Copyright: ©Author(s) 2027.
World J Gastroenterol. Jan 7, 2027; 33(1): 124775
Published online Jan 7, 2027. doi: 10.3748/wjg.124775
Published online Jan 7, 2027. doi: 10.3748/wjg.124775
Table 2 Summary of existing clinical studies across the four major indications
| Ref. | Design | n | Stent type | Key results | Notes |
| PEP prophylaxis | |||||
| Anderloni et al[10], 2020 | Prospective pilot | 38 (9 for PEP) | ARCHIMEDES | 100% technical success | 1 mild PEP; no cholangitis |
| Pérez-Cuadrado Robles et al[15], 2022 | Prospective multicenter feasibility | 53 | ARCHIMEDES | 100% technical; 77.9% clinical success | All AEs mild |
| Maieron et al[16], 2023 | Observational multicenter (Austria) | 60 patients/63 stents | Biodegradable | 94% technical; 90% clinical; no follow-up in 97% | 2 reinterventions |
| McGarrigle et al[14], 2026 | Retrospective multicenter (Australia and New Zealand) | 111 ERCPs | Biodegradable pancreatic | 98% technical; PEP 11% (all mild); AUD $393/patient saving | Preferred by 75% of endoscopists |
| Abbasi et al[17], 2026 | Health-economic model (United Kingdom NHS) | Model-based | Biodegradable pancreatic | Cost-effective; ICER approximately £9317/QALY | Model-based |
| POPF | |||||
| Bakheet et al[19], 2020 | Preclinical (porcine) | Animal | Tubular BDS | Reduced PJ anastomotic stricture | Preclinical |
| Mazzola et al[18], 2022 | Prospective technical series | High-risk PJ | Internal BDS | CR-POPF 13.3% | No significant stent-related complications |
| González-Abós et al[21], 2025 | Propensity-matched cohort | 80 high-risk | Biodegradable | 0% POPF vs 10%; P = 0.039 | Consistent matched/unmatched |
| Farooqui et al[20], 2025 | Systematic review and meta-analysis | 8 studies/155 | Biodegradable | Pooled POPF approximately 7% | Observational only |
| Farooqui et al[22], 2026 | Blinded RCT (interim) | 50 of 310 planned | ARCHIMEDES (fast) | CR-POPF 11.5% vs 25.0% (P = 0.20); biochemical leak 0% vs 12.5% (P = 0.01) | Comparable major complications/mortality |
| PSC/altered anatomy | |||||
| Ponsioen et al[25], 2018 | Multicenter RCT (balloon vs plastic) | 65 | Plastic (comparator) | Equivalent recurrence; higher AEs with stenting (45% vs 6.7%) | Harm of conventional stenting in PSC |
| Lindström et al[24], 2020 | Case series (DBE) | 7 (4 PSC) | ARCHIMEDES | 100% technical; resolution 3/3 anastomotic | 2/4 PSC recurrent cholangitis |
| Bile leaks | |||||
| Laukkarinen et al[26], 2007 | Prospective animal study | Animal | Biodegradable biliary | Reduced drainage; earlier drain removal; no retrieval | Preclinical |
| Siiki et al[23], 2018 | Comparative cohort (3.5 years) | 32 (8 vs 24) | PDX | No repeat endoscopy in BDS; lower total output | Similar 30-day AEs |
| Mohanka et al[29], 2021 | Prospective series (liver transplant) | 20 | ARCHIMEDES | No bile leaks/bilomas/stent-related complications | 1 cholangitis (migration) |
| Salamanca-Bustos et al[30], 2016 | Randomized pilot (LT) | 10 | Biodegradable | 100% patency; no leaks; complete resorption | First RCT pilot |
| Lopez-Lopez et al[31], 2026 | Comparative cohort (LT) | 158 | Self-expandable absorbable | Early biliary complications 2.6% vs 23.8% (P < 0.001); cost €6988 vs €36364 | Propensity-matched |
| Wu et al[28], 2025 | Case series (post-choledochotomy) | 4 | ARCHIMEDES | No complications when positioned; no pancreatitis | Learning curve |
| Venkatachalapathy et al[27], 2025 | Prospective multicenter (United Kingdom/Ireland) | Cohort | ARCHIMEDES | 17-fold QoL improvement; cost saving | Observational |
| Cross-cutting | |||||
| Chen et al[34], 2025 | Systematic review (percutaneous) | 7 studies/323 | Biodegradable biliary | Technical success 98%-100% | Hemobilia most frequent |
| Peristeri et al[35], 2026 | Systematic review (PRISMA) | 15 studies/467 | Biodegradable (mostly PDX) | Technical 99.4%; clinical 73.3% | Cholangitis most frequent; reintervention mostly planned |
| Almeida and Donato[32], 2020 | Systematic review and meta-analysis | Benign strictures | BDS vs multiple plastic | Resolution 83% vs 84%; 1 vs 3 interventions | Cholangitis 24.1% vs 6.1% |
| Dreifuss et al[33], 2025 | Systematic review and meta-analysis | 12 studies/384 | Absorbable biliary | 100% technical; 81% clinical; 3% migration | No mortality |
- Citation: Jan STA, Abbasi A, Menon S. Preventive role of biodegradable pancreatobiliary stents. World J Gastroenterol 2027; 33(1): 124775
- URL: https://www.wjgnet.com/1007-9327/full/v33/i1/124775.htm
- DOI: https://dx.doi.org/10.3748/wjg.124775