Copyright: ©Author(s) 2026.
World J Transl Med. Nov 28, 2026; 12(4): 126251
Published online Nov 28, 2026. doi: 10.5528/wjtm.126251
Published online Nov 28, 2026. doi: 10.5528/wjtm.126251
Table 1 Study characteristics of included publications
| Ref. | Year | n | Source/side | RT technique | DIBH system | Total dose | IMN | Key findings |
| Lee et al[12] | 2026 | 32 | Right-sided | IMRT vs VMAT | RPM | 40 Gy/15 F | No | DIBH improves OAR sparing; IMRT lowest heart dose |
| Jiang et al[9] | 2026 | 33 | Right-sided | IMRT | OSMS | 57.50 Gy/25 F; 50 Gy/25 F | Yes | Significant heart, RCA, liver, lung reductions |
| Semiz et al[11] | 2025 | 40 | Right-sided | 3D-CRT/IMRT/VMAT | RPM | 50 Gy/25 F | No/Yes | RCA reduction significant only with RNI |
| Mader et al[5] | 2024 | 16 | Right-sided | IMRT | RPM | 40.05 Gy/15 F; 42.72 Gy/16 F | No | Contra breast Dmax increased; liver Dmax 40.3-17.5 |
| Gough et al[10] | 2024 | 14 | Right-sided | IMRT | RPM | 50 Gy/25 F | No | RCA dose reduction; MLD diff 2.8 Gy |
| Lai et al[16] | 2023 | 31 | Right-sided | VMAT | OSMS | 57.50 Gy/50 F | Yes | SGRT-DIBH protects heart, RCA, lung, liver in RNI |
| Loap et al[15] | 2023 | 15 | Right-sided | VMAT | OSMS | 50 Gy/25 F (40.05 Gy/15 F) | No | Liver dose reduced; heart/coronary NS |
| Peters et al[8] | 2022 | 54 | Right-sided | 3D-CRT | OSMS | 40.05-50 Gy/15-25 F; 46-50 Gy (IMN) | Yes | Largest RNI; all lung/Liver improved; heart NS |
| Demiral et al[14] | 2021 | 36 | Right-sided | IMRT | ABC | 50 Gy/25 F; 60 Gy/30 F (boost) | No | Liver -61%, lung |
| Haji et al[6] | 2019 | 20 | Right-sided | 3D-CRT | OSMS | 50 Gy/25 F | No | DIBH reduces liver, lung, heart |
| Conway et al[7] | 2017 | 30 | Right-sided | IMRT | OSMS | 50 Gy/25 F; 45 Gy/25 F | No | 70% achieved ≥ 5% V20 reduction |
| Essers et al[13] | 2016 | 14 | Right-sided | 3D-CRT | RPM | 42.56 Gy/16 F | Yes/No | Lung reduction only with IMN |
| Browne et al[29] | 2020 | 31 | Mixed L/R | 3D-CRT | ABC | 50 Gy/25 F; 42.5 Gy/16 F | Partial | No independent R-sided data |
| Mankinen et al[19] | 2025 | 25 | Left-sided (sim) | VMAT | RPM | 40.05 Gy/15 F | No | DIR shows DVH subtraction overestimates lung benefit |
| Holt et al[21] | 2021 | 10 | Left-sided (sim) | VMAT vs t-IMRT | RPM | 50 Gy/25 F | No | VMAT: Heart P = 0.53; recommends DIBH + VMAT |
| Pandeli et al[20] | 2019 | 20 | Left-sided (sim) | IMRT | RPM | 40 Gy/15 F | Yes | Benefits most with RNI; simulated |
| Li et al[18] | 2024 | 313 | Meta-analysis | Mixed | ABC/OSMS/RPM | 40-50 Gy | Various | Pooled SMD favors DIBH for heart, liver, lung |
- Citation: Chen WY, Gan ZY, Cai YW, Hua ZQ, Yi L. Advances in deep inspiration breath-hold technique for radiotherapy of right-sided breast cancer. World J Transl Med 2026; 12(4): 126251
- URL: https://www.wjgnet.com/2220-6132/full/v12/i4/126251.htm
- DOI: https://dx.doi.org/10.5528/wjtm.126251