©The Author(s) 2025.
World J Radiol. Nov 28, 2025; 17(11): 111651
Published online Nov 28, 2025. doi: 10.4329/wjr.v17.i11.111651
Published online Nov 28, 2025. doi: 10.4329/wjr.v17.i11.111651
Table 3 Median spleen stiffness values
| SWE technique | 2D-QElaXto | 2D-QElaXto | p-QElaXto | p-QElaXto | SSI | SSI |
| Mean spleen stiffness (kPa) | 19.4 | 20.0 | 23.0 | 22.9 | 21.9 | 21.7 |
| Range (kPa) | 9.8-26.7 | 11.7-32.6 | 13.5-46.9 | 13.1-36.1 | 13.4-35.9 | 13.5-33.8 |
| SD | 3.9 | 4.3 | 6.1 | 5.0 | 4.8 | 4.6 |
| 95%CI | 18.27-20.60 | 18.72-21.20 | 21.10-24.86 | 21.45-24.34 | 20.57-23.33 | 20.37-23.04 |
- Citation: Viceconti N, Paratore M, Del Zompo F, Zocco MA, Ainora ME, Esposto G, Gasbarrini A, Pompili M, Riccardi L, Garcovich M. Shear wave elastography in healthy patients: Pancreatic stiffness is less reliable than liver and spleen measurements. World J Radiol 2025; 17(11): 111651
- URL: https://www.wjgnet.com/1949-8470/full/v17/i11/111651.htm
- DOI: https://dx.doi.org/10.4329/wjr.v17.i11.111651