1
|
Li W, Kotsou T, Hartog H, Scheenstra R, de Meijer VE, Stenekes MW, Verhagen MV, Bokkers RPH, van der Doef HPJ. Hepatic artery stenosis after pediatric liver transplantation: The potential role of conservative management. Dig Liver Dis 2025; 57:502-511. [PMID: 39379231 DOI: 10.1016/j.dld.2024.09.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 09/17/2024] [Accepted: 09/19/2024] [Indexed: 10/10/2024]
Abstract
AIM This study aimed to investigate the outcomes and effectiveness of various treatment strategies in patients with hepatic artery stenosis (HAS) after pediatric liver transplantation (pLT). METHODS This is a single center observational cohort study between January 1st, 2004 and August 1st, 2023, including pLT recipients aged <18 years. The primary outcome was graft and patient survival. The secondary outcomes included incidence of biliary complications, technical success of surgery or endovascular therapy (EVT), and changes in liver function. The cut-off for early and late HAS was 14 days after pLT. RESULTS Among a total of 327 pLT patients, 4 % (n = 13) developed HAS (n = 3 early; n = 10 late). Treatments included surgical revascularization for one early HAS, conservative management with anticoagulation for one early and four late HAS, and EVT for one early and six late HAS. Over a median follow-up of 28.2 months after the diagnosis of HAS, graft survival was 100 % and 83 % in early and late HAS groups, and patient survival reached 100 % in both groups. One graft loss occurred in the conservative group. Conversely, graft survival in the EVT group was 100 %. CONCLUSION The long-term outcomes of HAS after pLT are excellent. Both EVT and conservative management exhibited high graft survival rates for late HAS, with EVT achieving high technical success.
Collapse
Affiliation(s)
- Weihao Li
- Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Thomai Kotsou
- Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands; Faculty of Medical Sciences, University of Groningen, Groningen, the Netherlands
| | - Hermien Hartog
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Rene Scheenstra
- Division of Pediatric Gastroenterology and Hepatology, Department of Pediatrics, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Vincent E de Meijer
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Martin W Stenekes
- Department of Plastic and Reconstructive Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Martijn V Verhagen
- Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Reinoud P H Bokkers
- Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Hubert P J van der Doef
- Division of Pediatric Gastroenterology and Hepatology, Department of Pediatrics, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
| |
Collapse
|
2
|
Minciuna I, den Hoed C, van der Meer AJ, Sonneveld MJ, Sprengers D, de Knegt RJ, de Jonge J, Maan R, Polak WG, Darwish Murad S. The Yield of Routine Post-Operative Doppler Ultrasound to Detect Early Post-Liver Transplantation Vascular Complications. Transpl Int 2023; 36:11611. [PMID: 38093807 PMCID: PMC10716223 DOI: 10.3389/ti.2023.11611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 11/17/2023] [Indexed: 12/18/2023]
Abstract
Early detection of liver transplantation (LT) vascular complications enables timely management. Our aim was to assess if routine Doppler ultrasound (rDUS) improves the detection of hepatic artery thrombosis (HAT), portal vein thrombosis (PVT) and hepatic venous outflow obstruction (HVOO). We retrospectively analysed timing and outcomes, number needed to diagnose one complication (NND) and positive predictive value (PPV) of rDUS on post-operative day (POD) 0,1 and 7 in 708 adult patients who underwent primary LT between 2010-2022. We showed that HAT developed in 7.1%, PVT in 8.2% and HVOO in 3.1% of patients. Most early complications were diagnosed on POD 0 (26.9%), 1 (17.3%) and 5 (17.3%). rDUS correctly detected 21 out of 26 vascular events during the protocol days. PPV of rDUS was 53.8%, detection rate 1.1% and NND was 90.5. Median time to diagnosis was 4 days for HAT and 47 days for PVT and 21 days for HVOO. After intervention, liver grafts were preserved in 57.1%. In conclusion, rDUS protocol helps to detect first week's vascular events, but with low PPV and a high number of ultrasounds needed.
Collapse
Affiliation(s)
- Iulia Minciuna
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
- Department V- Gastroenterology, University of Medicine and Pharmacy “Iuliu Hatieganu”, Cluj-Napoca, Romania
- Regional Institute of Gastroenterology and Hepatology “O. Fodor”, Cluj-Napoca, Romania
| | - Caroline den Hoed
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Adriaan J. van der Meer
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Milan J. Sonneveld
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Dave Sprengers
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Robert J. de Knegt
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Jeroen de Jonge
- Department of Surgery, Division of HPB and Transplant Surgery, Erasmus MC Transplant Institute University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Raoel Maan
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Wojciech G. Polak
- Department of Surgery, Division of HPB and Transplant Surgery, Erasmus MC Transplant Institute University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Sarwa Darwish Murad
- Department of Gastroenterology and Hepatology, Erasmus MC Transplant Institute, Erasmus MC University Medical Center Rotterdam, Rotterdam, Netherlands
| |
Collapse
|
3
|
Malik MS, Akoh JA, Houlberg K. The Use of the Implantable Doppler Probe as a Blood Flow Monitoring Device in Clinical Settings: A Narrative Review of the Evidence. EXP CLIN TRANSPLANT 2023; 21:83-92. [PMID: 36919717 DOI: 10.6002/ect.2022.0349] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
OBJECTIVES In the past decade, the implantable Doppler probe has been studied widely as a blood flow-monitoring device in reconstructive and transplant surgical specialities. Its utility as an effective postoperative monitoring technique is still debatable, with no clear guidelines in clinical practice. Here, we mapped the current evidence on the usefulness of the implantable Doppler probe as a blood flow-monitoring device. The objective was to present an up-to-date assessment of the benefits and limitations of using implantable Doppler probes in clinical and experimental clinical settings. MATERIALS AND METHODS We conducted a literature search using the Cochrane Library and Healthcare Databases Advanced Search and using implantable Doppler probe, transplant, graft, and flap as key words. The search yielded 184 studies, with 73 studies included after exclusions. We evaluated, synthesized, and summarized the evidence from the studies in tabular form. RESULTS There is clinical equipoise regarding the effectiveness of implantable Doppler probe as a flow sensing technique. The main reason is the lack of information and gaps in the evidence regarding the benefits and limitations of using implantable Doppler probes in clinical practice. CONCLUSIONS The implantable Doppler probe has the potentialto be used as an adjunctpostoperativeblood flow-monitoring device. However, keeping in view of technical limitations, its signals should be interpreted alongside traditional clinical assessment techniques to determine the patency of microvascular anastomosis. Although evidence in this review will inform clinical practice in transplant and reconstructive surgical specialties, a prospective randomized controlled study with a larger patient cohort is required to evaluate the effectiveness of this probe in clinical settings.
Collapse
|
4
|
Dumortier J, Besch C, Moga L, Coilly A, Conti F, Corpechot C, Del Bello A, Faitot F, Francoz C, Hilleret MN, Houssel-Debry P, Jezequel C, Lavayssière L, Neau-Cransac M, Erard-Poinsot D, de Lédinghen V, Bourlière M, Bureau C, Ganne-Carrié N. Non-invasive diagnosis and follow-up in liver transplantation. Clin Res Hepatol Gastroenterol 2022; 46:101774. [PMID: 34332131 DOI: 10.1016/j.clinre.2021.101774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 07/23/2021] [Indexed: 02/04/2023]
Abstract
The field of liver transplantation directly or indirectly embodies all liver diseases, in addition to specific ones related to organ rejection (cellular and humoral). The recommended non-invasive methods for determining the indication for liver transplantation are the Model for End-stage Liver Disease score, and the alpha-foetoprotein score in case of hepatocellular carcinoma. Radiological methods are the cornerstones for the diagnosis of vascular and biliary complications after liver transplantation. The possible diseases of the liver graft after transplantation are multiple and often intertwined. Non-invasive diagnostic methods have been poorly evaluated in this context, apart from the recurrence of hepatitis C. Liver biopsy remains the gold standard for evaluating graft lesions in the majority of cases, especially graft rejection.
Collapse
Affiliation(s)
- Jérôme Dumortier
- Service d'hépato-gastroentérologie, Unité de transplantation hépatique, Hôpital Edouard Herriot - HCL, CHU Lyon, Lyon.
| | - Camille Besch
- Service de chirurgie hépato-bilio-pancréatique et transplantation hépatique, Hôpital Hautepierre, CHRU Strasbourg, Strasbourg
| | - Lucile Moga
- Service d'Hépatologie et Transplantation Hépatique, Hôpital Beaujon, APHP, Clichy
| | - Audrey Coilly
- Centre Hépato-Biliaire, Hôpital Paul Brousse, APHP, Villejuif
| | - Filomena Conti
- Service d'Hépatologie et Transplantation Hépatique, Hôpital de la Pitié Salpétrière, APHP, Paris
| | | | - Arnaud Del Bello
- Département de néphrologie et transplantation d'organes, Hôpital Rangueil, CHU Toulouse, Toulouse
| | - François Faitot
- Service de chirurgie hépato-bilio-pancréatique et transplantation hépatique, Hôpital Hautepierre, CHRU Strasbourg, Strasbourg
| | - Claire Francoz
- Service d'Hépatologie et Transplantation Hépatique, Hôpital Beaujon, APHP, Clichy
| | | | | | | | - Laurence Lavayssière
- Département de néphrologie et transplantation d'organes, Hôpital Rangueil, CHU Toulouse, Toulouse
| | | | - Domitille Erard-Poinsot
- Service d'hépato-gastroentérologie, Unité de transplantation hépatique, Hôpital Edouard Herriot - HCL, CHU Lyon, Lyon
| | - Victor de Lédinghen
- Unité Transplantation Hépatique, Hôpital Haut-Lévêque, CHU Bordeaux, Bordeaux
| | - Marc Bourlière
- Service d'hépato-gastroentérologie, Hôpital Saint Joseph & INSERM UMR 1252 IRD SESSTIM Aix Marseille Université, Marseille
| | | | - Nathalie Ganne-Carrié
- Service d'hépatologie, Hôpital Avicenne, APHP, Université Sorbonne Paris Nord, Bobigny & INSERM UMR 1138, Centre de Recherche des Cordeliers, Université de Paris
| |
Collapse
|
5
|
Vasant Kulkarni S, Rao PP, Naidu C, Pathak N, Singh A. Evaluation of implantable Doppler probe continuous monitoring of hepatic artery anastomosis after liver transplantation. Med J Armed Forces India 2021. [DOI: https:/doi.org/10.1016/j.mjafi.2020.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
6
|
Vasant Kulkarni S, Rao PP, Naidu C, Pathak N, Singh A. Evaluation of implantable Doppler probe continuous monitoring of hepatic artery anastomosis after liver transplantation. Med J Armed Forces India 2021; 77:349-354. [PMID: 34305290 PMCID: PMC8282509 DOI: 10.1016/j.mjafi.2020.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Accepted: 03/24/2020] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Thrombosis of hepatic artery anastomosis (HAT) after liver transplantation is a catastrophic and dreaded complication. Early identification of HAT can salvage the situation. To monitor the anastomosis, conventional daily transcutaneous Doppler is performed. However, it has disadvantages of being noncontinuous, operator-dependent and technically difficult. Implantable Doppler probes wrapped around the anastomosed vessel giving continuous signal may be an important tool; however, very few studies are performed to study its efficacy after intra-abdominal vascular anastomosis, and its role is not clearly established. METHODS Patients who underwent deceased donor liver transplant surgery were part of the study. On hepatic arterial anastomosis, implantable Doppler probe was fixed for monitoring. Conventional daily transcutaneous Doppler was also performed and the results were compared. RESULTS A total of 40 hepatic arterial anastomoses were studied. The incidence of HAT was 10.53%. For the implantable Doppler probe monitoring, sensitivity and negative predictive value was 100%, whereas specificity was 94.44% and positive predictive value was 66.66% with an overall accuracy of 95%. A mean of 10 h of lead time was gained by implantable Doppler probe monitoring. CONCLUSION Our study showed that there was high sensitivity and negative predictive value of implantable Doppler probe monitoring system, which makes it ideal for post-operative vascular anastomoses surveillance monitoring; however, abnormal positive finding on implantable Doppler probe monitoring needs to be confirmed by conventional transcutaneous Doppler. The implantable Doppler probe monitoring, because of its round the clock and continuous nature gives us a good lead time in identifying vascular complication, which translates into graft salvage and reduction in morbidity and mortality.
Collapse
Affiliation(s)
- Shrirang Vasant Kulkarni
- Classified Specialist (Surgery) & GI Surgeon, Command Hospital (Southern Command), Pune 411040, India
| | - Pankaj P. Rao
- Professor & Head, Department of Surgery, Armed Forces Medical College, Pune 411040, India
| | - C.S. Naidu
- CMO, Eastern Naval Command, Visakhapatnam, India
| | - N. Pathak
- Classified Specialist (Surgery) & GI Surgeon, Military Hospital, Jaipur, India
| | - A.K. Singh
- Senior Advisor (Surgery & GI Surgery), INHS Asvini, Mumbai, India
| |
Collapse
|
7
|
Calinescu AM, Wildhaber BE. Early Vascular Complications. PEDIATRIC LIVER TRANSPLANTATION 2021:181-191. [DOI: 10.1016/b978-0-323-63671-1.00020-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
|
8
|
Lee DD, Paz-Fumagalli R, Croome KP, Paz D, Wright L, Nguyen JH, Taner CB. Hepatic artery stenosis after liver transplant: Donation after cardiac death donor vs donation after brain death donor grafts. Clin Transplant 2018; 32:e13413. [DOI: 10.1111/ctr.13413] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Revised: 08/26/2018] [Accepted: 09/15/2018] [Indexed: 12/22/2022]
Affiliation(s)
- David D. Lee
- Department of Transplantation; Mayo Clinic Florida and Mayo Clinic Collaborative in Transplant Research and Outcomes; Jacksonville Florida
| | | | - Kristopher P. Croome
- Department of Transplantation; Mayo Clinic Florida and Mayo Clinic Collaborative in Transplant Research and Outcomes; Jacksonville Florida
| | - Diego Paz
- Clinical Research Internship Study Program (CRISP) Mayo Clinic Florida; Jacksonville Florida
| | - Lauren Wright
- Department of Transplantation; Mayo Clinic Florida and Mayo Clinic Collaborative in Transplant Research and Outcomes; Jacksonville Florida
| | - Justin H. Nguyen
- Department of Transplantation; Mayo Clinic Florida and Mayo Clinic Collaborative in Transplant Research and Outcomes; Jacksonville Florida
| | - C. Burcin Taner
- Department of Transplantation; Mayo Clinic Florida and Mayo Clinic Collaborative in Transplant Research and Outcomes; Jacksonville Florida
| |
Collapse
|
9
|
Schlemm L. Disability Adjusted Life Years due to Ischaemic Stroke Preventable by Real-Time Stroke Detection-A Cost-Utility Analysis of Hypothetical Stroke Detection Devices. Front Neurol 2018; 9:814. [PMID: 30327638 PMCID: PMC6174318 DOI: 10.3389/fneur.2018.00814] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 09/10/2018] [Indexed: 11/13/2022] Open
Abstract
Background: Ischaemic stroke remains a significant contributor to permanent disability world-wide. Therapeutic interventions for acute ischaemic stroke (AIS) are available, but need to be administered early after symptom onset in order to be effective. Currently, one of the main factors responsible for poor clinical outcome is an unnecessary long time between symptom onset and arrival at a hospital (pre-hospital delay). In the future, technological devices with the capability of real-time detection of AIS may become available. The health economic implications of such devices have not been explored. Methods: We developed a novel probabilistic model to estimate the maximally allowable annual costs of different hypothetical real-time AIS detection devices in different populations given currently accepted willingness-to-pay thresholds. Distributions of model parameters were extracted from the literature. Effectiveness of the intervention was quantified as reduction in disability-adjusted life-years associated with faster access to thrombolysis and mechanical thrombectomy. Incremental costs were calculated from a societal perspective including acute treatment costs and long-term costs for nursing care, home help, and loss of production. The impact of individual model parameters was explored in one-way and multi-way sensitivity analyses. Results: The model yields significantly shorter prehospital delays and a higher proportion of acute ischaemic patients that fulfill the time-based eligibility criteria for thrombolysis or mechanical thrombectomy in the scenario with a real-time stroke detection device as compared to the control scenario. Depending on the sociodemographic and geographic characteristics of the study population and operating characteristics of the device, the maximally allowable annual cost for the device to operate in a cost-effective manner assuming a willingness-to-pay threshold of GBP 30.000 ranges from GBP 22.00 to GBP 9,952.00. Considering the results of multiway sensitivity analyses, the upper bound increases to GBP 29,449.10 in the subgroup of young patients with a very high annual risk of ischaemic stroke (50 years/20% annual risk). Conclusion: Data from probabilistic modeling suggest that real-time AIS detection devices can be expected to be cost-effective only for a small group of highly selected individuals.
Collapse
Affiliation(s)
- Ludwig Schlemm
- Department of Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Center for Stroke Research Berlin, Charité-Universitätsmedizin, Berlin, Germany.,Berlin Institute of Health, Berlin, Germany.,Department of Health Policy, London School of Economics and Political Science, London, United Kingdom
| |
Collapse
|
10
|
Amdisen C, Jespersen B, Møldrup U, Keller AK. The unsuitability of implantable Doppler probes for the early detection of renal vascular complications - a porcine model for prevention of renal transplant loss. PLoS One 2017; 12:e0178301. [PMID: 28542429 PMCID: PMC5444816 DOI: 10.1371/journal.pone.0178301] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Accepted: 05/10/2017] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion. METHODS In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were randomised to stepwise venous occlusion, complete venous occlusion, complete arterial occlusion or controls. RESULTS All parameters were stable through baseline measurements. Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular occlusions on the vessel it was placed. CONCLUSIONS We developed a new model for stepwise renal venous blood flow occlusion. Furthermore, the first comparison of the implantable Doppler probe and microdialysis for detection of renal vascular occlusions was made. The implantable Doppler probe could only detect flow changes after a complete occlusion, whereas microdialysis detected changes earlier, and could detect both arterial and venous occlusion. Based on these results, the implantable Doppler probe for early detection of vascular occlusions cannot be recommended.
Collapse
Affiliation(s)
- Chris Amdisen
- Institute of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark
- Department of Renal Medicine, Aarhus University Hospital, Aarhus, Denmark
- * E-mail:
| | - Bente Jespersen
- Department of Renal Medicine, Aarhus University Hospital, Aarhus, Denmark
| | - Ulla Møldrup
- Department of Urology, Aarhus University Hospital, Aarhus, Denmark
| | - Anna K. Keller
- Department of Urology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
11
|
Gu LH, Li FH, Xia Q, Fang H, Zhang SJ, Han LZ. Diagnosis and outcomes of collateral arterial formation after irreversible early hepatic artery thrombosis in pediatric liver recipients. Hepatobiliary Pancreat Dis Int 2017; 16:39-44. [PMID: 28119257 DOI: 10.1016/s1499-3872(16)60165-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Early hepatic artery thrombosis (eHAT) has been recognized as an important cause of graft loss and mortality. However, the incidence, etiology and outcome are not clear, especially for children. The present study was to investigate the formation of collateral artery flow after irreversible eHAT and its impact on patient's prognosis. METHODS We analyzed eHAT after liver transplantation in children from October 2006 to April 2015 in our center, illustrated the formation of collateral hepatic artery flow after irreversible eHAT and explored the diagnosis, complications, treatment and prognosis. The basic and follow-up ultrasonographic images were also compared. RESULTS Of the 330 pediatric liver recipients, 22 (6.67%) developed eHAT within 1 month. Revascularization attempts including surgical thrombectomy, interventional radiology and conservational treatment (thrombolysis) were successful in 5 patients. Among the 17 patients who had irreversible eHAT, follow-up ultrasonography revealed that collateral artery flow was developed as early as 2 weeks after eHAT. Liver abscess and bile duct complication occurred secondary to eHAT in variable time. CONCLUSIONS Collateral arterial formation is a compensatory adaptation to eHAT to supply blood to liver grafts. However, the severe bile duct damage secondary to eHAT is irreversible and retransplantation is unavoidable.
Collapse
Affiliation(s)
- Li-Hong Gu
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China.
| | | | | | | | | | | |
Collapse
|
12
|
Girometti R, Como G, Bazzocchi M, Zuiani C. Post-operative imaging in liver transplantation: State-of-the-art and future perspectives. World J Gastroenterol 2014; 20:6180-6200. [PMID: 24876739 PMCID: PMC4033456 DOI: 10.3748/wjg.v20.i20.6180] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Accepted: 01/20/2014] [Indexed: 02/06/2023] Open
Abstract
Orthotopic liver transplantation (OLT) represents a major treatment for end-stage chronic liver disease, as well as selected cases of hepatocellular carcinoma and acute liver failure. The ever-increasing development of imaging modalities significantly contributed, over the last decades, to the management of recipients both in the pre-operative and post-operative period, thus impacting on graft and patients survival. When properly used, imaging modalities such as ultrasound, multidetector computed tomography, magnetic resonance imaging (MRI) and procedures of direct cholangiography are capable to provide rapid and reliable recognition and treatment of vascular and biliary complications occurring after OLT. Less defined is the role for imaging in assessing primary graft dysfunction (including rejection) or chronic allograft disease after OLT, e.g., hepatitis C virus (HCV) recurrence. This paper: (1) describes specific characteristic of the above imaging modalities and the rationale for their use in clinical practice; (2) illustrates main imaging findings related to post-OLT complications in adult patients; and (3) reviews future perspectives emerging in the surveillance of recipients with HCV recurrence, with special emphasis on MRI.
Collapse
|
13
|
Saito Y, Yoshizumi T, Harada N, Kayashima H, Yamasaki K, Sadanaga N, Matsuura H, Okadome K. Hepatic artery aneurysm in a patient with hepatitis C liver cirrhosis: report of a case. Clin J Gastroenterol 2013; 6:169-72. [PMID: 26181457 DOI: 10.1007/s12328-013-0372-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Accepted: 02/18/2013] [Indexed: 11/28/2022]
Abstract
Visceral artery aneurysms are rare, with an incidence rate of only 0.01-0.2 % in routine autopsies, and hepatic artery aneurysms account for approximately 20 % of these aneurysms. Despite recent advances in therapeutic techniques and diagnostic tools, the management of visceral artery aneurysms remains clinically challenging. We report a case of hepatic artery aneurysm with liver cirrhosis due to hepatitis C in an 81-year-old woman. A computed tomography scan demonstrated a hepatic artery aneurysm 4.4 cm in diameter. She underwent successful aneurysmectomy with vascular anastomosis. A computed tomography scan on postoperative day 7 demonstrated patent hepatic artery. The patient was followed-up for 1 year after surgery and died owing to progressive liver failure. However, she did not show any hepatic artery problem such as hepatic arterial thrombosis or occlusion. We discuss the risk factors of atherosclerosis in patients with liver cirrhosis, and present an overview of the treatment of hepatic artery aneurysms.
Collapse
Affiliation(s)
- Yu Saito
- Department of Surgery, The University of Tokushima, Tokushima, 770-8501, Japan.,Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| | - Tomoharu Yoshizumi
- Department of Surgery and Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, 812-8582, Japan. .,Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan.
| | - Noboru Harada
- Department of Surgery and Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, 812-8582, Japan.,Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| | - Hiroto Kayashima
- Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| | - Koji Yamasaki
- Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| | - Noriaki Sadanaga
- Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| | - Hiroshi Matsuura
- Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| | - Kenichiro Okadome
- Department of Surgery, Saiseikai Fukuoka General Hospital, Fukuoka, 810-0001, Japan
| |
Collapse
|