©The Author(s) 2023.
World J Radiol. Jun 28, 2023; 15(6): 157-169
Published online Jun 28, 2023. doi: 10.4329/wjr.v15.i6.157
Published online Jun 28, 2023. doi: 10.4329/wjr.v15.i6.157
Table 2 Magnetic resonance imaging sequences and parameters (3.0 Tesla) for acute pancreatitis
| Sequence | Repetition time (ms) | Echo time (ms) | Slice thickness (mm) | Slice space (mm) | Matrix | Field of view (mm) | Flip angle |
| T1WI | 3.91 | 1.42 | 4.5 | 0 | 304 × 274 | 400 × 300 | 12° |
| T2WI | 8963 | 116.16 | 6 | 20 | 256 × 218 | 380 × 300 | 90° |
| DWI | 3555 | 63.8 | 6.0 | 20 | 128 × 101 | 380 × 300 | 90° |
| MRCP | 6000 | 753.6 | 60 | 0 | 368 × 276 | 300 × 300 | 180° |
| DCE MRI | 3.91 | 1.42 | 4.5 | 0 | 304 × 274 | 400 × 300 | 12° |
- Citation: Song LJ, Xiao B. Acute pancreatitis: Structured report template of magnetic resonance imaging. World J Radiol 2023; 15(6): 157-169
- URL: https://www.wjgnet.com/1949-8470/full/v15/i6/157.htm
- DOI: https://dx.doi.org/10.4329/wjr.v15.i6.157