Table 4 Polyp detection rate and adenoma detection rate of the two study arms among high-volume and low-volume endoscopists in the different centers, n (%)
| Detection rate | Centers | LVE | CC | CADe | P value | HVE | CC | CADe | P value |
| Polyp detection rate | Policlinico | 64 (53.8) | 9 (25.7) | 14 (48.3) | 0.06 | 55 (46.2) | 14 (56) | 12 (40) | 0.24 |
| Niguarda | 32 (27.8) | 3 (25) | 6 (30) | 0.76 | 83 (72.2) | 21 (47.7) | 14 (35.9) | 0.28 | |
| FBF | 53 (54.6) | 16 (55.2) | 9 (37.5) | 0.20 | 44 (45.4) | 10 (47.6) | 10 (43.5) | 0.78 | |
| Poliambulanza | 30 (46.2) | 6 (33.3) | 6 (33.3) | 0.36 | 35 (53.8) | 11 (73.3) | 9 (45) | 0.09 | |
| Cattinara | 6 (46.2) | 1 (33.3) | 3 (100) | 0.41 | 7 (53.8) | 2 (66.7) | 2 (50) | 0.66 | |
| Adenoma detection rate | Policlinico | 64 (53.8) | 5 (14.3) | 9 (31) | 0.11 | 55 (46.2) | 8 (32) | 8 (26.7) | 0.67 |
| Niguarda | 32 (27.8) | 3 (25) | 6 (30) | 0.76 | 83 (72.2) | 14 (31.8) | 9 (23.1) | 0.38 | |
| FBF | 53 (54.6) | 13 (44.8) | 6 (25) | 0.13 | 44 (45.4) | 9 (42.9) | 8 (34.8) | 0.58 | |
| Poliambulanza | 30 (46.2) | 4 (22.2) | 5 (41.7) | 0.26 | 35 (53.8) | 11 (73.3) | 7 (35) | 0.03 | |
| Cattinara | 6 (46.2) | 1 (33.3) | 1 (33.3) | 1 | 7 (53.8) | 1 (33.3) | 2 (50) | 0.66 |
- Citation: Tontini GE, Dioscoridi L, Salerno R, Aldinio G, Buonocore MR, Cesaro P, Conforti F, Consonni D, Cottone I, Dabizzi E, Mantia B, Monica F, Mutignani M, Olivari N, Picardi G, Salvi D, Scaramella L, Schettino M, Topa M, Vecchi M, Elli L. Impact of computer-aided polyp detection in screening and diagnostic colonoscopy: A multicenter randomized controlled trial. World J Gastroenterol 2026; 32(29): 116893
- URL: https://www.wjgnet.com/1007-9327/full/v32/i29/116893.htm
- DOI: https://dx.doi.org/10.3748/wjg.116893