Table 2 Modeling and testing mean error (%) for stopping power ratio
| SPR modeling ME | Total | Lung | Soft | Bone | Testing ME | Total | Soft | Bone |
| TSPR,2,1; Tμmr | -0.01 | 0.00 | -0.01 | 0.00 | -0.59 | -0.32 | -0.98 | |
| TSPRsoft,2,1 bone; Tμmr | 0.00 | 0.00 | 0.00 | 0.00 | -0.70 | -0.50 | -0.98 | |
| TSPR,1,2; Tμm | -0.01 | -0.13 | -0.01 | -0.01 | -0.74 | -0.56 | -1.00 | |
| TSPR,1,2; TμL | 0.04 | -0.02 | 0.07 | -0.02 | 1.02 | -0.73 | 3.46 | |
| Stoichiometric | -0.01 | -0.01 | -0.01 | 0.00 | -1.19 | -1.00 | -1.45 | |
| Taasti | 0.02 | -0.01 | 0.00 | 0.08 | 0.34 | 0.28 | 0.43 | |
| H-S | 0.29 | 0.28 | 0.30 | 0.29 | 0.74 | 0.76 | 0.71 | |
| TSPR,2,1; Tμmr 4 g | 0.01 | 0.00 | 0.02 | 0.00 | -0.51 | -0.18 | -0.98 |
- Citation: Chika CE. Generalized multi-energy model for computing radiation treatment parameters on image domain and automated model-selection framework. World J Radiol 2026; 18(10): 126287
- URL: https://www.wjgnet.com/1949-8470/full/v18/i10/126287.htm
- DOI: https://dx.doi.org/10.4329/wjr.126287