Table 2 Transit times, quality of image and relevant endoscopic findings (%)
Group A overnight fast(n = 20)Group B PEG (n = 18)Group C PEG + simethicone(n = 19)P value
GET (min)27.8 ± 27.427.2 ± 35.240.7 ± 32.10.381
SBTT (min)256.4 ± 91256.1 ± 110258.1 ± 1130.998
ICV passing20 (100)16 (88.9)17 (89.5)0.312
Poor cleansing (< 50% )7 (35)3 (16.7)6 (31.6)0.417
Fair cleansing (50%-75%)8 (40)10 (55.6)9 (47.4)0.751
Good cleansing (> 75% although suboptimal)3 (15)2 (11.1)00.522
Excellent cleansing2 (10)3 (16.7)4 (21.1)0.634
“Acceptable” cleansing (includes fair, good or excellent)13 (65)15 (83.3)13 (68.4)0.417
“Adequate” cleansing (includes good or excellent)5 (25)5 (27.8)4 (21.1)0.892
Bubbles10 (50)5 (27.8)3 (15.8)0.065 (A vs C), P = 0.026