BPG is committed to discovery and dissemination of knowledge
Meta-Analysis
©Author(s) (or their employer(s)) 2026.
World J Crit Care Med. Mar 9, 2026; 15(1): 113426
Published online Mar 9, 2026. doi: 10.5492/wjccm.v15.i1.113426
Table 1 Summary of studies comparing point of care ultrasound to standard imaging modalities
Ref.
Year of publication
Country of study
Study design and setting
Number of patients enrolled
Summary of the patient population
Intervention used
Comparison used
Definition of outcome measured
Number of patients who achieved the outcome in the intervention group
Number of patients who achieved the outcome in the comparison group
Özkan et al[25]2015TurkeyRCT63Patients presenting with dyspnoea in the emergency departmentPOCUS performed by emergency medicine specialistsTraditional stethoscope examinationDiagnostic performance in identifying causes of dyspnoeaFirst diagnosis is compatible with final diagnosis: 18First diagnosis is compatible with final diagnosis: 19
Pontis et al[26]2018FranceRCT107Acute dyspnoeic patientsLung ultrasoundClinical data without LUSDiagnostic accuracy and the number of uncertain diagnoses when using LUS compared to clinical dataNumber of uncertain diagnoses mean: 2.2 ± 1.7Number of uncertain diagnoses mean: 2.9 ± 1.8
Zare et al[2]2022IranRCT103Patients with undifferentiated acute dyspnoeaPOCUS performed by emergency specialistsStandard diagnostic approach without POCUSImpact of POCUS on early patient disposition decisions in the EDMean time of diagnosis 42.61 minutesMean time of diagnosis 79.33 minutes
Baker et al[27]2020AustraliaRCT442Patients aged over 60 years presenting with dyspnoeaPOCUS performed by non-expert clinicians after brief trainingStandard diagnostic assessment without the use of LUS(1) Accurate diagnosis of pulmonary oedem; and (2) Length of ED stayCorrect diagnosis 60 out of 68Correct diagnosis 53 out of 64
Beyer et al[7]2021United StatesMulticentre, prospective, cohort study156Patients with undifferentiated dyspnoeaPOCUS by trained EDPOCUS performed by USS teamEffectiveness of POCUS in narrowing diagnostic uncertainty in dyspnoeic patientMost likely diagnosis changed in 40%Diagnosis changed in 32%
Baid et al[3]2022IndiaProspective observational study237Patients presenting with acute dyspnoeaPOCUS performed by emergency physiciansFinal composite diagnoses made by two emergency medicine consultantsTo determine the diagnostic accuracy of POCUS in various causes of acute onset dyspnoeaMedian time for diagnosis 16 minutesMedian time for diagnosis 170 minutes
Pivett et al[28]2015ItalyMulticenter, prospective cohort study1005Patients presenting to the ED with acute dyspnoeaLUSInitial assessment, CXR and BNPDiagnostic accuracy of LUS compared to CXRSensitivity 97%; specificity 97.4%CXR: Sensitivity 69.5%; specificity 82.1%; BNP sensitivity 75% specificity 61.7%
Nakao et al[29]2021CanadaProspective diagnostic accuracy study324Patients with SOB and cough suspected to be COVID or COPDPOCUSPatients not evaluated by POCUSED length of stay and time to treatmentTime to treatment 61 minutesTime to treatment 92 minutes
Mantuan et al[30]2016United StatesProspective observational study57Patients presenting with acute dyspnoeaTriple scan (LUS, Echo and IVC)Clinical assessmentCompare diagnostic accuracy before and after TSDiagnostic accuracy 77%Diagnostic accuracy 53%
Papanagnou et al[4]2017United StatesProspective observational study115Adult patients with undifferentiated dyspnoeaBedside USSDiagnosis before USS(1) Post-ultrasound diagnoses matched final diagnoses; (2) Frequency ultrasound altered providers’ leading diagnoses; and (3) Change in physicians’ diagnostic confidenceMatched final diagnosis 63% of the timeMatched final diagnosis 69% of the time
Buhumaid et al[16]2019United StatesProspective observational study128Patients presenting with CP and SOB to EDPOCUSCXR(1) How use POCUS in ED differentials; and (2) Evaluate accuracy of POCUS vs CXRPOCUS sensitivity 89%. Specificity 74%CXR sensitivity 38%. Specificity 96%
Núñez-Ramos et al[31]2024ColombiaAnalytical cross-sectional study209Patients with dyspnoea, suspected ACS, HF, shock and/or HTNPOCUSFinal diagnosisEvaluate initial POCUS diagnosis with the diagnosis on dischargeDiagnostic accuracy: HF 99, ACS 98, Shock 98
Pirozzi et al[6]2014ItalySingle center randomized prospective study168Patients presenting with undifferentiated dyspnoeaPOCUS and routine laboratoryUSS in 1 hourDiagnostic accuracy by using POCUS(1) Diagnostic concordance 0.94; and (2) Wrong initial diagnosis 5%(1) Diagnostic concordance 0.22; and (2) Wrong initial diagnosis 50%
Martindale et al[32]2013United StatesProspective, blinded, observational study20Resident physicians in ED, IM and radiologyLUSCXRTo evaluate the ability of residents to recognize pulmonary oedema on LUSSensitivity 99%. Specificity 61%Sensitivity 97%. Specificity 32%
Sharma et al[1]2025IndiaProspective cohort study104Patients presenting with acute shortness of breathBedside LUS, NT-pro BNP, and clinical parametersClinical assessment using modified Boston criteria and NT-pro BNP levels aloneAccuracy of LUS/Pro BNP in differentiating pulmonary from cardiac causes of SOBLUS sensitivity of 100%, specificity of 62.3%NT-pro BNP 100% sensitivity, 91.8% specificity 100%
Bitar et al[33]2015KuwaitA prospective observational study61Patients presenting with symptoms and signs of pulmonary oedemaLUS and EchoBNP levelsDiagnostic accuracy of LUS and Echo in pulmonary oedemaSensitivity 92%. Specificity 90.9%Sensitivity 97.9%. Specificity 71.4%
Zare et al[2]2022IranProspective multicentre study103Patients with acute undifferentiated dyspnoeaEarly POCUS in EDRoutine USSEvaluate the role of bedside USS to identify the cause of undifferentiated dyspnoea and faster disposition in EDMean randomization-to-diagnosis time 4261 minutes79.33 minutes
Umuhire et al[5]2019RwandaProspective observational study99Patients presenting with dyspnoeaMulti-organ POCUS scansPre- and post-ultrasound clinical assessmentsChanges in leading diagnosis and diagnostic accuracyLeading diagnosis matched the final discharge diagnosis in 89% of casesLeading diagnosis matched the final discharge diagnosis in 34.3% of cases
Sartini et al[34]2017ItalyProspective study236Patients presenting with acute dyspnoeaLUS performed to diagnose acute HFDiagnostic accuracy of LUS compared with CXR and NT-pro BNP levelsAccuracy of LUS, CXR, and NT-pro BNP in the early diagnosis of AHFSensitivity 57.73%. Specificity 87.97%CXR: 74.49%, 86.26. BNP 97.59%, 27.56
Yahia et al[35]2022EgyptProspective observational study47Patients presenting with dyspnoea and symptoms suggestive of AHFLUSPlasma Pro BNPAccuracy and usefulness of LUS in assessmentSensitivity of 91.9%. Specificity of 100%Sensitivity of 100%, specificity of 60%
Secko et al[36]2022United StatesProspective observational study102Patients with undifferentiated dyspnoeaBedside LUSPhysical examinationDiagnostic accuracy of LUS vs physical examinationAccuracy is the same for CPD and asthma. LUS more accurate in pneumonia, pulmonary oedema and effusionAccuracy is the same for CPD and asthma. LUS more accurate in pneumonia, pulmonary oedema and effusion
Pivetta et al[28]2019ItalyRCT518Patients with acute dyspnoeaLung ultrasound was integrated with clinical assessmentCXR and BNPAccuracy and utility of combining LUS/clinical assessment vs CXR/BNPDiagnostic accuracy AUC 0.95AUC 0.78
Arvig et al[37]2023DenmarkRCT206Patients presented with dyspnoeaPOCUS within 1 hour of arrival plus two additional POCUSA single POCUS within 1 hour of arrivalA reduction of dyspnoea measured on a verbal dyspnoea scaleThe mean difference in VDS -1.09The mean difference in VDS -1.66
Sorlini et al[38]2021ItalySingle retrospective study384Patients with symptoms and signs of respiratory infectionPOCUS performed at the time of admission or shortly afterwardsCXRAssess diagnostic accuracy of POCUSSensitivity 92% CXR 64.9%Sensitivity 73.9%. Specificity 55.9%
Gibbons et al[39]2021United StatesProspective cohort study110Patients presenting with symptoms of COVID19Portable LUS, CXR and CT (if abnormal)CXR and CTCompare test characteristics of LUS and CXR in COVID19LUS sensitivity 97.6%. Specificity 33.3%CXR sensitivity 96.9%. Specificity 44.4%
Bianchi et al[40]2022ItalyProspective cohort study360Patients with symptoms suggestive of COVID-19POCUS by emergency physicianCT and PCRAnalyse diagnostic power of POCUS for COVID19Sensitivity 86%, specificity 70%, accuracy 77%CXR (sensitivity 64.9%, specificity 88.5% and accuracy 79.6%) BNP (sensitivity 80%, specificity 69.7% and accuracy 75%)
Carlino et al[41]2009ItalyProspective cohort study100Patients presenting with acute dyspnoeaIntegrated ultrasound examinationCXR and BNPTo identify accuracy of an integrated ultrasound approach for diagnosis of acute heart failureSensitivity 100%, specificity 82% and accuracy 89%CXR (sensitivity 64.9%, specificity 88.5% and accuracy 79.6%) BNP (sensitivity 80%, specificity 69.7% and accuracy 75%)
Sforza et al[42]2017ItalyDiagnostic accuracy study68Patients presenting with acute dyspnoea to EDMulti-organ ultrasound using a pocket-sized ultrasound deviceCXRTo test the usefulness and accuracy of multi-organ USSSensitivity 92.6, specificity 80.5% and accuracy 85.3%CXR (sensitivity 75%, specificity 85.4% and accuracy 82%)
Wooten et al[43]2019United StatesProspective observational cohort study99Patients presenting with dyspnoea to EDBedside LUSCXRAssess accuracy of LUS and CXR in pulmonary oedemaSensitivity 96%, specificity 90%Sensitivity 65%. Specificity 95%


Write to the Help Desk