©The Author(s) 2025.
World J Hepatol. Feb 27, 2025; 17(2): 100033
Published online Feb 27, 2025. doi: 10.4254/wjh.v17.i2.100033
Published online Feb 27, 2025. doi: 10.4254/wjh.v17.i2.100033
Table 10 Diagnostic efficacy of sound touch elastography and related techniques (area under the receiver operating characteristic curves for fibrosis detection)
| Ref. | Number of patients | Disease/diagnose | Diagnostic method | Fibrosis stage | AUROC (CI) | Assessment |
| Gatos et al[27] | 152 | CLD | ViTE | F ≥ F1 | 0.9481 | Excellent |
| F ≥ F2 | 0.9698 | Excellent | ||||
| F ≥ F3 | 0.9846 | Excellent | ||||
| F = F4 | 0.9524 | Excellent | ||||
| Yang et al[50] | 106 | CLD | ViTE | F0 vs F1-3 | 0.88 | Good |
| F0-1 vs F2-4 | 0.84 | Good | ||||
| F0-2 vs F3-4 | 0.80 | Acceptable | ||||
| F0-3 vs F4 | 0.80 | Acceptable | ||||
| Yu et al[62] | 85 | T2DM | FibroTouch | ≥ F2 | 0.76 (0.66-0.86) | Acceptable |
| ≥ F3 | 0.81 (0.71-0.91) | Good | ||||
| ≥ F4 | 0.92 (0.85-1.00 | Excellent | ||||
| Qu et al[60] | 237 | NAFLD | FibroTouch | ≥ F2 | 0.71 | Acceptable |
| ≥ F3 | 0.71 | Acceptable | ||||
| F4 | 0.77 | Acceptable |
- Citation: Pozowski P, Bilski M, Bedrylo M, Sitny P, Zaleska-Dorobisz U. Modern ultrasound techniques for diagnosing liver steatosis and fibrosis: A systematic review with a focus on biopsy comparison. World J Hepatol 2025; 17(2): 100033
- URL: https://www.wjgnet.com/1948-5182/full/v17/i2/100033.htm
- DOI: https://dx.doi.org/10.4254/wjh.v17.i2.100033