Copyright: ©Author(s) 2026.
World J Radiol. Oct 28, 2026; 18(10): 126287
Published online Oct 28, 2026. doi: 10.4329/wjr.126287
Published online Oct 28, 2026. doi: 10.4329/wjr.126287
Table 1 Modeling and testing root mean square error (%) for stopping power ratio
| SPR modeling RMSE | Total | Lung | Soft | Bone | Testing RMSE | Total | Soft | Bone |
| TSPR,2,1; Tμmr | 0.85 | 0.00 | 1.03 | 0.40 | 2.69 | 2.72 | 2.65 | |
| TSPRsoft,2,1 bone; Tμmr | 0.73 | 0.00 | 0.87 | 0.40 | 2.63 | 2.62 | 2.65 | |
| TSPR,1,2; Tμm | 0.76 | 0.13 | 0.90 | 0.42 | 2.66 | 2.66 | 2.65 | |
| TSPR,1,2; TμL | 0.83 | 0.02 | 0.96 | 0.53 | 7.26 | 3.42 | 10.49 | |
| Stoichiometric | 0.93 | -0.01 | 1.10 | 0.56 | 3.40 | 3.38 | 3.42 | |
| Taasti | 0.15 | 0.01 | 0.15 | 0.15 | 0.67 | 0.76 | 0.60 | |
| H-S | 0.39 | 0.28 | 0.41 | 0.35 | 0.85 | 0.91 | 0.77 | |
| TSPR,2,1; Tμmr 4 g | 0.69 | 0.00 | 0.81 | 0.40 | 2.37 | 2.14 | 2.65 |
- Citation: Chika CE. Generalized multi-energy model for computing radiation treatment parameters on image domain and automated model-selection framework. World J Radiol 2026; 18(10): 126287
- URL: https://www.wjgnet.com/1949-8470/full/v18/i10/126287.htm
- DOI: https://dx.doi.org/10.4329/wjr.126287