©The Author(s) 2025.
World J Gastroenterol. Aug 28, 2025; 31(32): 110573
Published online Aug 28, 2025. doi: 10.3748/wjg.v31.i32.110573
Published online Aug 28, 2025. doi: 10.3748/wjg.v31.i32.110573
Table 1 Dual-layer spectral computed tomography parameters
| Scan parameters and contrast agent injection protocol | Details |
| Scan parameters | |
| Range | Diaphragmatic dome to the inferior pubic symphysis |
| Tube voltage (kV) | 120 |
| Tube current | Automatic tube current modulation |
| Detector collimation (mm) | 64 × 0.625 |
| Gantry rotation speed (second) | 0.4 |
| Pitch | 1.0 |
| Contrast agent | |
| Concentration (mg/mL) | 350 |
| Dose (mL/kg) | 1.5 |
| Rate (mL/s) | 3.0 |
| Monitoring | |
| Monitoring method | Bolus tracking |
| Monitoring level | Abdominal aorta |
| Monitoring threshold (HU) | 150 |
| Scan phases | Arterial phase, venous phase (delayed by 40 seconds) |
- Citation: Chen FX, Jiang KK, Zhu JF, Wang MR, Fan XL, Yang JS, He BS. Diagnostic accuracy of dual-layer spectral computed tomography virtual monoenergetic imaging with multiplanar reformation for T-staging of colorectal cancer. World J Gastroenterol 2025; 31(32): 110573
- URL: https://www.wjgnet.com/1007-9327/full/v31/i32/110573.htm
- DOI: https://dx.doi.org/10.3748/wjg.v31.i32.110573