1
|
Miller A, Anderson JC. Strategies, Technologies, and Tips for Successful Cecal Intubation. J Clin Gastroenterol 2025; 59:16-23. [PMID: 39495781 DOI: 10.1097/mcg.0000000000002096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2024] [Accepted: 10/02/2024] [Indexed: 11/06/2024]
Abstract
Successful cecal intubation is crucial in ensuring a complete evaluation of the colonic mucosa. Although completion of colonoscopies should be successful in close to 100% of all examinations in the hands of experienced gastroenterologists, there are some patients with colons which can be difficult to navigate. Factors such as older age, presence of diverticular disease, as well as high or low body mass index can present challenges for endoscopists. Challenges can be divided into those that are left sided and are associated with severe angulations of the colon versus those that are right sided and present as redundant colons. Both require different strategies to achieve completion. This review will cover methods, technologies as well the evolution of colonoscope insertion tubes which can help in navigating colons, especially those that are challenging. There will also be a discussion about basic principles and techniques that should be employed in all colonoscopies.
Collapse
Affiliation(s)
| | - Joseph C Anderson
- University of Connecticut, School of Medicine
- Geisel School of Medicine at Dartmouth, Hanover, NH
- White River Junction VAMC, White River Junction, VT
- NH Colonoscopy Registry, Lebanon, NH, USA
| |
Collapse
|
2
|
Chen X, Zhu X, Wei B, Ji L, Yang C, Zhan Q. Comparison of the characteristics of the CF-H290I and PCF-Q260JI colonoscopes in non-sedated patients with a history of abdominal or pelvic surgery: a randomized controlled study. J Gastroenterol Hepatol 2024; 39:457-463. [PMID: 37984841 DOI: 10.1111/jgh.16398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 08/31/2023] [Accepted: 10/18/2023] [Indexed: 11/22/2023]
Abstract
BACKGROUND AND AIM The purpose of this randomized controlled study was to compare the characteristics of the CF-H290I (high-definition) colonoscope with those of the PCF-Q260JI (high-resolution) colonoscope in non-sedated patients with a history of abdominal or pelvic surgery in an effort to help endoscopists to select more effectively and objectively between the various colonoscopes. METHODS A total of 397 patients who underwent colonoscopy at the Affiliated Wuxi People's Hospital of Nanjing Medical University, between August 2022 and October 2022 were randomized to a CF-H290I group (n = 198) or a PCF-Q260JI group (n = 199) using a computer-generated allocation method. We compared the adenoma detection rate (ADR), patient satisfaction with the examination, discomfort associated with colonoscopy including abdominal distension and pain, cecal intubation time, and patient willingness to undergo colonoscopy in the future between the CF-H290I and PCF-Q260JI groups. RESULTS There was no statistically significant difference in the overall ADR between the CF-H290I and PCF-Q260JI groups (81 [40.9%] vs 63 [31.7%], Z = 3.674, P = 0.055). However, the ADRs in the transverse colon and left colon were significantly higher in the CF-H290I group (22 [11.1%] vs 6 [3.0%], Z = 9.588, P = 0.002 and 57 [28.8%] vs 37 [18.6%], Z = 5.212, P = 0.017, respectively). More sessile serrated lesions were detected in the CF-H290I group (52 [26.3] vs 30 [15.1%], Z = 7.579, P = 0.006). Patient satisfaction with colonoscopy was better in the PCF-Q260JI group (8.91 ± 1.09 vs 8.51 ± 1.44, t = -3.158, P < 0.01) with less likelihood of discomfort (23 [11.6%] vs 41 [20.7%], Z = 6.144, P = 0.013), The number of patients willing to undergo colonoscopy in the future was significantly greater in the PCF-Q260JI group (168 [84.4%] vs 149 [75.3%], Z = 5.186, P = 0.023). The cecal intubation time was significantly shorter in the CF-H290I group (256.09 ± 155.70 s vs 315.64 ± 171.64 s, P = 0.004). There were no complications such as perforation or bleeding in either group. CONCLUSION The CF-H290I and PCF-Q260JI colonoscopes each have advantages when used in patients with a history of abdominal or pelvic surgery. The CF-H290I has higher ADRs in the transverse and left colon whereas the PCF-Q260JI is less painful and better accepted by patients. This study was approved by the Clinical Research Ethics Committee of Wuxi People's Hospital and was registered in the Chinese Clinical Trial Registry (ChiCTR2200063092).
Collapse
Affiliation(s)
- Xujin Chen
- Department of Gastroenterology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu Branch of the National Clinical Research Center for Digestive Diseases, Wuxi, China
| | - Xianlan Zhu
- Department of Gastroenterology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu Branch of the National Clinical Research Center for Digestive Diseases, Wuxi, China
| | - Bingni Wei
- Department of Gastroenterology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu Branch of the National Clinical Research Center for Digestive Diseases, Wuxi, China
| | - Lin Ji
- Department of Gastroenterology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu Branch of the National Clinical Research Center for Digestive Diseases, Wuxi, China
| | - Cheng Yang
- Department of Digestive Endoscopy Center, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu Branch of the National Clinical Research Center for Digestive Diseases, Wuxi, China
| | - Qiang Zhan
- Department of Gastroenterology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu Branch of the National Clinical Research Center for Digestive Diseases, Wuxi, China
| |
Collapse
|
3
|
Li JB, Qiu ZY, Deng YX, Li Y, Lin ZC, Wu YP, Weng F, Tian H, Ou QJ, Gong CH, Pan ZZ, Wan DS, Peng JH, Fang YJ. Factors associated with positive predictive value of preliminary screening in a two-step screening strategy for colorectal neoplasms in China. Discov Oncol 2022; 13:4. [PMID: 35201502 PMCID: PMC8777551 DOI: 10.1007/s12672-022-00463-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Accepted: 12/07/2021] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND The positive predictive value (PPV) of high risk factor questionnaire (HRFQ) plus fecal immunochemical test (FIT) as preliminary screening strategy for colorectal-related neoplasia is relatively low. We aim to explore independent factors associated with PPVs of HRFQ combined FIT for selecting high risk individuals for colonoscopy. METHODS A total of 6971 residents were enrolled in a community-based screening program. Participants who had positive results of HRFQ and/or FIT and subsequently received colonoscopy were involved. The associations of socio-demographic factors, lifestyle behaviors, and high risk factors of colorectal cancer with PPVs of HRFQ, FIT, and their combination were evaluated by multivariable logistic regression models. RESULTS Among 572 involved cases, 249 (43.5%) colorectal neoplasms were detected by colonoscopy, including 71 advanced adenoma (12.4%) and 9 colorectal cancer (CRC) (1.6%). The PPVs of preliminary screening were 43.5% for total colorectal neoplasms, 14.0% for advanced neoplasm, and 1.6% for CRC. Adding positive HRFQ to FIT could improve the PPV from 3.5 to 8.0% for detecting CRC. Preliminarily screened positive individuals who were males [adjusted odds ratio (AOR): 1.95, 95% CI 1.31, 2.90; p < 0.001], elders (> 60 years) (AOR: 1.70, 95% CI 1.17, 2.46; p = 0.005), or ex-/current smokers (AOR: 3.04, 95% CI 1.31, 7.09; p = 0.10) had higher odds of PPVs of detecting colorectal neoplasms. CONCLUSIONS Combining HRFQ and FIT could largely improve PPVs for screening advanced neoplasm and CRC. Gender and age-specific FIT cut-off values as well as initiating ages for CRC screening might be recommended to improve the accuracy and effectiveness of current screening algorithm.
Collapse
Affiliation(s)
- Ji-Bin Li
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - Zhi-Yu Qiu
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - Yu-Xiang Deng
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - Yin Li
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - Zhuo-Chen Lin
- Department of Medical Records, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, 510060, People's Republic of China
| | - Yan-Ping Wu
- Yuexiu District Center for Disease Control and Prevention, Guangzhou, 510055, People's Republic of China
| | - Fan Weng
- Yuexiu District Center for Disease Control and Prevention, Guangzhou, 510055, People's Republic of China
| | - Huan Tian
- Dadong Street Community Health Service Center, Guangzhou, 510000, People's Republic of China
| | - Qing-Jian Ou
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - Cheng-Hua Gong
- Yuexiu District Center for Disease Control and Prevention, Guangzhou, 510055, People's Republic of China
| | - Zhi-Zhong Pan
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - De-Sen Wan
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China
| | - Jian-Hong Peng
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China.
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China.
| | - Yu-Jing Fang
- Sun Yat-sen University Cancer Center, Guangzhou, 510060, People's Republic of China.
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China.
| |
Collapse
|
4
|
Efficacy of a small-caliber colonoscope for pain in female patients during unsedated colonoscopy: a randomized controlled study. Endosc Int Open 2021; 9:E1055-E1061. [PMID: 34222630 PMCID: PMC8211489 DOI: 10.1055/a-1464-0780] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 03/02/2021] [Indexed: 12/24/2022] Open
Abstract
Background and study aims Female sex has been identified as a factor increasing patients' pain during colonoscopy. The aim of this randomized controlled study was to investigate the efficacy of a small-caliber colonoscope, PCF-PQ260 L, for limiting pain in women during unsedated colonoscopy. Patients and methods Women who underwent unsedated colonoscopy were randomly allocated to either the small-caliber or standard colonoscope group. The primary outcome was overall pain and secondary outcomes were maximum pain and procedural measures. In addition, the effects of colonoscope type were analysed using analysis of covariance and logistic regression with adjustment for stratification factors, age and prior abdomino-pelvic surgery. Results A total of 220 women were randomly assigned to the small-caliber (n = 110) or standard (n = 110) colonoscope groups. Overall and maximum pain scores were significantly lower in the small-caliber colonoscope group than the standard colonoscope group (overall pain, 20.0 vs. 32.4, P < 0.0001; maximum pain, 28.9 vs. 47.2, P < 0.0001). The small-caliber colonoscope group achieved a superior cecal intubation rate (99 % vs. 93 %, P = 0.035). The rate of patient acceptance of unsedated colonoscopy in the future was higher in the small-caliber colonoscope group than in the standard colonoscope group (98 % vs. 87 %, P = 0.003). In addition, the small-caliber colonoscope was superior with respect to reducing pain and improving the rate of patient acceptance of unsedated colonoscopy with adjustment. Conclusions This study demonstrates the efficacy of the small-caliber colonoscope for reducing pain in women and improving their rate of acceptance of unsedated colonoscopy.
Collapse
|
5
|
Gerges C, Neumann H, Ishaq S, Sivanathan V, Galle PR, Neuhaus H, Neumann H. Evaluation of a novel colonoscope offering flexibility adjuster - a retrospective observational study. Therap Adv Gastroenterol 2021; 14:17562848211013494. [PMID: 34104209 PMCID: PMC8170286 DOI: 10.1177/17562848211013494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 04/07/2021] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Although colonoscopy is the gold standard for colorectal cancer screening, colonic looping may make complete colonoscopy challenging. Commonly available stiffening device colonoscopy has been described as helpful but not effective enough to prevent looping. In this context the effect on cecal intubation time and rate was described differently in various studies and in some studies had no impact on cecal intubation time at all. The aim of this study was to evaluate whether a novel colonoscope with gradual stiffness (Fujifilm EC760R-V/I- flexibility adjuster, Tokyo, Japan) using four significantly different grades of stiffness can be an alternative to established devices in terms of loop prevention, cecal intubation rate and time, adverse events, and patient/examiner satisfaction. METHODS Consecutive patients without previous colorectal surgery were analyzed retrospectively. Colonoscopy was performed with the new colonoscope and performance characteristics, including time to cecum, withdrawal time, total examination time, and patient and endoscopist satisfaction were recorded. RESULTS Among 180 consecutive procedures, 98.3% of examinations were complete to the cecum. The endoscopic flexibility adjuster was used in 150 of 180 cases (83.3%). Overall, the device was scored by the examiner as helpful to prevent looping in 146 of the 150 cases (97.7%). Mean cecal intubation time was 6.5 min, with 35% of examination performed in under 5 min with a mean withdrawal time of 7 min. Mean total examination time was 18 min. Patient satisfaction was rated as high in all examinations performed. CONCLUSION The new flexibility adjuster colonoscope was shown to be helpful in loop prevention, allowed for fast and successful cecal intubation, and led to a high rate of patients satisfaction.
Collapse
Affiliation(s)
- Christian Gerges
- Department of Gastroenterology, Evangelisches
Krankenhaus Düsseldorf, Düsseldorf, Germany
| | | | - Sauid Ishaq
- Department of Gastroenterology, Dudley Group
NHS, Foundation Trust and Birmingham City University, Birmingham, UK
| | - Visvakanth Sivanathan
- Department of Interdisciplinary Endoscopy, I.
Medizinische Klinik und Poliklinik, University Hospital, Mainz,
Germany
| | - Peter R. Galle
- Department of Interdisciplinary Endoscopy, I.
Medizinische Klinik und Poliklinik, University Hospital, Mainz,
Germany
| | - Horst Neuhaus
- Department of Gastroenterology, Evangelisches
Krankenhaus Düsseldorf, Düsseldorf, Germany
| | | |
Collapse
|
6
|
Zhou D, He X. Numerical evaluation of the efficacy of small-caliber colonoscopes in reducing patient pain during a colonoscopy. Comput Methods Biomech Biomed Engin 2018; 22:38-46. [PMID: 30398066 DOI: 10.1080/10255842.2018.1524885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Patient pain caused by a colonoscope is one of the main complications in completing a colonoscopy. Currently, randomized controlled trial (RCT) is one of the most used methods to evaluate the efficacy of small-caliber (SC) colonoscopes in reducing patient pain during a colonoscopy, compared with a standard colonoscope (SDC). However, many disturbing factors, including endoscopists' skills, characteristics of patients and new technical features of the colonoscope (passive bending and high force transmission shaft), limit the reliability and generalizability of each finding in current RCTs. This paper focuses on modeling the insertion of colonoscopes within colon models using an explicit finite element method (FEM). Such a numerical model could overcome the limitations in RCTs. At the same time, it is expected to evaluate the efficacy of the small-caliber colonoscopes in reducing patient pain during a colonoscopy, while considering the effects of patient characteristics, including age, region and gender. The simulation results in this work showed that: compared with the SDC, a SC colonoscope may be more helpful in reducing discomfort for older patients, patients with smaller colon diameters and females.
Collapse
Affiliation(s)
- Debao Zhou
- a Department of Mechanical and Industrial Engineering , University of Minnesota Duluth , MN , USA.,b School of Electronics and Information Engineering , Tianjin Polytechnic University , Tianjin , China
| | - Xuehuan He
- a Department of Mechanical and Industrial Engineering , University of Minnesota Duluth , MN , USA
| |
Collapse
|
7
|
Bugajski M, Wieszczy P, Hoff G, Rupinski M, Regula J, Kaminski MF. Modifiable factors associated with patient-reported pain during and after screening colonoscopy. Gut 2018; 67:1958-1964. [PMID: 28970289 DOI: 10.1136/gutjnl-2017-313905] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 07/31/2017] [Accepted: 09/07/2017] [Indexed: 12/13/2022]
Abstract
OBJECTIVE Pain associated with colonoscopy is a major burden for patients. We investigated modifiable factors associated with patient-reported pain during and after colonoscopy. DESIGN This cross-sectional analysis included database records from 23 centres participating in a population-based colonoscopy screening programme in Poland. Colonoscopies were performed under three sedation modalities: none, benzodiazepine-opioid sedation or propofol sedation. We used Gastronet (a validated tool) to assess patients' pain during and after colonoscopy; pain was scored on a four-point scale (no, little, moderate or severe pain), with moderate to severe defined as painful. We used multivariate logistic regression models to estimate ORs for painful colonoscopy and calculated risk-adjusted ratios of painful colonoscopies per endoscopist and compared it to the mean rate. RESULTS Of 35 216 screening colonoscopies in 2014 and 2015 included in our study, 22 725 (64.5%) patients returned valid Gastronet questionnaires. The proportion of examinations described as causing pain during (after) the procedure was 22.5% (14.2%) for unsedated, 19.9% (13.5%) for benzodiazepine-opioid sedation and 2.5% (7.5%) for propofol sedation. Propofol sedation, higher case volume of endoscopists, newest endoscope generation and adequate bowel preparation were significantly associated with lower odds of painful colonoscopy. Pain scores after colonoscopy showed similar associations. Adjusted pain rates during and after colonoscopy varied 11 and over 23-fold, respectively, between endoscopists. CONCLUSION We identified several independent, modifiable factors associated with pain during and after colonoscopy, of which individual endoscopist was the most important. Dedicated training should be considered to decrease variability among endoscopists.
Collapse
Affiliation(s)
- Marek Bugajski
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre, Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Oncology, Medical Center for Postgraduate Education, Warsaw, Poland
| | - Paulina Wieszczy
- Department of Gastroenterology, Hepatology and Oncology, Medical Center for Postgraduate Education, Warsaw, Poland.,Department of Cancer Prevention, The Maria Sklodowska-Curie Memorial Cancer Centre, Institute of Oncology, Warsaw, Poland
| | - Geir Hoff
- Department of Research and Development, Telemark Hospital, Skien, Norway.,Department of Health Management and Health Economics, University of Oslo, Oslo, Norway
| | - Maciej Rupinski
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre, Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Oncology, Medical Center for Postgraduate Education, Warsaw, Poland
| | - Jaroslaw Regula
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre, Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Oncology, Medical Center for Postgraduate Education, Warsaw, Poland
| | - Michal Filip Kaminski
- Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre, Institute of Oncology, Warsaw, Poland.,Department of Gastroenterology, Hepatology and Oncology, Medical Center for Postgraduate Education, Warsaw, Poland.,Department of Cancer Prevention, The Maria Sklodowska-Curie Memorial Cancer Centre, Institute of Oncology, Warsaw, Poland.,Department of Health Management and Health Economics, University of Oslo, Oslo, Norway
| |
Collapse
|
8
|
Sato K, Ito S, Kitagawa T, Hirahata K, Hihara D, Tominaga K, Yasuda I, Maetani I. A prospective randomized study of the use of an ultrathin colonoscope versus a pediatric colonoscope in sedation-optional colonoscopy. Surg Endosc 2017; 31:5150-5158. [PMID: 28488178 DOI: 10.1007/s00464-017-5581-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Accepted: 05/02/2017] [Indexed: 12/23/2022]
Abstract
BACKGROUND Ultrathin colonoscopes (UTC) reportedly produce less pain during colonoscopy than standard colonoscopes. The aim of this study was to assess the tolerability of an UTC compared with that of a pediatric colonoscope. METHODS A total of 270 adult patients scheduled to undergo colonoscopy were randomized, with 134 allocated to the UTC group and 136 to the pediatric colonoscope group. Pain was assessed using a visual analog scale. For all procedures, sedation was administered only if requested. Overall pain, rate and time of cecal and terminal ileum intubation, number of patients requesting sedation, adenoma detection rates (ADR), and rate of complications were measured and analyzed. RESULTS Among all patients, the medians of maximum pain and overall pain were significantly lower in the UTC group than in the pediatric colonoscope group (23 vs. 38, P < 0.001; 12 vs. 22, P = 0.0003, respectively). Significantly fewer patients requested sedation in the UTC group than in the pediatric colonoscope group (1.4 vs. 6.6%; P = 0.0269). No significant differences were seen in either the rate and time of successful cecal and terminal ileum intubation, or in other procedure-related outcomes, including ADR. CONCLUSIONS Compared with a pediatric colonoscope, the UTC was associated with reduced overall and maximum pain during colonoscopy, with no difference in ADR.
Collapse
Affiliation(s)
- Koichiro Sato
- Department of Gastroenterology, Mizonokuchi Hospital, Teikyo University School of Medicine, 3-8-3 Mizonokuchi, Takatsu-ku, Kawasaki, Kanagawa, 213-8507, Japan.
| | - Sayo Ito
- Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Tomoyuki Kitagawa
- Department of Gastroenterology, Dokkyo Medical University Koshigaya Hospital, 2-1-50 Minamikoshigaya, Koshigaya-Shi, Saitama Prefecture, Japan
| | | | - Daisuke Hihara
- Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Kenji Tominaga
- Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| | - Ichiro Yasuda
- Department of Gastroenterology, Mizonokuchi Hospital, Teikyo University School of Medicine, 3-8-3 Mizonokuchi, Takatsu-ku, Kawasaki, Kanagawa, 213-8507, Japan
| | - Iruru Maetani
- Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan
| |
Collapse
|
9
|
Nemoto D, Utano K, Endo S, Isohata N, Hewett DG, Togashi K. Ultrathin versus pediatric instruments for colonoscopy in older female patients: A randomized trial. Dig Endosc 2017; 29:168-174. [PMID: 27859645 DOI: 10.1111/den.12761] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Accepted: 11/07/2016] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIM Small-caliber endoscopes such as gastroscopes or pediatric colonoscopes are occasionally required to negotiate fixed or angulated colons. However, the use of a new ultrathin instrument (diameter 7.0 mm) narrower than other conventional colonoscopes has not been evaluated. The aim of the present study was to compare the use compare the use of an ultrathin colonoscope (UTC) with a pediatric colonoscope (PDC) for colonoscopy in older female patients. METHODS A prospective, randomized, controlled trial was conducted in a single academic endoscopy unit. A total of 77 female patients aged ≥70 years undergoing unsedated colonoscopy were randomized to colonoscopy with a UTC (n = 39) or PDC (n = 38). Primary outcome measurement was the degree of pain using a numerical rating scale, and secondary outcomes were cecal intubation rate, ileal intubation rate, time to cecum and adenoma detection rate. RESULTS There was a significant difference in reported pain using the numerical rating scale (median, UTC 1 vs PDC 4, P < 0.0001). Cecal intubation rates were 97.4% in UTC and 92.1% in PDC (P = 0.36), and ileal intubation rates were 82.0% and 89.4% (P = 0.76), respectively. However, median times to cecum were significantly longer using UTC compared with PDC (15.2 min vs 11.1 min, P = 0.022). Adenoma detection rates were 30.7% in UTC and 26.3% in PDC (P = 0.80). CONCLUSIONS Colonoscopy using UTC was almost equivalent to that of PDC in older female patients, with significantly less pain compared with PDC. UTC may be an alternative to PDC for the difficult colon.
Collapse
Affiliation(s)
- Daiki Nemoto
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu-City, Japan
| | - Kenichi Utano
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu-City, Japan
| | - Shungo Endo
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu-City, Japan
| | - Noriyuki Isohata
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu-City, Japan
| | - David G Hewett
- University of Queensland, School of Medicine, Brisbane, Australia
| | - Kazutomo Togashi
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu-City, Japan
| |
Collapse
|
10
|
Cologne KG, Bastawrous A. How to achieve cecal intubation in patients with angulated and redundant colons? SEMINARS IN COLON AND RECTAL SURGERY 2017. [DOI: 10.1053/j.scrs.2016.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Affiliation(s)
- Øyvind Holme
- Department of Medicine, Sørlandet Hospital, Kristiansand, Norway,Department of Health Management and Health Economics, University of Oslo, Oslo, Norway,Corresponding author Øyvind Holme, MD, PhD Sorlandet Hospital Kristiansand, Postbox 4164604 KristiansandNorway
| | - Michael Bretthauer
- Department of Medicine, Sørlandet Hospital, Kristiansand, Norway,Department of Health Management and Health Economics, University of Oslo, Oslo, Norway,Department of Transplantation Medicine and KG Jebsen Center for Coilorectakl Cancer Research, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
12
|
Chacko L, Macaron C, Burke CA. Colorectal cancer screening and prevention in women. Dig Dis Sci 2015; 60:698-710. [PMID: 25596719 DOI: 10.1007/s10620-014-3452-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2014] [Accepted: 11/16/2014] [Indexed: 02/07/2023]
Abstract
Colorectal cancer (CRC) is one of the leading cancers and cause of cancer deaths in American women and men. Females and males share a similar lifetime cumulative risk of CRC however, substantial differences in risk factors, tumor biology, and effectiveness of cancer prevention services have been observed between them. This review distills the evidence documenting the unique variation observed between the genders relating to CRC risk factors, screening and prevention. Consistent evidence throughout the world demonstrates that women reach equivalent levels of adenomas and CRC as men but it occurs nearly a decade later in life than in their male counterparts. Women have a higher proportion of tumors which are hypermethylated, have microsatellite instability and located in the proximal colon suggesting the serrated pathway may be of greater consequence in them than in men. Other CRC risk factors such as smoking, diet and obesity have been shown to have disparate effects on women which may related to interactions between estrogen exposure, body fat distribution, and the biologic underpinnings of their tumors. There is data showing the uptake, choice, and efficacy of different CRC screening methods in women is dissimilar to that in men. The mortality benefit from FOBT, sigmoidoscopy, and protection from interval CRC by colonoscopy appears to be lower in women than men. A greater understanding of these gender idiosyncrasies will facilitate an personalized approach to CRC prevention and should ultimately lead to a reduced burden of disease.
Collapse
Affiliation(s)
- Lyssa Chacko
- Department of Gastroenterology and Hepatology, Denver Veterans Affairs Medical Center, Denver, CO, USA
| | | | | |
Collapse
|
13
|
Sato K, Shigiyama F, Ito S, Kitagawa T, Tominaga K, Suzuki T, Maetani I. Colonoscopy using a small-caliber colonoscope with passive-bending after incomplete colonoscopy due to sharp angulation or pain. Surg Endosc 2013; 27:4171-6. [PMID: 23722893 DOI: 10.1007/s00464-013-3016-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Accepted: 05/04/2013] [Indexed: 02/07/2023]
Abstract
BACKGROUND We evaluated the performance of a newly developed small-caliber (SC) colonoscope (PCF-PQ260L). This colonoscope (diameter 9.2 mm) is designed with passive-bending and high-force transmission. The SC colonoscope was used for rescue colonoscopy following incomplete colonoscopy with a standard (SD) colonoscope caused by sharp angulation, loop formation, or pain. METHODS Records of SC colonoscopy given to patients following an incomplete colonoscopy with the SD colonoscope and in the same session were analyzed. Cecal intubation rate, pain using a visual analog scale (0 = none, 100 = extremely painful) in the first and second colonoscopy, total time, new lesions detected with the SC colonoscopy, dosage of sedation used, and any complications were assessed. Examinations that could not be completed, because the colonoscope was not long enough to reach the cecum due to a redundant colon were excluded. RESULTS The records of 43 patients who were given SC colonoscopy following incomplete examinations using the SD colonoscope were reviewed. In 97.7 % of cases (42/43), cecal intubation was achieved with the SC colonoscope in the same session. The mean pain score during colonoscopy was significantly lower for the second SC colonoscopy than for the first SD colonoscopy (40.6 ± 14.1 vs. 74.5 ± 10.8, P < 0.001). Lesions were detected with the SC colonoscope in 41.8 % of cases (18/43). CONCLUSIONS When a colonoscopy with SD colonoscope failed due to sharp angulations, loop formation, or pain, subsequent colonoscopy with a SC colonoscope increased cecal intubation and lesion detection rates and decreased severity of reported pain.
Collapse
Affiliation(s)
- Koichiro Sato
- Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan,
| | | | | | | | | | | | | |
Collapse
|
14
|
Dzeletovic I, Harrison ME, Pasha SF, Crowell MD, Decker GA, Gurudu SR, Leighton JA. Comparison of single- versus double-balloon assisted-colonoscopy for colon examination after previous incomplete standard colonoscopy. Dig Dis Sci 2012; 57:2680-6. [PMID: 22615017 DOI: 10.1007/s10620-012-2227-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2012] [Accepted: 04/30/2012] [Indexed: 02/06/2023]
Abstract
BACKGROUND Colonoscopy fails to achieve cecal intubation in 5-10 % of cases. Many of these cases can be completed using balloon-assisted colonoscopy, either with the single-balloon colonoscopy (SBC) or the double-balloon colonoscopy (DBC) techniques. AIM To compare the completion rates of SBC and DBC in patients with previous incomplete conventional colonoscopy. METHODS Between August 2009 and July 2011 either SBC or DBC was performed in 53 patients in whom previous conventional colonoscopy did not achieve cecal intubation. The medical records of these 53 patients were reviewed retrospectively for details regarding (1) indication for the initial colonoscopy, (2) patient characteristics, (3) data from the initial colonoscopy, and (4) details on both SBC and DBC. RESULTS SBC was successful in intubating the cecum in 100 % (26/26) of patients and DBC was successful in 93 % (25/27) of patients. The median (range) time to reach the cecum was 17 (9-43) min in the SBC group and 20 (7-58) min in the DBC group (P = 0.37). The presence of polyps was an entirely new finding in 35 % (9/26) of patients in the SBC group and 30 % (8/27) of patients in DBC group. Therapeutics were performed in 73 % (19/26) of patients in SBC group and 67 % (18/27) of patients in DBC group. CONCLUSION For patients with incomplete conventional colonoscopy, SBC and DBC offer high cecal intubation rates as well as detection of additional polyps and therapeutic capability. Either SBC or DBC can be considered after incomplete conventional colonoscopy.
Collapse
Affiliation(s)
- Ivana Dzeletovic
- Division of Gastroenterology and Hepatology, Mayo Clinic, 13400 East Shea Boulevard, Scottsdale, AZ 85259, USA.
| | | | | | | | | | | | | |
Collapse
|
15
|
Mizukami T, Ogata H, Hibi T. “Passive-bending colonoscope” significantly improves cecal intubation in difficult cases. World J Gastroenterol 2012; 18:4454-6. [PMID: 22969214 PMCID: PMC3436066 DOI: 10.3748/wjg.v18.i32.4454] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2012] [Revised: 07/20/2012] [Accepted: 07/28/2012] [Indexed: 02/06/2023] Open
Abstract
Colonoscopy sometimes causes pain during insertion, especially in difficult cases. Over-insufflation of air causes elongation or acute angulations of the colon, making passage of the scope difficult and causing pain. We previously reported a sedative-risk-free colonoscopy insertion technique, namely, “Water Navigation Colonoscopy”. Complete air suction after water infusion not only improves the vision, but also makes water flow down to the descending colon, while the sigmoid colon collapses and shortens. While non-sedative colonoscopy can be carried out without pain in most cases, some patients do complain of pain. Most of these patients have abnormal colon morphology, and the pain is caused while negotiating the “hairpin” bends of the colon. The “hairpin” bends of the colon should be negotiated by gently pushing the full-angled colonoscope. The proximal 10-20 cm from the angulated part of the conventional colonoscope is stiff, with a wide turning radius, therefore, a conventional colonoscope cannot be negotiated through the “hairpin” bends of the colon without stretching them and causing pain. The “passive-bending colonoscope” has a flexible tip with a narrow turning radius, so that the scope can be negotiated through the “hairpin” bends of the colon with a minimum turning radius and minimal discomfort. Therefore, the intubation and pain-reducing performance of the “passive-bending colonoscope” was assessed in difficult cases.
Collapse
|
16
|
Jung Y, Lee SH. How do I overcome difficulties in insertion? Clin Endosc 2012; 45:278-81. [PMID: 22977817 PMCID: PMC3429751 DOI: 10.5946/ce.2012.45.3.278] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2012] [Revised: 07/27/2012] [Accepted: 07/27/2012] [Indexed: 12/25/2022] Open
Abstract
Demand for colonoscopy is increasing because it is an important tool not only for screening of colorectal neoplasm but also for resection of such lesions in early stage. Cecal intubation requires expertise on shortening of the examination time and improvement of the cecal intubation rate without causing pain to the patients. About 5% to 10% of patients still experience difficulties or failure of the cecal intubation. There are number of factors that affect the difficulty of the colonoscopy such as technical skill of the endoscopist, angulated sigmoid, redundant colon, advanced age, female gender, diverticular disease, and inadequate bowel preparation. In an effort to overcome these situations and to and aiding colonoscope insertion with reducing pain, various methods have introduced. Like this review discusses ways to approach patients with technically difficult colons for achieving the successful cecal intubation.
Collapse
Affiliation(s)
- Yunho Jung
- Department of Internal Medicine, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
| | | |
Collapse
|
17
|
Koumi A, Kalaitzakis E, Forbes A, Panos MZ. Underutilisation of the gastroscope for total colonoscopy in adults: a survey of two European countries. Int J Colorectal Dis 2012; 27:959-65. [PMID: 22395658 DOI: 10.1007/s00384-012-1436-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/09/2012] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND STUDY AIMS High caecal intubation success rates have been reported with the gastroscope in adults. We surveyed the current use of the gastroscope for total colonoscopy in adults in the UK and Greece. METHODS A questionnaire was e-mailed to 952 members of the British Society of Gastroenterology (UK) and 478 members of the Hellenic Society of Gastroenterology (GR), enquiring as to access to a paediatric colonoscope, use of gastroscope for total colonoscopy and estimate of caecal intubation success rate. RESULTS Valid replies were 17.4% from UK and 19.7% from GR. The paediatric colonoscope was available to 106/138 (77%) UK and to only 18/86 (21%) GR respondents (p = 0.0002). Of all the UK and GR respondents, 109/138 (79%) and 68/86 (79%), respectively, did not use the gastroscope for total colonoscopy. For the use of the gastroscope for total colonoscopy, 26/29 (89%) UK and 9/18 (50%) GR users did so, while a paediatric colonoscope was also available (p = 0.001), and 3/29 (10.3%) UK and 9/18 (50%) GR users did so, whilst they had no access to a paediatric colonoscope (p = 0.001). Estimated gastroscope caecal intubation success rate was 69% (SD 0.26) UK and 46% (SD 0.36) GR, p = 0.008. Only 37% UK and 28% GR respondents used the gastroscope to examine the left colon. CONCLUSIONS The gastroscope is underutilised for total colonoscopy in both the UK and Greece. Use of the gastroscope does not appear to be related to lack of access to a paediatric colonoscope in the UK but may be in GR. Gastroscope caecal intubation success rate justifies its use where the colonoscope fails.
Collapse
Affiliation(s)
- Andriani Koumi
- Department of Gastroenterology, Euroclinic of Athens, 9 Athanasiadou Street, 11521 Athens, Greece
| | | | | | | |
Collapse
|
18
|
Ultrathin-caliber colonoscopy: is thin truly in? Gastrointest Endosc 2012; 75:491-3. [PMID: 22341097 DOI: 10.1016/j.gie.2011.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Accepted: 09/01/2011] [Indexed: 01/12/2023]
|
19
|
Abstract
Although colonoscopy is a very commonly carried out procedure, it is not without its problems, including a risk of perforation and significant patient discomfort, especially associated with looping formation. Furthermore, looping formation may prevent a complete colonoscopy from being carried out in certain patients. The conventional colonoscope has not changed very much since its original introduction. We review promising technologies that are being promoted as a way to address the problems with current colonoscopy. There are some methods to prevent looping formation, including overtube, variable stiffness, computer-guided scopes, Aer-O-Scope, magnetic endoscopic imaging and the capsule endoscope. In recent years, with the progress of microelectromechanical and microelectronic technologies, many biomedical and robotic researchers are developing autonomous endoscopes with miniaturization of size and integration functionality that represent state of the art of the micro-robotic endoscope. The initial results by using aforementioned methods seem promising; however, there are some conflicting reports of clinical trials with the overtube colonoscope, the computer-guided scope and the variable stiffness colonoscope. There are also some limitations in the use of the Aer-o-scope and the capsule endoscope. The autonomous endoscope is based on a self-propelling property that is able to avoid looping completely. This novel technology could potentially become the next generation endoscope; however, there are still critical techniques to be approached in order to develop the effective and efficient novel endoscope.
Collapse
Affiliation(s)
- Wu Bin Cheng
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, Canada
| | | | | | | |
Collapse
|
20
|
Raju GS, Saito Y, Matsuda T, Kaltenbach T, Soetikno R. Endoscopic management of colonoscopic perforations (with videos). Gastrointest Endosc 2011; 74:1380-8. [PMID: 22136781 DOI: 10.1016/j.gie.2011.08.007] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2011] [Accepted: 08/04/2011] [Indexed: 02/08/2023]
Affiliation(s)
- Gottumukkala S Raju
- Department of Gastroenterology, Hepatology, and Nutrition, University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | | | | | | | | |
Collapse
|
21
|
Abstract
Colonoscopy is considered the 'gold standard' for detection and removal of premalignant lesions in the colon. However, studies suggest that colonoscopy is less protective for right-sided than for left-sided colorectal cancer. Optimizing the effectiveness of colonoscopy is a continuous process, and during the past decade several important quality indicators have been defined that can be used to measure the performance of colonoscopy and to identify areas for quality improvement. The quality of bowel preparation can be enhanced by split-dose regimens, which are superior to single-dose regimens. Cecal intubation rates should approximate 95% and can be optimized by good technique. In selected patients, specific devices can be used to facilitate cecal intubation. Adenoma detection rates should be monitored and exceed a minimum of 25% in men and 15% in women. To this aim, optimal withdrawal technique and adequate time for inspection are of utmost importance. Of all advanced imaging techniques, chromoendoscopy is the only technique with proven benefit for adenoma detection. Finally, the technique of polypectomy affects the number of complications as well as the success of completely removing a lesion. In this Review, we provide an overview of both standard and novel colonoscopy techniques and their impact on quality indicators.
Collapse
Affiliation(s)
- Yark Hazewinkel
- Department of Gastroenterology and Hepatology, Academic Medical Center, University of Amsterdam, PO Box 22700, Meibergdreef 9, Amsterdam, 1105 AZ, The Netherlands
| | | |
Collapse
|
22
|
Krishnan S, Wolf JL. Colorectal cancer screening and prevention in women. ACTA ACUST UNITED AC 2011; 7:213-26. [PMID: 21410347 DOI: 10.2217/whe.11.7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Colorectal cancer (CRC) is the third most common cause of cancer in women. Screening for CRC increases early detection of cancer and premalignant polyps and decreases morbidity from this disease. However, adherence to the screening guidelines continues to remain inadequate both at the physician and patient levels. Several factors are of special importance to women. Presence of prior gynecological malignancies may increase the risk of CRC in women. Furthermore, new studies have shown other factors such as obesity and smoking to increase the risk of CRC in women. This article highlights issues unique to women with regards to CRC and outlines special considerations for determining screening intervals in women, identifies factors that make screening more difficult in women, and reviews studies that identify preventative strategies which, together with screening, may reduce the burden of CRC.
Collapse
Affiliation(s)
- Sandeep Krishnan
- Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, USA
| | | |
Collapse
|
23
|
Abstract
The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2010 for articles related to endoscopy by using the key words "gastroscope," "colonoscope," "echoendoscope," "duodenoscope," "choledochoscope," "ultraslim endoscope," "variable stiffness colonoscope," and "wide-angle colonoscope." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.
Collapse
|
24
|
Jimenez B, Palekar N, Schneider A. Issues related to colorectal cancer and colorectal cancer screening practices in women. Gastroenterol Clin North Am 2011; 40:415-26, ix. [PMID: 21601788 DOI: 10.1016/j.gtc.2011.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
Studies have shown that colorectal cancer (CRC) incidence is equal between men and women. However, several studies have demonstrated lower adenoma detection rates in women than in men. Many questions arise about differences in adenomas, CRC, and screening practices between men and women: should screening be the same for both sexes, are there differences in risk factors in the formation of colon cancer, should special groups of women be screened differently from the general population, are colonoscopies tolerated differently in women and why, and what determines if a woman will undergo colonoscopy? This article reviews these issues.
Collapse
Affiliation(s)
- Brenda Jimenez
- Department of Gastroenterology and Hepatology, Cleveland Clinic Florida, 2950 Cleveland Clinic Boulevard, Weston, FL 33331, USA.
| | | | | |
Collapse
|
25
|
Abstract
The colonoscopic insertion technique is still one of the most difficult endoscopic procedures to master and development of a new colonoscope that is easier to insert is much awaited especially into the cecum without patient discomfort. We focused on reducing patient pain and boosting the success rate of colonoscope insertion into the cecum in complicated cases. As a result, we have successfully developed two mechanisms: "Passive Bending" and use of a "High Force Transmission insertion tube." We believe these two mechanisms when combined together will contribute to a reduction in patient discomfort and an increase in the cecal intubation rate during many difficult colonoscopies, but further evaluation is required with respect to therapeutic endoscopy effectiveness and insertion for patients with long colons.
Collapse
Affiliation(s)
- Yutaka Saito
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.
| | | |
Collapse
|
26
|
Athreya PJ, Owen GN, Wong SW, Douglas PR, Newstead GL. Achieving quality in colonoscopy: bowel preparation timing and colon cleanliness. ANZ J Surg 2010; 81:261-5. [DOI: 10.1111/j.1445-2197.2010.05429.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
27
|
Garrett KA, Church J. History of hysterectomy: a significant problem for colonoscopists that is not present in patients who have had sigmoid colectomy. Dis Colon Rectum 2010; 53:1055-60. [PMID: 20551759 DOI: 10.1007/dcr.0b013e3181d569cc] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
PURPOSE During colonoscopy, it is often difficult to traverse the sigmoid colon in patients who have had a hysterectomy, presumably due to postsurgical pelvic adhesions. We performed this study to document this difficulty and to determine whether sigmoid colectomy prevents it. METHODS Data were acquired from a single endoscopist's prospective database. Colonoscopies performed in women were grouped according to history of hysterectomy and/or sigmoid colectomy. Groups were compared for colonoscopy completion rate, medication used, and time of examination. Participation of fellows and rate of complications were recorded. Patients with a history of abdominal-perineal resection of the rectum were excluded. RESULTS From 1989 to 2006, a total of 4116 colonoscopies were performed in women: 993 had undergone hysterectomy (24.1%), of whom 108 (10.9%) had also undergone sigmoid colectomy. There were 3123 exams in woman who had their uterus (75.9%); 320 (10.2%) had undergone sigmoid colectomy. Patients who still had a sigmoid colon but had a history of hysterectomy had significantly lower colonoscopy completion rates (89.2%) and significantly longer mean examination time (28.9 +/- 12.3 minutes), and more of them required sedation with benzodiazepines (88.7%) than the other groups (P < .05). Fellow participation increased time of colonoscopy and complications were more frequent in patients with hysterectomy. CONCLUSION Posthysterectomy adhesions to the sigmoid colon make colonoscopy more difficult and more painful. These adverse effects are not present in hysterectomized women who have undergone sigmoid resection.
Collapse
Affiliation(s)
- Kelly A Garrett
- Department of Colorectal Surgery, Digestive Diseases Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | | |
Collapse
|
28
|
Dib J, Díaz S, Ortiz A, Bastardo N. Use of a standard gastroscope for colonoscopy at a general hospital in Venezuela: A prospective randomized trial. Arab J Gastroenterol 2010. [DOI: 10.1016/j.ajg.2010.01.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
29
|
Uraoka T, Kato J, Kuriyama M, Hori K, Ishikawa S, Harada K, Takemoto K, Hiraoka S, Fujita H, Horii J, Saito Y, Yamamoto K. CO 2 insufflation for potentially difficult colonoscopies: Efficacy when used by less experienced colonoscopists. World J Gastroenterol 2009; 15:5186-92. [PMID: 19891018 PMCID: PMC2773898 DOI: 10.3748/wjg.15.5186] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
AIM: To clarify the effectiveness of CO2 insufflation in potentially difficult colonoscopy cases, particularly in relation to the experience level of colonoscopists.
METHODS: One hundred twenty potentially difficult cases were included in this study, which involved females with a low body mass index and patients with earlier abdominal and/or pelvic open surgery or previously diagnosed left-side colon diverticulosis. Patients receiving colonoscopy examinations without sedation using a pediatric variable-stiffness colonoscope were divided into two groups based on either CO2 or standard air insufflation. Both insufflation procedures were also evaluated according to the experience level of the respective colonoscopists who were divided into an experienced colonoscopist (EC) group and a less experienced colonoscopist (LEC) group. Study measurements included a 100-mm visual analogue scale (VAS) for patient pain during and after colonoscopy examinations, in addition to insertion to the cecum and withdrawal times.
RESULTS: Examination times did not differ, however, VAS scores in the CO2 group were significantly better than in the air group (P < 0.001, two-way ANOVA) from immediately after the procedure and up to 2 h later. There were no significant differences between either insufflation method in the EC group (P = 0.29), however, VAS scores for CO2 insufflation were significantly better than air insufflation in the LEC group (P = 0.023) immediately after colonoscopies and up to 4 h afterwards.
CONCLUSION: CO2 insufflation reduced patient pain after colonoscopy in potentially difficult cases when performed by LECs.
Collapse
|
30
|
Hsieh YH, Zhou AL, Lin HJ. Long pediatric colonoscope versus intermediate length adult colonoscope for colonoscopy. J Gastroenterol Hepatol 2008; 23:e7-e10. [PMID: 18702687 DOI: 10.1111/j.1440-1746.2007.04864.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
BACKGROUND Controversy exists on how the length and diameter of colonoscopes affect the quality of colonoscopy. The aim of this study was to compare a long pediatric colonoscope with an intermediate length adult colonoscope with regards to completion rate and cecal intubation time. Whether either scope may be more efficient in any subgroups was also investigated. METHODS Asymptomatic patients admitted to the physical check-up department of Buddhist Dalin Tzu Chi General Hospital were included. A single endoscopist performed all of the colonoscopic examinations under sedation. Consecutive patients were randomized to undergo colonoscopy with either intermediate length adult colonoscope (CF-240I) or long pediatric colonoscope (PCF-240L). The success rate and time required to reach cecum were compared between the two groups. RESULTS Between April 2005 and February 2006, a total of 918 patients were enrolled. Incomplete colonoscopy occurred in 21 (2.3%) cases (14 in the CF-240I group and seven in the PCF-240L group, P > 0.1). The overall cecal mean insertion time was 6.00 +/- 3.66 min. There was no significant difference between the CF-240I and PCF 240L groups with regard to the cecal intubation rate (96.9% vs 98.5%, P = 0.18), the need for abdominal pressure (71.7% vs 73.4%, P = 0.55) and change of position (13.5% vs 11.5%, P = 0.37). However, the cecal intubation time was shorter in the CF-240I group (5.75 +/- 3.18 vs 6.26 +/- 3.30 min, P = 0.02). Subgroup analysis by sex, age, and body mass index showed comparable outcomes between the two groups except that the cecal intubation times were significantly shorter in the CF-240I group when only men (4.78 +/- 2.57 vs 5.50 +/- 2.93 min, P < 0.01) or those younger than 50 years (5.50 +/- 2.90 vs 6.25 +/- 3.68 min, P = 0.02) were considered. CONCLUSION Cecal intubation time is shorter in patients examined with an intermediate length adult colonoscope, mainly in the subgroups of men and those younger than 50 years of age.
Collapse
Affiliation(s)
- Yu-Hsi Hsieh
- Department of Medicine, Division of Gastroenterology, Buddhist Dalin Tzu Chi General Hospital, Chia-Yi, Taiwan.
| | | | | |
Collapse
|
31
|
Chen PJ, Shih YL, Chu HC, Chang WK, Hsieh TY, Chao YC. A prospective trial of variable stiffness colonoscopes with different tip diameters in unsedated patients. Am J Gastroenterol 2008; 103:1365-71. [PMID: 18513270 DOI: 10.1111/j.1572-0241.2008.01812.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Few data exist comparing the clinical versatility of variable stiffness (VS) colonoscopes with different tip diameters and stiffness ranges. We compared the intubation time and success rate, maneuvering ease, and patient comfort of three colonoscopes: pediatric VS (PVSC), nonmagnifying adult VS (AVSC), and magnifying VS (MVSC). METHODS Two hundred sixteen consecutive patients scheduled for routine colonoscopy were randomized to undergo colonoscopy with one of the three different colonoscopes (PVSC N = 72, AVSC N = 72, MVSC N = 72). Outcome measurements included time required for cecal intubation, success rate for cecal intubation, maneuvering ease, and patient comfort. RESULTS The overall success rate for cecal intubation was 95.83%. Intubation time was significantly different among the groups (PVSC 12.88 +/- 7.11 min, AVSC 9.25 +/- 5.16 min, MVSC 9.62 +/- 5.55 min; P < 0.01). Intubation time with PVSC required about 3 min more when compared with AVSC or MVSC. Multivariate analyses revealed that colonoscopy with AVSC required 3 min less when compared with PVSC (P= 0.03). Age greater than 55 yr, waist circumference, prior hysterectomy, and pain experienced by patients were also factors affecting intubation time. CONCLUSIONS In this study, a PVSC might not decrease patient discomfort or intubation time. The ideal colonoscope is the AVSC that has a modest diameter and stiffness range and thus is capable of achieving both a short intubation time and an acceptable comfort level. We also should bear in mind that MVSC has an additional function of magnifying observation.
Collapse
Affiliation(s)
- Peng-Jen Chen
- Division of Gastroenterology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan
| | | | | | | | | | | |
Collapse
|
32
|
Hsieh YH, Zhou AL, Lin HJ. Comparing different methods of activating the variable stiffness function of a pediatric variable stiffness colonoscope. J Chin Med Assoc 2008; 71:23-9. [PMID: 18218556 DOI: 10.1016/s1726-4901(08)70068-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Previous studies on variable stiffness colonoscopes showed mixed results. Different methods of activating the variable stiffness function were used and might explain part of the controversy. To determine the most efficient way of activating the variable stiffness function, this study compared 3 methods (no activation, regular activation, activation on an as-needed basis) using 1 single type of pediatric variable stiffness colonoscope. METHODS Asymptomatic patients admitted for physical check-up at the Buddhist Dalin Tzu Chi General Hospital were included. A single endoscopist performed all of the colonoscopic examinations of patients under sedation using a variable stiffness pediatric colonoscope. Consecutive patients were randomized to undergo colonoscopy using 3 different methods of activating the variable stiffness function: no activation ("no" group), regular activation at descending colon ("regular" group), and activation on an as-needed basis ("as-needed" group). Completion rate, cecal intubation time, and use of adjunct measures were evaluated and compared among the 3 groups. Subgroup analysis by gender was also performed. RESULTS Between January and July 2006, a total of 250 patients were enrolled. The completion rates of the examinations were 97.6%, 91.7% and 96.4% in the no, regular and as-needed groups, respectively (p = 0.17). The cecal intubation times were 5.6 +/- 2.6 minutes, 5.6 +/- 2.7 minutes and 6.2 +/- 2.3 minutes, respectively (p = 0.22). Multivariate logistic regression analysis showed that activation of the variable stiffness function regularly (odds ratio [OR], 0.53; 95% confidence interval [CI], 0.28, 0.98; p = 0.04) or on an as-needed basis (OR, 0.52; 95% CI, 0.28, 0.97; p = 0.04) were independent factors that were related with less use of abdominal pressure. When only women were considered, the completion rate was lower in the regular group (98.0%, 86.8% and 96.5%, p = 0.04). The use of abdominal pressure was more in the no group than the other 2 groups (56%, 34% and 33%, p = 0.03). When only men were considered, the cecal intubation time was longer in the as-needed group (4.6 +/- 1.4, 4.6 +/- 1.8 and 5.8 +/- 2.5 minutes, p = 0.02). The other outcomes were similar in both genders. CONCLUSION The 3 different methods did not result in significantly different completion rates or cecal intubation times. However, activation of the variable stiffness function decreased the need for abdominal pressure. When males and females were considered separately, activation of the variable stiffness function on an as-needed basis in females was the only useful setting.
Collapse
Affiliation(s)
- Yu-Hsi Hsieh
- Department of Medicine, Buddhist Dalin Tzu Chi General Hospital, Chia-Yi, Taiwan
| | | | | |
Collapse
|
33
|
Fincher RK, Myers J, McNear S, Liveringhouse JD, Topolski RL, McNear J. Comfort and efficacy of a longer and thinner endoscope for average risk colon cancer screening. Dig Dis Sci 2007; 52:2892-6. [PMID: 17394073 DOI: 10.1007/s10620-006-9642-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2006] [Accepted: 10/09/2006] [Indexed: 12/09/2022]
Abstract
The aim of this prospective study was to assess patient comfort during nonsedated screening sigmoidoscopy with the use of a standard 60-cm sigmoidoscope compared with a thinner 100-cm upper endoscope. Patients undergoing routine colon cancer screening with sigmoidoscopy were randomly assigned to either a 60-cm sigmoidoscope or a 100-cm upper endoscope. The procedure time, depth of insertion, anatomic landmarks, and presence of polyps were documented. Likert 7-point scales and visual analog scales (VAS) were performed to measure comfort and symptoms immediately after the procedure and again in 1 week. These scales, procedure time, insertion depth, percent reaching transverse colon, and percent with polyps were analyzed. Eighty-one patients were enrolled with 38 in the 100-cm group and 43 in the 60-cm group. Patients in the 100-cm group reported greater comfort on the VAS compared with the 60-cm group (P = .035) as well as less cramping on the initial Likert scale (P = .017). One week later, the 100-cm group reported higher comfort (P = .015) and less bloating (P = .040). Procedure time was longer for the 100-cm group (8.8 versus 5.9 minutes; P = .001). Insertion depth was 74 versus 56 cm (P = .001), and percent reaching splenic flexure was 76% versus 35% (P = .001) in the 100 and 60 cm groups, respectively. More adenomas were found with the 100-cm scope (P = .035). The use of a thinner and longer endoscope is more comfortable than a standard sigmoidoscope. Although a 100-cm endoscope procedure takes longer to perform, it allows better evaluation of the colon and misses fewer adenomas.
Collapse
Affiliation(s)
- R Keith Fincher
- D.D. Eisenhower Army Medical Center, Fort Gordon, Georgia 30905, USA
| | | | | | | | | | | |
Collapse
|
34
|
Anderson JC, Walker G, Birk JW, Alpern Z, Von Althen I. Tapered colonoscope performs better than the pediatric colonoscope in female patients: a direct comparison through tandem colonoscopy. Gastrointest Endosc 2007; 65:1042-7. [PMID: 17331512 DOI: 10.1016/j.gie.2006.06.084] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2006] [Accepted: 06/30/2006] [Indexed: 02/08/2023]
Abstract
BACKGROUND The pediatric variable-stiffness colonoscope (PVSC) is used by many endoscopists to negotiate the colon that requires a flexible colonoscope; it has a smaller diameter, but may lead to excessive looping. A prototype colonoscope tapers from an adult width to a pediatric diameter at approximately 25 cm. The tapered colonoscope (TC), while retaining the flexibility of the PVSC, has the column strength of the adult colonoscope to help negotiate the proximal colon. OBJECTIVE Our hypothesis is that use of the TC in female patients would be associated with less looping than the PVSC during the procedure, fewer required maneuvers, and thus a quicker examination. DESIGN Direct comparison through tandem colonoscopies. SETTING University endoscopy suite. PATIENTS Forty unselected female patients. INTERVENTIONS Tandem colonoscopies with PVSC and TC. MAIN OUTCOME MEASUREMENTS Time to the cecum and the ability to retroflex in the cecum. RESULTS Compared with the PVSC, the TC had faster times to achieve cecal intubation (mean [standard deviation], 8.83+/-4.68 minutes versus 6.88+/-4.08 minutes; P=.013) and a higher rate of retroflexion in the cecum (31/40 patients vs 39/40 patients; P<.01). Use of the TC was associated with a decreased need for abdominal pressure (P<.001). CONCLUSIONS The TC achieved faster cecal intubation rates and had a higher success of cecal retroflexion than a PVSC. This performance likely was because of diminished looping and thus a decreased need for maneuvers. The TC may be preferable to the PVSC for female patients.
Collapse
Affiliation(s)
- Joseph C Anderson
- Department of Gastroenterology and Hepatology, Health Science Center, Stony Brook University, Stony Brook, New York 11794-8173, USA
| | | | | | | | | |
Collapse
|
35
|
Streett SE. Endoscopic colorectal cancer screening in women: can we do better? Gastrointest Endosc 2007; 65:1047-9. [PMID: 17531639 DOI: 10.1016/j.gie.2007.02.037] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2007] [Accepted: 02/17/2007] [Indexed: 02/08/2023]
|
36
|
Abstract
In up to 10% to 20% of colonoscopies, complete intubation of the colon may be considerably difficult. A principal cause of difficulty is looping of the endoscope shaft in a floppy, often tortuous segment of the colon that typically happens in the sigmoid colon. Also, if looping is not recognized and the scope is advanced with abandon, the risk of perforation will rise. Special "variable stiffness" colonoscopies are expensive and have not been unequivocally shown to be useful in preventing looping. The simplest approach to prevent looping is perhaps the use of an over-tube to prevent the shaft from bowing out. The ShapeLock could offer an ideal over-tube that is flexible enough to safely and easily negotiate bends in the colon but when needed be rigid enough to prevent looping with just a snap of its handle. It also has potential other applications including enteroscopy, transgastric endoscopy and access to difficult regions of the upper gastrointestinal tract.
Collapse
Affiliation(s)
- Rami Hawari
- Division of Gastroenterology and Hepatology, University of Texas Medical Branch 4.106 McCullough Building, 301 University Boulevard, Galveston, TX 77555-0764, USA
| | | |
Collapse
|
37
|
Abstract
Colorectal cancer (CRC) is the third most common cause of cancer in women. Screening has been shown to increase detection and decrease morbidity from this disease, but compliance is poor. This paper reviews special considerations for determining screening intervals in women, factors making screening more difficult in women, and studies reviewing preventative strategies in addition to screening that may reduce CRC.
Collapse
Affiliation(s)
- Jacqueline L Wolf
- Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02215, USA
| |
Collapse
|
38
|
Sanaka MR, Shah N, Mullen KD, Ferguson DR, Thomas C, McCullough AJ. Afternoon colonoscopies have higher failure rates than morning colonoscopies. Am J Gastroenterol 2006; 101:2726-30. [PMID: 17227519 DOI: 10.1111/j.1572-0241.2006.00887.x] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND There are several known predictors of an incomplete colonoscopy or difficult colonoscopy. In addition, inadequate bowel preparation has been reported in procedures scheduled later in the day. Operator fatigue, which tends to be higher as the day passes on, may also impact colonoscopy completion rate. AIMS To determine the influence of performing outpatient colonoscopies in the afternoon versus morning on the completion rates of colonoscopy and adequacy of bowel preparation. METHODS Retrospective chart review of all outpatient colonoscopies performed between November 2003 and October 2004 in the Division of Gastroenterology at MetroHealth Medical Center in Cleveland, Ohio. Patient demographics, indications for procedure, and colonoscopic findings were reviewed. Patients received polyethylene glycol electrolyte-based bowel preparation in the evening prior to the day of the scheduled colonoscopy. RESULTS A total of 2,087 colonoscopies was performed, of which 1,084 were in the morning and 999 were in the afternoon. Patients in the morning and afternoon were similar in regards to the known risk factors predictive of an incomplete colonoscopy. The incompletion rate was significantly higher in the afternoon compared to the morning (6.5% vs 4.1%, P= 0.013, OR for incompletion was 1.64, CI 1.11-2.44). Inadequate bowel preparation was found in 167 out of 1,084 (15.4%) colonoscopies in the morning and 197 out of 999 (19.7%) colonoscopies in the afternoon (P= 0.011). Even after excluding incomplete colonoscopies due to poor bowel preparation precluding examination, the incompletion rate was still higher in the afternoon (5% vs 3.2%, P= 0.043, OR 1.60, CI 1.03-2.51). CONCLUSIONS Scheduling of colonoscopies in the afternoon compared to the morning may be an independent predictor of an incomplete colonoscopy and inadequate bowel preparation. According to our study findings, scheduling of all outpatient colonoscopies preferentially in the morning would avoid suboptimal procedures in 5% of patients and the need for unnecessary repeat colonoscopy or an alternative imaging study in 2.4% of patients.
Collapse
Affiliation(s)
- Madhusudhan R Sanaka
- Division of Gastroenterology, MetroHealth Medical Center, Cleveland, Ohio 44109, USA
| | | | | | | | | | | |
Collapse
|
39
|
Abstract
Colonoscopy is the preferred method of screening for colorectal cancer in women. The longer, more redundant female colon is frequently more difficult for the endoscopist to navigate and most studies show longer insertion times, lower completion rates, and more discomfort associated with the procedure in women, all of which may be exacerbated by hysterectomy. To improve female patients' compliance with colorectal cancer screening we need to understand the barriers to participation prevalent among women. This article reviews the findings of several studies and discusses some steps to improve cancer screening for women.
Collapse
Affiliation(s)
- Robynne Chutkan
- Georgetown University Hospital, Division of Gastroenterology, Washington, DC 20007, USA.
| |
Collapse
|
40
|
Okamoto M, Kawabe T, Kato J, Yamaji Y, Ikenoue T, Omata M. Ultrathin colonoscope with a diameter of 9.8 mm for total colonoscopy. J Clin Gastroenterol 2005; 39:679-83. [PMID: 16082276 DOI: 10.1097/01.mcg.0000173859.31348.67] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
BACKGROUND The pediatric colonoscope is superior to the standard colonoscope in some patients with a fixed, angulated colon. A colonoscope thinner than the pediatric one is thought to outperform even the pediatric colonoscope in such cases. This study was conducted to assess the efficacy of an ultrathin colonoscope, 9.8 mm in diameter, comparing it with pediatric and standard colonoscopes. METHODS Three types of colonoscopes were used: ultrathin, pediatric, and standard. A total of 287 consecutive patients were assigned to three groups: ultrathin (n=94), pediatric (n=98), and standard (n=95). First assessment was the ratio of cecal intubation and the reasons for unsuccessful colonoscopy. The second was the time to cecal intubation. RESULTS Cecal intubation rates were not different among three groups (96% in each). The main reasons for failed colonoscopy were looping in the ultrathin group, and angulation or stricture in the pediatric and standard groups. Mean time to the cecum was slightly longer in the ultrathin group (6.5 minutes) than the pediatric group (5.6 minutes) and standard group (6.1 minutes), but there were no significant differences among three groups. CONCLUSION Colonoscopy with the ultrathin colonoscope was as successful as with the pediatric and standard colonoscopes. The advantage of the ultrathin colonoscope might be notable in cases with stricture or severe angulation.
Collapse
Affiliation(s)
- Makoto Okamoto
- Department of Gastroenterology, University of Tokyo, Tokyo, Japan.
| | | | | | | | | | | |
Collapse
|
41
|
Abstract
Colonoscopy has been available since the early 1970s and has become critical to the diagnosis and management of colorectal disorders. Features of the modern colonoscope and its variants are discussed, including the role of paediatric and variable stiffness colonoscopes for difficult insertion. The place of magnetic endoscope imaging systems and simulators in routine colonoscopy and training are examined. Finally, several recent innovations are used to illustrate how colonoscopy may evolve in the future, including new takes on the current instrument as well as potentially revolutionary pain-free, technically-easy, robotic devices for examination of the bowel.
Collapse
|
42
|
Abstract
PURPOSE Reports of virtual colonoscopy demonstrate sensitivity similar to that of conventional colonoscopy for polyps 5 mm or larger, suggesting the validity of its use for colorectal cancer screening. Critical to the success of either procedure is the ability to evaluate the entire colon. Cecal intubation rates during diagnostic or screening colonoscopies vary from 53 to 99 percent. We describe the added value of using a gastroscope to perform a colonoscopic examination that would otherwise result in an incomplete colonoscopy. METHODS From January 1, 2002 to December 31, 2002 a total of 1,979 colonoscopies were performed. A gastroscope was used in 1.3 percent (n = 26) of these colonoscopies in an effort to complete the index examination initially started with a standard or pediatric colonoscope. The success rate was defined as intubating proximal to the initial area of impasse and entering the cecum. RESULTS Cecal intubation was achieved in 62 percent of patients. CONCLUSIONS In patients with incomplete conventional colonoscopy, the gastroscope can usually advance through the initial area of impasse with a cecal intubation rate of 62 percent.
Collapse
Affiliation(s)
- Nina J Paonessa
- Division of Colon and Rectal Surgery, Lehigh Valley Hospital, Allentown, Pennsylvania 18105-1556, USA
| | | | | |
Collapse
|
43
|
Farraye FA, Horton K, Hersey H, Trnka Y, Heeren T, Provenzale D. Screening flexible sigmoidoscopy using an upper endoscope is better tolerated by women. Am J Gastroenterol 2004; 99:1074-80. [PMID: 15180728 DOI: 10.1111/j.1572-0241.2004.30215.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Flexible sigmoidoscopy (FS) is a commonly used method for colorectal cancer screening. Women are more likely than men to have a FS with a limited depth of insertion, in part due to differences of anatomy and perception of pain. AIM The objective of this prospective single-blinded randomized clinical study is to assess satisfaction in women undergoing screening FS using an upper endoscope (E, diameter 9.8 mm) versus a standard sigmoidoscope (S, diameter 13.3 mm) as measured by pain and discomfort and overall satisfaction using a validated survey instrument. Secondary endpoints of FS efficacy included the depth of insertion of the instrument, frequency of polyp detection, and complication rate. RESULTS A total of 160 asymptomatic women undergoing screening FS were entered over a 4-month period (July through November 2002). All procedures were performed by two experienced physician assistants. The two groups were of similar age (E = 57.5, S = 58.2, p= 0.579) and had a similar rate of previous abdominal surgery (E = 51.2%, S = 45.0%, p= 0.428) or hysterectomy (E = 34.2%, S = 26.3%, p= 0.274). Depth of insertion of the scope was 54.5 cm (+/-9.2 cm) with the E and 51.6 cm (+/- 10.3 cm) with the S (p= 0.058). Polyps were found more frequently in the study group (18.3%) compared with the control group (p= 10.2%) though this did not reach statistical significance (p= 0.131). Overall satisfaction with FS was similar in both groups (p= 0.694) but pain and discomfort were less in the patients undergoing FS using the E (p= 0.006). Controlling for age and previous surgery the differences in pain scores remained significant (p= 0.035). Endoscopist assessment of procedure difficulty (p= 0.726) and complication rates (p= 0.614) was equivalent. Controlling for the presence of polyps, the total duration for the procedure was 7.2 min in the E group and 5.7 min in the S group (p= 0.008). There were no significant differences between women with and without hysterectomy on either overall satisfaction or pain and discomfort. CONCLUSION Screening FS in women using an upper endoscope is a feasible approach to colorectal cancer screening. Patients screened with an upper endoscope reported less pain and discomfort compared to standard sigmoidoscope while overall satisfaction did not differ. The trend toward increased polyp detection in patients undergoing FS with an upper endoscope may be related to a more thorough examination due to less patient discomfort and/or an increased depth of insertion of the upper endoscope. Thinner, more flexible endoscopes should be considered when performing screening FS in women.
Collapse
Affiliation(s)
- Francis A Farraye
- Section of Gastroenterology, Boston University Medical Center, Boston, Massachusetts 02118, USA
| | | | | | | | | | | |
Collapse
|
44
|
Raju GS, Rex DK, Kozarek RA, Ahmed I, Brining D, Pasricha PJ. A novel shape-locking guide for prevention of sigmoid looping during colonoscopy. Gastrointest Endosc 2004; 59:416-419. [PMID: 14997146 DOI: 10.1016/s0016-5107(03)02709-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Looping of the endoscope in the sigmoid colon and other colonic segments often represents a significant challenge to the performance of comfortable, complete, and swift colonoscopy. This report describes the design and operation of a new device that addresses this problem, together with preliminary preclinical experience with this use of this shape-locking guide (SG-1). METHODS The shape-locking guide is an overtube that can be converted from a flexible to a rigid configuration on demand. When in the rigid configuration, the shape-locking guide is designed to protect the colon wall from lateral forces exerted by the colonoscope. The shape-locking guide was evaluated in vitro by using an artificial colon model to learn how to operate it, and to assess feasibility for prevention of colon looping. In addition, safety was assessed in vivo in a pig model. RESULTS In vitro, the shape-locking guide prevented colonic looping and, thereby, aided completion of "colonoscopy" in the artificial colon model. Subsequent in vivo studies demonstrated that use of the shape-locking guide is safe and feasible; it performed well with respect to ease of insertion and avoidance of sigmoid looping. There was no evidence of significant injury to the colon or adjacent abdominal viscera. CONCLUSIONS This preliminary study shows that use of the shape-locking guide is safe and that it has performance characteristics that may assist the performance of colonoscopy. Human trials are being undertaken.
Collapse
Affiliation(s)
- Gottumukkala S Raju
- Center for Endoscopic Research Training and Innovation, University of Texas Medical Branch, Galveston, Texas 77555-0764, USA
| | | | | | | | | | | |
Collapse
|
45
|
Taylor SA, Halligan S, Saunders BP, Bassett P, Vance M, Bartram CI. Acceptance by patients of multidetector CT colonography compared with barium enema examinations, flexible sigmoidoscopy, and colonoscopy. AJR Am J Roentgenol 2003; 181:913-21. [PMID: 14500202 DOI: 10.2214/ajr.181.4.1810913] [Citation(s) in RCA: 92] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE The purpose of this study was to compare patient acceptance of multidetector CT colonography, total colonoscopy, flexible sigmoidoscopy, and double-contrast barium enema to ascertain any overall preference. SUBJECTS AND METHODS. One hundred sixty-eight patients underwent CT colonography followed by either flexible sigmoidoscopy (n = 59) or colonoscopy (n = 109). A 25-point questionnaire with principal components relating to satisfaction, worry, and physical discomfort was administered after CT colonography and after endoscopy, and a follow-up questionnaire was administered 1 week after the procedures. Questionnaires were also completed by 140 patients undergoing double-contrast barium enema examinations. Responses were compared using Wilcoxon's matched pairs test and the Mann-Whitney test. RESULTS Overall satisfaction was greater with colonoscopy (p = 0.01), but CT colonography caused less discomfort (p = 0.002), was better tolerated (p = 0.005), and was the preferred follow-up investigation of those expressing a preference (p = 0.003). Compared with flexible sigmoidoscopy, CT colonography caused less pain (p = 0.004), was more acceptable (p = 0.04), and was preferred as the follow-up investigation (p < 0.001). Tolerance of colonoscopy was significantly less in women (p = 0.03), but such was not the case for CT colonography (p = 0.58). Patients undergoing CT colonography were less worried (p < 0.001), were more satisfied (p = 0.001), and suffered less discomfort (p < 0.001) than those having barium enema. CONCLUSION Patients' experiences with barium enema examinations were significantly worse than with any other test. Although patients were most satisfied with colonoscopy, they reported more pain during both colonoscopy and sigmoidoscopy than during CT colonography, and they also found CT more acceptable. In patients expressing a preference, CT colonography was the preferred follow-up investigation.
Collapse
Affiliation(s)
- Stuart A Taylor
- Department of Intestinal Imaging, Intestinal Imaging Centre, Level 4V, St. Mark's Hospital, Watford Rd., Northwick Park, London HA1 3UJ, United Kingdom
| | | | | | | | | | | |
Collapse
|
46
|
Affiliation(s)
- Gregory G Ginsberg
- University of Pennsylvania School of Medicine, Gastroenterology Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| |
Collapse
|
47
|
Adams C, Cardwell C, Cook C, Edwards R, Atkin WS, Morton DG. Effect of hysterectomy status on polyp detection rates at screening flexible sigmoidoscopy. Gastrointest Endosc 2003; 57:848-53. [PMID: 12776031 DOI: 10.1016/s0016-5107(03)70019-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Flexible sigmoidoscopy with polypectomy reduces the incidence of colorectal cancer by removal of premalignant lesions. Factors that reduce the area examined by flexible sigmoidoscopy may reduce its benefit. The aim of this study was to determine whether hysterectomy affects completion and polyp detection rates at flexible sigmoidoscopy. METHODS Within the setting of a multicenter, prospective, controlled trial of screening flexible sigmoidoscopy, patient and examination variables were compared by appropriate statistical methods for women between the ages of 55 and 64 years with and without a history of a hysterectomy. RESULTS One quarter of women participants had undergone a hysterectomy. These women were more likely to have incomplete examinations (risk ratio [RR] of incomplete examination, 1.53; 95% CI [1.4, 1.6]). Flexible sigmoidoscopy was more difficult (p < 0.001), more painful (p < 0.001), and less extensive (46 cm vs. 48 cm insertion on average; p < 0.0001) in women who had undergone a hysterectomy. There was a significant trend toward lower relative detection rates of polyps and adenomas at more proximal sites (rectum, sigmoid colon, and proximal to sigmoid; respectively, p = 0.008, p = 0.009) in this group. CONCLUSIONS Women who have undergone a hysterectomy have less extensive flexible sigmoidoscopy examinations, which are more difficult and more painful, than women without a hysterectomy. Hysterectomy is associated with a reduction in polyp detection rate in the sigmoid colon. This modality of screening may be less effective in women who have undergone a hysterectomy.
Collapse
Affiliation(s)
- Clare Adams
- Department of Surgery, University of Birmingham, UK
| | | | | | | | | | | |
Collapse
|
48
|
|