvious disparity found in age and gender for the SBA. Most findings were located in the proximal small bowel (jejunum). The incidence of small bowel lesions was not related to bowel preparations (p > .05).Conclusions: SBA is not uncommon in asymptomatic individuals. Age and gender may be risk factors for bleeding of angioectasia in the small bowel, but they seem to have little to do with the occurrence of it. MCCG showed no difference in ages, genders or bowel preparations of small bowel lesions among our study population.
Collapse
Affiliation(s)
- Li-Hong Teng
- Department of Gastroenterology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Tao Yang
- Department of Gastroenterology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Jia-Wei Lu
- Department of Gastroenterology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Wei-Li Liu
- Department of Gastroenterology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
22
|
Rondonotti E, Spada C, Pennazio M, de Franchis R, Cadoni S, Girelli C, Hassan C, Marmo R, Riccioni ME, Scarpulla G, Soncini M, Vecchi M, Cannizzaro R. Adherence to European Society of Gastrointestinal Endoscopy recommendations of endoscopists performing small bowel capsule endoscopy in Italy. Dig Liver Dis 2019; 51:818-823. [PMID: 30639228 DOI: 10.1016/j.dld.2018.11.031] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Revised: 11/20/2018] [Accepted: 11/25/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND The European Society of Gastrointestinal Endoscopy (ESGE) has recently issued a technical review focused on small bowel capsule endoscopy (SBCE). AIM To compare SBCE current practice in Italy to ESGE technical recommendations. MATERIAL AND METHODS A dedicated per-centre semi-quantitative questionnaire was prepared by a group of SBCE experts. One-hundred-fifty Centres were invited to participate in the data collection concerning SBCEs performed between June 2016 and June 2017. Data were compared with ESGE recommendations. RESULTS 120 Centres participated in the data collection. Current practices agreed with ESGE recommendations in 56.3% (9/16) of the issues evaluated. Differences between ESGE recommendations and current practice concerned the management of patients with pacemakers or cardiac implantable defibrillators (which was in agreement with ESGE recommendations in 31.7% and 15.8% of Centres, respectively), the SBCE setting (only 51% of SBCEs were performed as outpatients procedures), the assessment of capsule excretion (timing and modality were in agreement with ESGE recommendation in 20.0% of Centres), and in the involvement of trained nurses or fellows in training as pre-readers (7/120; 5.8%). CONCLUSIONS Although SBCE is widely used and largely available in Italy, there are still some technical, practical and organizational issues that can be modified to bridge the gap between current practice and ESGE guideline recommendations.
Collapse
Affiliation(s)
| | - Cristiano Spada
- Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy; Digestive Endoscopy Unit, Poliambulanza Foundation, Brescia, Italy
| | - Marco Pennazio
- Division of Gastroenterology U, San Giovanni AS University-Teaching Hospital, Torino, Italy
| | | | - Sergio Cadoni
- Digestive Endoscopy Unit, CTO Hospital, Iglesias, Italy
| | - Carlo Girelli
- Gastroenterology and Digestive Endoscopy Unit, Hospital of Busto Arsizio, Busto Arsizio, Italy
| | - Cesare Hassan
- Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy
| | - Riccardo Marmo
- Division of Gastroenterology, Curto Hospital, Polla, Italy
| | - Maria Elena Riccioni
- Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy; Digestive Endoscopy Unit, Catholic University of Rome, Rome, Italy
| | | | - Marco Soncini
- Digestive Physiopathology Unit ASST Santi Paolo e Carlo, Milan, Italy
| | - Maurizio Vecchi
- Dipartimento di Scienze Biomediche per la Salute, Università di Milano, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Renato Cannizzaro
- Division of Oncological Gastroenterology, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Aviano, Italy
| |
Collapse
|
23
|
CapsoCam SV-1 Versus PillCam SB 3 in the Detection of Obscure Gastrointestinal Bleeding: Results of a Prospective Randomized Comparative Multicenter Study. J Clin Gastroenterol 2019; 53:e101-e106. [PMID: 29369240 DOI: 10.1097/mcg.0000000000000994] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND AND STUDY AIM Newer capsule with a panoramic viewing mode is available and might increase the detection rate of bleeding lesions in patients with obscure gastrointestinal bleeding (OGIB). Furthermore, an improved patient acceptance rate is expected. MATERIALS AND METHODS In a randomized prospective comparative multicenter study, patients with OGIB were included and examined either with CapsoCam SV-1 or with PillCam SB 3. Detection of bleeding lesions, transit, and evaluation time and adverse events were evaluated. Physicians were interviewed about their experience with both capsules and the evaluation software. A detailed subject questionnaire analyzed acceptance of each capsule. Follow-up was 3 months. RESULTS In total, 181 patients with OGIB were recruited into the study. After exclusion of 28 patients 153 patients were randomized and CapsoCam SV-1 (n=78) or PillCam SB 3 (n=75) was administered. CapsoCam SV-1 detected more cases of bleeding (31/79, diagnostic yield 39.7%) compared with PillCam SB 3 (26/75, diagnostic yield 34.6%, NS). Transit time of both capsules was not different. Evaluation time with PillCam SB 3 was superior to CapsoCam SV-1 (27 vs. 40 min, P=0.01). In total, 95% of the physicians were satisfied with each capsule system and evaluation software. The acceptance rate of the patients to retrieve the CapsoCam SV-1 was high. Adverse events/serious adverse events were 17.9%/1.3% with CapsoCam SV-1 and 16%/0% with PillCam SB 3. Rebleeding rate was 28.75% within 3 months. CONCLUSIONS CapsoCam SV-1 detected more lesions; however, relevant bleeding sources were visualized by both capsules. Physician's satisfaction was high with both capsule systems and evaluation software. Patient's acceptance with CapsoCam SV-1 was unexpectedly high. Serious adverse events were 0% with PillCam SB 3 and 1.3% with CapsoCam SV-1.
Collapse
|
24
|
Park J, Hwang Y, Yoon JH, Park MG, Kim J, Lim YJ, Chun HJ. Recent Development of Computer Vision Technology to Improve Capsule Endoscopy. Clin Endosc 2019; 52:328-333. [PMID: 30786704 PMCID: PMC6680009 DOI: 10.5946/ce.2018.172] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 11/25/2018] [Indexed: 12/24/2022] Open
Abstract
Capsule endoscopy (CE) is a preferred diagnostic method for analyzing small bowel diseases. However, capsule endoscopes capture a sparse number of images because of their mechanical limitations. Post-procedural management using computational methods can enhance image quality. Additional information, including depth, can be obtained by using recently developed computer vision techniques. It is possible to measure the size of lesions and track the trajectory of capsule endoscopes using the computer vision technology, without requiring additional equipment. Moreover, the computational analysis of CE images can help detect lesions more accurately within a shorter time. Newly introduced deep leaning-based methods have shown more remarkable results over traditional computerized approaches. A large-scale standard dataset should be prepared to develop an optimal algorithms for improving the diagnostic yield of CE. The close collaboration between information technology and medical professionals is needed.
Collapse
Affiliation(s)
- Junseok Park
- Digestive Disease Center, Institute for Digestive Research, Department of Internal Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Youngbae Hwang
- Intelligent Image Processing Research Center, Korea Electronics Technology Institute (KETI), Seongnam, Korea
| | - Ju-Hong Yoon
- Intelligent Image Processing Research Center, Korea Electronics Technology Institute (KETI), Seongnam, Korea
| | - Min-Gyu Park
- Intelligent Image Processing Research Center, Korea Electronics Technology Institute (KETI), Seongnam, Korea
| | - Jungho Kim
- Intelligent Image Processing Research Center, Korea Electronics Technology Institute (KETI), Seongnam, Korea
| | - Yun Jeong Lim
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea
| | - Hoon Jai Chun
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Institute of Gastrointestinal Medical Instrument Research, Korea University College of Medicine, Seoul, Korea
| |
Collapse
|
25
|
|
26
|
Kim SH, Yang DH, Kim JS. Current Status of Interpretation of Small Bowel Capsule Endoscopy. Clin Endosc 2018; 51:329-333. [PMID: 30078306 PMCID: PMC6078920 DOI: 10.5946/ce.2018.095] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2018] [Accepted: 07/18/2018] [Indexed: 02/06/2023] Open
Abstract
Capsule endoscopy (CE) has revolutionized direct small bowel imaging and is widely used in clinical practice. Remote visualization of bowel images enables painless, well-tolerated endoscopic examinations. Small bowel CE has a high diagnostic yield and the ability to examine the entire small bowel. The diagnostic yield of CE relies on lesion detection and interpretation. In this review, issues related to lesion detection and interpretation of CE have been addressed, and the current status of automated reading software development has been reviewed. Clinical significance of an external real-time image viewer has also been described.
Collapse
Affiliation(s)
- Su Hwan Kim
- Department of Internal Medicine, Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea
| | - Dong-Hoon Yang
- Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jin Su Kim
- Division of Gastroenterology, Department of Internal Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea College of Medicine, Seoul, Korea
| |
Collapse
|
27
|
Mitselos IV, Christodoulou DK. What defines quality in small bowel capsule endoscopy. ANNALS OF TRANSLATIONAL MEDICINE 2018; 6:260. [PMID: 30094246 DOI: 10.21037/atm.2018.05.28] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Small bowel capsule endoscopy is considered a first-line diagnostic tool for the investigation of small bowel diseases. Gastroenterological and endoscopic societies have proposed and established measures known as quality indicators, quality measures or performance measures for the majority of endoscopic procedures, in order to ensure competence, healthcare quality and define areas requiring improvement. However, there is a paucity of publications describing small bowel capsule endoscopy quality indicators. Hereby, we attempt to identify and describe a number of pre-procedure, intra-procedure and post-procedure quality indicators, regarding process measures in small bowel capsule endoscopy, after a comprehensive review of the literature.
Collapse
Affiliation(s)
- Ioannis V Mitselos
- Department of Gastroenterology, School of Health Sciences, University Hospital of Ioannina, Faculty of Medicine, University of Ioannina, Ioannina, Greece
| | - Dimitrios K Christodoulou
- Department of Gastroenterology, School of Health Sciences, University Hospital of Ioannina, Faculty of Medicine, University of Ioannina, Ioannina, Greece
| |
Collapse
|
28
|
Mohammed A, Farup I, Pedersen M, Hovde Ø, Yildirim Yayilgan S. Stochastic Capsule Endoscopy Image Enhancement. J Imaging 2018; 4:75. [DOI: 10.3390/jimaging4060075] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2023] Open
Abstract
Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.
Collapse
Affiliation(s)
- Ahmed Mohammed
- Department of Computer Science, Norwegian University of Science and Technology, 2815 Gjøvik, Norway
| | - Ivar Farup
- Department of Computer Science, Norwegian University of Science and Technology, 2815 Gjøvik, Norway
| | - Marius Pedersen
- Department of Computer Science, Norwegian University of Science and Technology, 2815 Gjøvik, Norway
| | - Øistein Hovde
- Department of Gastroenterology, Innlandet Hospital Trust, Institute of Clinical Medicine, University of Oslo, 0315 Oslo, Norway
| | - Sule Yildirim Yayilgan
- Department of Information Security and Communication Technology Norwegian University of Science and Technology, 2815 Gjøvik, Norway
| |
Collapse
|
29
|
Stanich PP, Peck J, Murphy C, Porter KM, Meyer MM. Physical activity during video capsule endoscopy correlates with shorter bowel transit time. Endosc Int Open 2017; 5:E856-E860. [PMID: 28924590 PMCID: PMC5595578 DOI: 10.1055/s-0043-115385] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Accepted: 06/21/2017] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND AND STUDY AIM Video capsule endoscopy (VCE) is limited by reliance on bowel motility for propulsion, and lack of physical activity has been proposed as a cause of incomplete studies. Our aim was to prospectively investigate the association between physical activity and VCE bowel transit. PATIENTS AND METHODS Ambulatory outpatients receiving VCE were eligible for the study. A pedometer was attached at the time of VCE ingestion and step count was recorded at the end of the procedure. VCE completion was assessed by logistic regression models, which included step count (500 steps as one unit). Total transit time was analyzed by Cox proportional hazards models. The hazard ratios (HR) with 95 % confidence interval (CI) indicated the "hazard" of completion, such that HRs > 1 indicated a reduced transit time. RESULTS A total of 100 patients were included. VCE was completed in 93 patients (93 %). The median step count was 2782 steps. Step count was not significantly associated with VCE completion (odds ratio 1.45, 95 %CI 0.84, 2.49). Pedometer step count was significantly associated with shorter total, gastric, and small-bowel transit times (HR 1.09, 95 %CI 1.03, 1.16; HR 1.05, 95 %CI 1.00, 1.11; HR 1.07, 95 %CI 1.01, 1.14, respectively). Higher body mass index (BMI) was significantly associated with VCE completion (HR 1.87, 95 %CI 1.18, 2.97) and shorter bowel transit times (HR 1.05, 95 %CI 1.02, 1.08). CONCLUSIONS Increased physical activity during outpatient VCE was associated with shorter bowel transit times but not with study completion. In addition, BMI was a previously unreported clinical characteristic associated with VCE completion and should be included as a variable of interest in future studies.
Collapse
Affiliation(s)
- Peter P. Stanich
- Section of Capsule Endoscopy, Division of Gastroenterology, Hepatology and Nutrition, The Ohio State University Wexner Medical Center, Columbus, Ohio, United States
| | - Joshua Peck
- Section of Capsule Endoscopy, Division of Gastroenterology, Hepatology and Nutrition, The Ohio State University Wexner Medical Center, Columbus, Ohio, United States
| | - Christopher Murphy
- Section of Capsule Endoscopy, Division of Gastroenterology, Hepatology and Nutrition, The Ohio State University Wexner Medical Center, Columbus, Ohio, United States
| | - Kyle M. Porter
- Center for Biostatistics, The Ohio State University Wexner Medical Center, Columbus, Ohio, United States
| | - Marty M. Meyer
- Section of Capsule Endoscopy, Division of Gastroenterology, Hepatology and Nutrition, The Ohio State University Wexner Medical Center, Columbus, Ohio, United States,Corresponding author Marty M. Meyer, MD Ohio State University Wexner Medical Center395 West 12th Avenue, Suite 200Columbus, OH 43210United States+1-614-293-8518
| |
Collapse
|