Table 1 Parameter comparison of mainstream biodegradable pancreatic and biliary stents
Stent (platform)
Material and design
Diameter
Length
Degradation cycle
Approval scope
Principal indications
ARCHIMEDES BPSPDX (fast and medium variants); alternative polymer (slow variant); helical, dual-channel6-10 Fr40-125 mmFast approximately 12 days; medium approximately 20 days; slow approximately 11 weeksCE-marked (Europe); FDA 510(k) (K243412), July 2025, for pancreatic duct drainagePEP prophylaxis; pancreatic drainage; benign biliary and cystic-duct leaks
UNITY-BBalloon-expandable magnesium alloy, polymer-coated8-10 mmManufacturer rangeApproximately 1-6 monthsCE-marked (Europe); investigational in United StatesBenign biliary strictures
PDX biliary stent (e.g., SX-ELLA-BD)1PDX monofilament, self-expandingApproximately 8-10 mm30-80 mmapproximately 6 months to full resorptionCE-marked (Europe)Benign biliary strictures; percutaneous and endoscopic use