Retrospective Study
Copyright ©The Author(s) 2025.
World J Radiol. Jun 28, 2025; 17(6): 104473
Published online Jun 28, 2025. doi: 10.4329/wjr.v17.i6.104473
Figure 1
Figure 1 A 59-year-old man experiencing cardiac arrest during running is diagnosed with coronary vasospasm. A: T1 mapping shows an elevated T1 value of 1127 ms at the midventricular septum; B: Non-ischemic late gadolinium enhancement is observed at the basal septum (arrows). This patient has experienced non-sustained ventricular tachycardia 9 times after the installation of an implantable cardioverter defibrillator.