Table 3 The Yamane technique: Advantages, limitations, and key technical challenges of the Yamane scleral-fixated intraocular lens technique
| Category | Details |
| Advantages | Sutureless - eliminates suture degradation, erosion, and late dislocation |
| Minimal conjunctival manipulation preserves tissue | |
| Shorter operative time vs sutured fixation | |
| Small incision (30-gauge needles), self-sealing sclerotomies | |
| Good IOL centration and axial stability | |
| Posterior chamber positioning maintains normal anatomy | |
| Comparable or superior outcomes vs sutured fixation | |
| Cost-effective (no sutures, fewer reoperations) | |
| Mechanical stability via intrascleral friction + flanges | |
| Reproducible with standardized steps | |
| Limitations | Significant learning curve requiring precise coordination |
| Refractive predictability less precise than in-the-bag IOL | |
| Requires specific three-piece IOLs with appropriate haptic material (e.g., PMMA or PVDF) | |
| Limited options for premium IOLs | |
| Risk of tilt/decentration with asymmetric placement | |
| Haptic deformation risk during externalization | |
| Not ideal for very thin sclera (high myopia, Marfan) | |
| Higher CME rates than sutured techniques | |
| Potential late haptic exposure if inadequately buried | |
| Limited long-term data beyond 5 years | |
| Often benefits from a complete vitrectomy | |
| Key technical challenges | Symmetric and precise scleral tunnel creation |
| Controlled haptic capture within the needle lumen | |
| Symmetric beveled entry to prevent lens tilt | |
| Uniform flange and haptic formation to promote lens centration | |
| Adequate burial of flanged ends to prevent erosion or migration | |
| Assessment of lens centration intraoperatively with irregular pupils |
- Citation: Usta Küçükbezirci G, Gürcan B, Patel N, Ramsey DJ, Alwreikat A. Standardizing the Yamane flanged intrascleral haptic fixation: A framework for efficacy, complication mitigation, and reproducible training. World J Methodol 2026; 16(3): 120949
- URL: https://www.wjgnet.com/2222-0682/full/v16/i3/120949.htm
- DOI: https://dx.doi.org/10.5662/wjm.120949