Table 1 Trials using computer-aided detection system for colorectal lesions[86-108]
Ref.
Year
Application used
Patients (n)
Findings
Wang et al[86]2019Endo Screener1058AI system significantly increased ADR (29.1% vs 20.3%; P < 0.001)
Su et al[87]2019AQCS623AI significantly increased ADR (28.9% vs 16.5%; P < 0.001)
Liu et al[88]2020Henan Tongyu1026AI significantly increased ADR (39% vs 24%; P < 0.001)
Gong et al[89]2020ENDOANGEL704AI significantly increased ADR (16% vs 8%; P = 0.001)
Repici et al[90]2020GI genius685AI significantly increased ADR (54.8% vs 40.4%)
Wang et al[91]2020Endo Screener369AMR was significantly lower with AI (13.9% vs 40.0%; P < 0.001)
Wang et al[92]2020Endo Screener962AI system significantly increased ADR rather than the sham system (34% vs 28%; P = 0.030)
Kamba et al[93]2021Endo Screener358AMR was significantly lower with AI (13.8% vs 40.6%; P < 0.001)
Xu et al[94]2021Endo Screener2325AI system did not significantly increase PDR (38.8% vs 36.2%; P = 0.183)
Luo et al[95]2021Endo Screener150AI system significantly increased PDR (38.7% vs 34.0%; P < 0.001)
Shaukat et al[96]2022Endo Screener1359AI system significantly increased adenomas per colonoscopy (1.05 vs 0.83; P = 0.002)
Wallace et al[97]2022GI genius230AMR was significantly lower with AI (15.5% vs 32.4%; P < 0.001)
Glissen Brown et al[98]2022Endo Screener223AMR was significantly lower with AI than with high-definition white light colonoscopy (20.12% vs 31.25%; P = 0.025)
Lui et al[99]2023Endo Screener216AI significantly increased ADR in proximal colon (44.7% vs 34.6%)
Ahmad et al[100]2023GI genius614AI system did not significantly increase ADR (71.4% vs 65.0%; P = 0.09)
Mangas-Sanjuan et al[101]2023GI genius3213AI system did not significantly increase advanced colorectal neoplasia detection rate (34.8% vs 34.6%; P = 0.91)
Karsenti et al[102]2023GI genius2015AI system slightly increased ADR (37.5% vs 33.7%; P = 0.051)
Wei et al[103]2023Endo Vigilant769AI system did not significantly increase ADR (35.9% vs 37.2%; P = 0.774)
Nakashima et al[104]2023CAD EYE415AI system significantly increased ADR (59.4% vs 47.6%; P = 0.018)
Gimeno-García et al[105]2024ENDO-AID370AI system significantly increased ADR (55.1% vs 43.8%; P = 0.029)
Yao et al[106]2024ENDOANGEL685AMR was significantly lower with AI (18.82% vs 43.69%; P < 0.001)
Schöler et al[107]2024CAD EYE286AI system did not significantly increase ADR (43% vs 41%; P = 0.696)
Yamaguchi et al[108]2024CAD EYE231AMR was significantly lower with AI (25.6% vs 38.6%; P = 0.033)