BPG is committed to discovery and dissemination of knowledge
Observational Study
Copyright: ©Author(s) 2026.
World J Gastroenterol. Jan 21, 2027; 33(3): 125206
Published online Jan 21, 2027. doi: 10.3748/wjg.125206
Figure 4
Figure 4 Calibration and clinical utility assessment of the white-light imaging-based artificial intelligence model for high-grade dysplasia risk prediction. A: Calibration curves of the white-light imaging-based artificial intelligence model in the internal test cohort and two external validation cohorts. The calibration plots demonstrate the agreement between predicted probabilities and observed high-grade dysplasia risks. The diagonal dashed line represents perfect calibration. The corresponding Brier scores were 0.092, 0.081, and 0.082 for the internal test cohort, external validation cohort A, and external validation cohort B, respectively; B: Decision curve analysis of the white-light imaging-based artificial intelligence model across clinically relevant threshold probabilities. The net benefit curves demonstrate the potential clinical utility of the model compared with the strategies of treating all patients and treating none. AUC: Area under the curve.


Write to the Help Desk