BPG is committed to discovery and dissemination of knowledge
Minireviews
Copyright: ©Author(s) 2026.
World J Radiol. Nov 28, 2026; 18(11): 127776
Published online Nov 28, 2026. doi: 10.4329/wjr.127776
Table 4 Representative studies of computed tomography radiomics for cardiotoxicity and cardiovascular risk prediction
Ref.
Dataset
Target task
Comparator
Key findings and performance
Ansari et al[58], 202554 patients with left-sided breast cancer [retrospective; approximately 25 patients with EF-defined heart failure (46%); 3-year post-treatment assessment]Combined cardiac CT radiomics, dosimetry, and clinical modelingChange in echocardiographic ejection fractionRF model: AUC = 0.98; accuracy = 0.85. No independent external validation; small sample and high-dimensional feature selection.
Long et al[59], 2025125 patients with thoracic malignancies (retrospective; 41 cardiotoxicity cases, 84 noncases; internal train/test split)Pretreatment CT radiomics of 10 cardiovascular structures for prediction of RT-related cardiotoxicityCardiotoxicity defined by serial LVEF and longitudinal strain changesInternal test accuracy = 0.76-0.88 across cardiovascular structures; 5-feature LV model accuracy = 0.88. No independent external validation
Chen et al[60], 2026160 patients with NSCLC (retrospective; 31.9% events); independent prospective validation cohort of 57 patients (29.8% events); 100-iteration internal cross-validation (75%/25%)Whole-heart and cardiac-substructure radiomics, dosiomics, and DVH analysis for prediction of hs-cTnT elevation after RT (≥ 5 ng/L above baseline)Clinical model and conventional DVH parametersInternal cross-validation: Whole-heart radiomics + clinical AUC = 0.67 vs clinical AUC = 0.66; substructure radiomics AUC = 0.57; substructure DVH AUC = 0.71 (95%CI: 0.70-0.73); dosiomics AUC = 0.70. Prospective holdout: DVH AUC = 0.60; dosiomics AUC = 0.56
Shang et al[61], 2022 (general CAD study)1586 patients (90 with ACS, 1496 without events; retrospective case-control study; 3-year follow-up; internal training/test split 3:1)PCAT radiomics for prediction of future ACSConventional plaque score and clinical outcomesInternal test set: PCAT radiomic score AUC = 0.811 vs plaque score AUC = 0.640; integrated score AUC = 0.826. No external validation
Huang et al[62], 2025 (general CAD study)242 patients with CAD (121 MACE events; retrospective; 3-year follow-up; internal training/test split)Lesion-specific vs RCA-based PCAT radiomics for MACE predictionRCA-PCAT model, clinical variables, and observed MACEInternal test set: Lesion-specific PCAT model AUC = 0.838 vs RCA-PCAT model AUC = 0.788; lesion-specific model + clinical variables AUC = 0.877 (95%CI: 0.797-0.957)


Write to the Help Desk