©The Author(s) 2025.
World J Orthop. Oct 18, 2025; 16(10): 110461
Published online Oct 18, 2025. doi: 10.5312/wjo.v16.i10.110461
Published online Oct 18, 2025. doi: 10.5312/wjo.v16.i10.110461
Figure 4 Deformity can be the result of improper reduction or physeal growth arrest (traumatic and iatrogenic).
A: A 7-year-old male with a Gartland type III supracondylar humeral fracture; B: Open reduction via lateral approach and stabilization by 3 Lateral K-wires with incomplete reduction on axial and sagittal level; C and D: In 9-year follow-up there is significant (28°) valgus deformity marked on X-rays (in comparison with the contralateral elbow); E: Elbow range of motion is normal during physical examination.
- Citation: Athanaselis ED, Metaxiotis N, Rigopoulos N, Hantes M, Dailiana ZH, Karachalios T, Varitimidis S. Open reduction can be a reasonable, safe and effective choice in complex paediatric supracondylar humeral fractures operative treatment. World J Orthop 2025; 16(10): 110461
- URL: https://www.wjgnet.com/2218-5836/full/v16/i10/110461.htm
- DOI: https://dx.doi.org/10.5312/wjo.v16.i10.110461