Table 2 Association of the techniques used and rate of complications (χ2 analysis)
| Trocar | Seldinger | Total | χ2 | P value | ||
| Development of complications | Yes, n | 3 | 10 | 13 | ||
| (%) | 6.1 | 17.9 | 12.4 | |||
| No, n | 47 | 46 | 93 | 3317 | 0.069 | |
| (%) | 93.9 | 82.1 | 87.6 | |||
| Total | n | 50 | 56 | 106 | ||
| (%) | 100 | 100 |
- Citation: Turan HG, Özdemir M, Acu R, Küçükay F, Özdemir FAE, Hekimoğlu B, Yıldırım UM. Comparison of seldinger and trocar techniques in the percutaneous treatment of hydatid cysts. World J Radiol 2017; 9(11): 405-412
- URL: https://www.wjgnet.com/1949-8470/full/v9/i11/405.htm
- DOI: https://dx.doi.org/10.4329/wjr.v9.i11.405