Table 1 Clinical research on drug - coated balloon angioplasty for coronary small vessel disease
Trial
Intervention
Primary end point
Secondary end point
Follow-up time
TLR/TVR
MACE
LLL
RCT; RVD: < 3.0[9], 2024DCB: 1133; DES: 1139A DoCE (a composite of cardiovascular death, TV-MI, and CPI-TLR)The rates of DoCE at 1 month and 12 months; rates of the individual components of the DoCE (i.e., cardiovascular death, TV-MI, CPI-TLR)2 yearsCPI-TLR: DCB vs DES; 3.1% vs 1.2%; P = 0.0021. CPI-TVR: DCB vs DES; 3.3% vs 1.6%, P = 0.0084At 24 months, the DoCE occurred in 72 (6.4%) in the DCB group and 38 (3.4%) in the DES groupNR
RCT; RVD: 2-2.75[55], 2023DCB: 118; DES: 114The angiographic in-lesion LLLAngiographic success and the absence of in-hospital cardiovascular complications, and MACEs, a composite of cardiac death, all MIs, TLR, and the individual components of MACEs at 1 year and 3 years3 yearsDCB vs DES; 8.8% vs 14.8%; P = 0.18MACE: PCB vs PES; 10.8% vs 20.8%The DCB vs the DES in terms of in-lesion LLL (0.04 ± 0.28 mm vs 0.17 ± 0.39 mm)
RCT; RVD ≤ 2.8[57], 2020PCB: 90; POBA: 45TVFTLR and LLL2 yearsNo significant difference in TVFNRThe PCB vs the POBA in terms of in-lesion LLL (0.01 ± 0.31 mm vs 0.32 ± 0.34 mm)
RCT; RVD < 3[58], 2022DCB: 546; DES: 212MACEsAll-cause death, probable or definite stent thrombosis3 years1 year: No significant difference between DCB and DES; 3 years: Similar major adverse cardiac event ratesThe consistently lower rates of MACE and its components in DCBNR
RCT; RVD < 2.8[59], 2025PCB: 90; PES: 92Angiographic in-stent (or in-balloon) late lumen loss at follow-up angiography at 6 monthsMACE3 years1100 days; TLR: PCB vs PES; 6.7% vs 13%, P = 0.14; TVR: PCB vs PES; 3.3% vs 6.5%, P = 0.321100 days; MACE: PCB vs PES; 14.4% vs 30.4%, P = 0.015NR