Copyright: ©Author(s) 2026.
World J Hepatol. Apr 27, 2026; 18(4): 118038
Published online Apr 27, 2026. doi: 10.4254/wjh.v18.i4.118038
Published online Apr 27, 2026. doi: 10.4254/wjh.v18.i4.118038
Table 4 Summary of findings table for certainty of evidence by Grading of Recommendations, Assessment, Development and Evaluation approach for diagnostic accuracy of blood-based non-invasive tests as a predictor of varices in pediatric portal hypertension
| Diagnostic test for the target condition | No. of studies | Study design | Accuracy parameter | Risk of bias | Indirectness | Inconsistency | Imprecision | Publication bias | Overall certainty of evidence |
| APRI for EV | 7 studies (n = 450) | Cross-sectional | Sensitivity | Serious1 | Not serious | Serious2 | Not serious | None | Low |
| Specificity | Serious1 | Not serious | Not serious | Not serious | None | Moderate | |||
| APRI for CSV | 10 studies (n = 892) | Cross-sectional | Sensitivity | Serious1 | Not serious | Not serious | Serious3 | None | Low |
| Specificity | Serious1 | Not serious | Serious2 | Not serious | None | Low | |||
| Platelet count for EV | 5 studies (n = 368) | Cross-sectional | Sensitivity | Serious1 | Not serious | Serious2 | Not serious | None | Low |
| Specificity | Serious1 | Not serious | Serious2 | Not serious | None | Low | |||
| Platelet count for CSV | 7 studies (n = 612) | Cross-sectional | Sensitivity | Serious1 | Not serious | Not serious | Not serious | None | Moderate |
| Specificity | Serious1 | Not serious | Serious2 | Serious3 | None | Very low | |||
| CPR for EV | 4 studies (n = 320) | Cross-sectional | Sensitivity | Serious1 | Not serious | Not serious | Not serious | None | Moderate |
| Specificity | Serious1 | Not serious | Not serious | Not serious | None | Moderate | |||
| CPR for CSV | 8 studies (n = 624) | Cross-sectional | Sensitivity | Serious1 | Not serious | Serious2 | Serious3 | None | Very low |
| Specificity | Serious1 | Not serious | Serious2 | Not serious | None | Low | |||
| VPR for CSV | 7 studies (n = 655) | Cross-sectional | Sensitivity | Serious1 | Not serious | Not serious | Serious3 | None | Low |
| Specificity | Serious1 | Not serious | Serious2 | Not serious | None | Low | |||
| K-VaPS for CSV | 5 studies (n = 315) | Cross-sectional | Sensitivity | Serious1 | Not serious | Serious2 | Not serious | None | Low |
| Specificity | Serious1 | Not serious | Not serious | Not serious | None | Moderate |
- Citation: Panda K, Dash DP, Pati GK, Maria A, Gautam V. Diagnostic accuracy of blood-based non-invasive tests for prediction of varices in pediatric portal-hypertension: A systematic review and meta-analysis. World J Hepatol 2026; 18(4): 118038
- URL: https://www.wjgnet.com/1948-5182/full/v18/i4/118038.htm
- DOI: https://dx.doi.org/10.4254/wjh.v18.i4.118038