©The Author(s) 2025.
World J Radiol. Dec 28, 2025; 17(12): 112911
Published online Dec 28, 2025. doi: 10.4329/wjr.v17.i12.112911
Published online Dec 28, 2025. doi: 10.4329/wjr.v17.i12.112911
Table 1 Magnetic resonance imaging scan sequences and parameters
| Sequence | Layer thickness (mm) | Field (mm2) | TR/TE (ms) | Flip angle (°) | Matrix size (mm2) |
| RTr Ax fs T2 | 6 | 320 × 320 - 380 × 380 | 2609/97 | 110 | 384 × 384 |
| BH Ax LAVA +C | 5 | 320 × 320 - 360 × 360 | 4/2 | 12 | 224 × 192 |
- Citation: Shi Y, Zhang P, Li L, Yang HM, Li ZM, Zheng J, Yang L. Interpretable model based on multisequence magnetic resonance imaging radiomics for predicting the pathological grades of hepatocellular carcinomas. World J Radiol 2025; 17(12): 112911
- URL: https://www.wjgnet.com/1949-8470/full/v17/i12/112911.htm
- DOI: https://dx.doi.org/10.4329/wjr.v17.i12.112911