World J Gastroenterol. Oct 14, 2025; 31(38): 110999
Published online Oct 14, 2025. doi: 10.3748/wjg.v31.i38.110999
Table 3 Comparative table of the main artificial intelligence models applied to endoscopic diagnosis of esophagitis diagnosis
Model
Training dataset
Population size
Validation status
Key limitations
Methodological rigor
AI-EoE-EREFS (DL/CNN)[48]Endoscopic images, EREFS-labeled, multi-center484 images from 134 patientsRetrospective, some external validationRetrospective data, limited diversity, mainly binary classification, limited real-world scenariosHigh accuracy (AUC = 0.992), but generalizability and real-world robustness uncertain
CNN[47]Endoscopic images (EoE vs controls)1192 characteristic endoscopic images of 108 patientsTested against patients and controlsDataset size not reported, unclear diversity, retrospective designHigh accuracy (95%), but limited transparency and unclear reproducibility
CNN with EREFS integration[49]Endoscopic images annotated with EREFS200 WLIs, including 100 WLIs from EoE patients and 100 WLIs of normal esophagusCompared to human expertsTraining/test data overlap possible, unclear external validationSensitivity improved to 85%, specificity 95% with EREFS
Random decision forest[50]Clinical + endoscopic dataNot specifiedReal-world data, AUC up to 0.94Complexity, integration challenges, population diversity not detailedRobust with multi-source inputs, but needs more transparent validation
General endoscopic AI (DL/CNN)Mixed datasets (WLI, NBI, CT images)Varies; often smallMostly retrospective, single/multi-centerData heterogeneity, lack of multi-center, prospective validationHigh reported accuracy, but shallow validation, risk of bias due to dataset curation