Copyright
©The Author(s) 2025.
World J Gastroenterol. Aug 28, 2025; 31(32): 110573
Published online Aug 28, 2025. doi: 10.3748/wjg.v31.i32.110573
Published online Aug 28, 2025. doi: 10.3748/wjg.v31.i32.110573
Table 6 Interobserver agreement for T-staging assessments between two radiologists for 40-70 keV virtual monoenergetic images and polyenergetic images (n = 157)
Images | T staging | Doctor B | |||||
T1 | T2 | T3-4 | κ | P value | |||
Doctor A | Axial PEIs | T1 | 2 | 0 | 0 | 0.891 | < 0.001 |
T2 | 1 | 29 | 3 | ||||
T3-4 | 0 | 2 | 123 | ||||
OA PEIs | T1 | 2 | 0 | 0 | 0.899 | < 0.001 | |
T2 | 1 | 33 | 2 | ||||
T3-4 | 0 | 3 | 116 | ||||
40 keV OA VMIs | T1 | 15 | 0 | 0 | 0.943 | < 0.001 | |
T2 | 1 | 14 | 2 | ||||
T3-4 | 0 | 0 | 125 | ||||
50 keV OA VMIs | T1 | 13 | 0 | 0 | 0.924 | < 0.001 | |
T2 | 2 | 15 | 2 | ||||
T3-4 | 0 | 0 | 125 | ||||
60 keV OA VMIs | T1 | 4 | 1 | 0 | 0.843 | < 0.001 | |
T2 | 2 | 21 | 3 | ||||
T3-4 | 0 | 2 | 124 | ||||
70 keV OA VMIs | T1 | 3 | 0 | 0 | 0.906 | < 0.001 | |
T2 | 1 | 27 | 3 | ||||
T3-4 | 0 | 1 | 122 |
- Citation: Chen FX, Jiang KK, Zhu JF, Wang MR, Fan XL, Yang JS, He BS. Diagnostic accuracy of dual-layer spectral computed tomography virtual monoenergetic imaging with multiplanar reformation for T-staging of colorectal cancer. World J Gastroenterol 2025; 31(32): 110573
- URL: https://www.wjgnet.com/1007-9327/full/v31/i32/110573.htm
- DOI: https://dx.doi.org/10.3748/wjg.v31.i32.110573