Table 12 Modeling and testing maximum absolute error (%) for effective atomic number
| Zef modeling MaxAE | Total | Lung | Soft | Bone | Testing MaxAE | Total | Soft | Bone |
| TZ,2,0; Tμmr | 18.39 | 0.24 | 18.39 | 1.19 | 29.28 | 29.28 | 3.53 | |
| TZ,1,1; Tμm | 10.29 | 0.06 | 10.29 | 0.97 | 19.97 | 19.97 | 4.17 | |
| TB,0,1 | 1.17 | 0.00 | 1.17 | 0.01 | 0.97 | 0.97 | 0.12 | |
| H-S | 9.64 | 0.00 | 1.10 | 9.64 | 10.54 | 1.99 | 10.54 | |
| TZ,2,0; Tμmr 4 g | 6.32 | 0.24 | 6.32 | 1.19 | 11.04 | 11.04 | 3.53 |
- Citation: Chika CE. Generalized multi-energy model for computing radiation treatment parameters on image domain and automated model-selection framework. World J Radiol 2026; 18(10): 126287